Cylindrical ion trap array with mass selection by variation in trap dimensions

被引:36
作者
Badman, ER [1 ]
Cooks, RG [1 ]
机构
[1] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
关键词
D O I
10.1021/ac000377n
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A mass spectrometer array is described in which each array element is a cylindrical ion trap (CIT) within which an approximately quadrupolar, time-varying, held is established. The individual traps are of different sizes, so that when the array is operated with a fixed rf potential, ions of different masses (or mass ranges) are stored in each trap. By choosing the dimensions of each CIT element in the array, a multiple ion monitoring experiment can be performed. For example, in a two-element array with elements having internal radii of 5 and 4 mm, the smaller trap selects for mit 91 and the larger for m/z 57, corresponding to characteristic aromatic and aliphatic hydrocarbon ions. Ion storage using both rf/dc (apex) isolation and the stored waveform inverse Fourier transform method is demonstrated. The array reduces the complexity of the electronics needed to operate the ion: trap, which should make it suitable for use in a miniature mass spectrometer system.
引用
收藏
页码:5079 / 5086
页数:8
相关论文
共 86 条
[31]   TANDEM-IN-SPACE AND TANDEM-IN-TIME MASS-SPECTROMETRY - TRIPLE QUADRUPOLES AND QUADRUPOLE ION TRAPS [J].
JOHNSON, JV ;
YOST, RA ;
KELLEY, PE ;
BRADFORD, DC .
ANALYTICAL CHEMISTRY, 1990, 62 (20) :2162-2172
[32]   BROAD-BAND EXCITATION IN THE QUADRUPOLE ION-TRAP MASS-SPECTROMETER USING SHAPED PULSES CREATED WITH THE INVERSE FOURIER-TRANSFORM [J].
JULIAN, RK ;
COOKS, RG .
ANALYTICAL CHEMISTRY, 1993, 65 (14) :1827-1833
[33]   OPERATION OF A QUADRUPOLE ION TRAP MASS-SPECTROMETER TO ACHIEVE HIGH MASS CHARGE RATIOS [J].
KAISER, RE ;
COOKS, RG ;
STAFFORD, GC ;
SYKA, JEP ;
HEMBERGER, PH .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1991, 106 :79-115
[34]   SIMULTANEOUS ISOLATION OF 2 DIFFERENT M/Z IONS IN AN ION-TRAP MASS-SPECTROMETER AND THEIR TANDEM MASS-SPECTRA USING FILTERED-NOISE FIELDS [J].
KENNY, DV ;
CALLAHAN, PJ ;
GORDON, SM ;
STILLER, SW .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (12) :1086-1089
[35]  
Ketola RA, 1998, RAPID COMMUN MASS SP, V12, P1011, DOI 10.1002/(SICI)1097-0231(19980815)12:15<1011::AID-RCM268>3.3.CO
[36]  
2-O
[37]  
Ketola RA, 1999, RAPID COMMUN MASS SP, V13, P654, DOI 10.1002/(SICI)1097-0231(19990430)13:8<654::AID-RCM537>3.0.CO
[38]  
2-I
[39]  
Kirchner N.J, 1993, US Patent, Patent No. 5206506
[40]  
KOFEL P, 1995, PRACTICAL ASPECTS IO, V2, P51