Frame slippage verification in stereotactic radiosurgery

被引:19
作者
Otto, K [1 ]
Fallone, BG [1 ]
机构
[1] McGill Univ, Montreal Gen Hosp, Med Phys Unit, Montreal, PQ H3G 1A4, Canada
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1998年 / 41卷 / 01期
基金
英国医学研究理事会;
关键词
radiosurgery; portal; stereotactic; verification; frame slippage;
D O I
10.1016/S0360-3016(98)00005-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To develop a method for detecting frame slippage in stereotactic radiosurgery by interactively matching in three dimensions Digitally Reconstructed Radiographs (DRRs) to portal images. Methods and Materials: DRRs are superimposed over orthogonal edge-detected portal image pairs obtained prior to treatment. By interactively manipulating the CT data in three dimensions (rotations and translations) new DRRs are generated and overlaid with the orthogonal portal images. This method of matching is able to account for ambiguities due to rotations and translations outside of the imaging plane, The matching procedure is performed with anatomical structures, and is used in tandem with a fiducial marker array attached to the stereotactic frame, The method is evaluated using portal images simulated from patient CT data and then tested using a radiographic head phantom. Results: For simulation tests a mean radial alignment error of 0.82 mm was obtained with the 3D matching method compared to a mean error of 3.52 mm when using conventional matching techniques. For the head phantom tests the mean alignment displacement error for each of the stereotactic coordinates was found to be Delta x = 0.95 mm, Delta y = 1.06 mm, Delta z = 0.99 mm, with a mean error radial of 1.94 mm (SD = 0.61 mm). Conclusion: Results indicate that the accuracy of the system is appropriate for stereotactic radiosurgery, and is therefore an effective tool for verification of frame slippage. (C) 1998 Elsevier Science Inc.
引用
收藏
页码:199 / 205
页数:7
相关论文
共 16 条
[1]   LEAST-SQUARES FITTING OF 2 3-D POINT SETS [J].
ARUN, KS ;
HUANG, TS ;
BLOSTEIN, SD .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1987, 9 (05) :699-700
[2]   VARIABLES AFFECTING THE ACCURACY OF STEREOTAXIC LOCALIZATION USING COMPUTERIZED-TOMOGRAPHY [J].
BUCHOLZ, RD ;
HO, HW ;
RUBIN, JP .
JOURNAL OF NEUROSURGERY, 1993, 79 (05) :667-673
[3]  
CADMAN PF, 1992, TARGET LOCALIZATION, P67
[4]   A NOVEL ALGORITHM FOR THE EDGE-DETECTION AND EDGE ENHANCEMENT OF MEDICAL IMAGES [J].
CROOKS, I ;
FALLONE, BG .
MEDICAL PHYSICS, 1993, 20 (04) :993-998
[5]  
GARITY M, 1990, COMPUT GRAPHICS, V24, P35
[6]   Interactive three dimensional inspection of patient setup in radiation therapy using digital portal images and computed tomography data [J].
Gilhuijs, KGA ;
Drukker, K ;
Touw, A ;
vandeVen, PJH ;
vanHerk, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (04) :873-885
[7]   Automatic three-dimensional inspection of patient setup in radiation therapy using portal images, simulator images, and computed tomography data [J].
Gilhuijs, KGA ;
vandeVen, PJH ;
vanHerk, M .
MEDICAL PHYSICS, 1996, 23 (03) :389-399
[8]   OPTIMIZATION OF AUTOMATIC PORTAL IMAGE-ANALYSIS [J].
GILHUIJS, KGA ;
TOUW, A ;
VANHERK, M ;
VIJLBRIEF, RE .
MEDICAL PHYSICS, 1995, 22 (07) :1089-1099
[9]  
HARTMANN GH, 1995, QUALITY ASURANCE PRO
[10]   STEREOTAXIC RADIOTHERAPY TECHNIQUE FOR SMALL INTRACRANIAL LESIONS [J].
HOUDEK, PV ;
FAYOS, JV ;
VANBUREN, JM ;
GINSBERG, MS .
MEDICAL PHYSICS, 1985, 12 (04) :469-472