Application-specific sensor systems based on CMOS chemical microsensors

被引:80
作者
Hierlemann, A [1 ]
Lange, D [1 ]
Hagleitner, C [1 ]
Kerness, N [1 ]
Koll, A [1 ]
Brand, O [1 ]
Baltes, H [1 ]
机构
[1] Swiss Fed Inst Technol, Inst Quantum Elect, Phys Elect Lab, CH-8093 Zurich, Switzerland
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2000年 / 70卷 / 1-3期
关键词
chemical microsensor; capacitor; mass-sensitive sensor; resonator; calorimetric sensor; volatile organic compounds; polymers;
D O I
10.1016/S0925-4005(00)00546-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report on results achieved with three different types of polymer-coated chemical microsensors fabricated in industrial CMOS technology followed by post-CMOS anisotropic etching and film deposition. The first and most extensively studied transducer is a microcapacitor sensitive to changes in dielectric properties of the polymer layer upon analyte absorption. An on-chip integrated Sigma Delta -converter allows for detecting the minute capacitance changes. The second transducer is a resonant cantilever sensitive to predominantly mass changes. The cantilever is electrothermally excited; its vibrations are detected using a piezoresistive Wheatstone bridge. In analogy to acoustic wave devices, analyte absorption in the polymer causes resonance frequency shifts as a consequence of changes in the oscillating mass. The last transducer is a microcalorimeter consisting of a polymer-coated sensing thermopile and an uncoated reference thermopile each on micromachined membranes. The measurand is the absorption or desorption heat of organic volatiles in the polymer layer. The difference between the resulting thermovoltages is processed with an on-chip low-noise differential amplifier. Gas test measurements with all three transducer principles will be presented. The goal is to combine the three different transducer principles and vary the polymers in an array type structure to build a new generation of application-specific microsensor systems. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:2 / 11
页数:10
相关论文
共 39 条
  • [1] [Anonymous], 1970, TECHNIQUES CHEM
  • [2] The electronic nose in Lilliput
    Baltes, H
    Lange, D
    Koll, A
    [J]. IEEE SPECTRUM, 1998, 35 (09) : 35 - 38
  • [3] Micromachined thermally based CMOS microsensors
    Baltes, H
    Paul, O
    Brand, O
    [J]. PROCEEDINGS OF THE IEEE, 1998, 86 (08) : 1660 - 1678
  • [4] PHOTOTHERMAL SPECTROSCOPY WITH FEMTOJOULE SENSITIVITY USING A MICROMECHANICAL DEVICE
    BARNES, JR
    STEPHENSON, RJ
    WELLAND, ME
    GERBER, C
    GIMZEWSKI, JK
    [J]. NATURE, 1994, 372 (6501) : 79 - 81
  • [5] AN INTEGRATED SILICON THERMOPILE AS BIOSENSOR FOR THE THERMAL MONITORING OF GLUCOSE, UREA AND PENICILLIN
    BATAILLARD, P
    STEFFGEN, E
    HAEMMERLI, S
    MANZ, A
    WIDMER, HM
    [J]. BIOSENSORS & BIOELECTRONICS, 1993, 8 (02) : 89 - 98
  • [6] Performances of mass-sensitive devices for gas sensing: Thickness shear mode and surface acoustic wave transducers
    Bodenhofer, K
    Hierlemann, A
    Noetzel, G
    Weimar, U
    Gopel, W
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (13) : 2210 - 2218
  • [7] New method of vaporizing volatile organics for gas
    Bodenhofer, K
    Hierlemann, A
    Schlunk, R
    Gopel, W
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1997, 45 (03) : 259 - 264
  • [8] Sensitivity of the electrical admittance of a polysiloxane film to organic vapours
    Casalini, R
    Kilitziraki, M
    Wood, D
    Petty, MC
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1999, 56 (1-2) : 37 - 44
  • [9] ADSORPTION-INDUCED SURFACE STRESS AND ITS EFFECTS ON RESONANCE FREQUENCY OF MICROCANTILEVERS
    CHEN, GY
    THUNDAT, T
    WACHTER, EA
    WARMACK, RJ
    [J]. JOURNAL OF APPLIED PHYSICS, 1995, 77 (08) : 3618 - 3622
  • [10] DICKERT FL, 1993, BER BUNSEN PHYS CHEM, V97, P184