Characterization of long-term femoral-head-penetration rates - Association with and prediction of osteolysis

被引:198
作者
Dowd, JE [1 ]
Sychterz, CJ [1 ]
Young, AM [1 ]
Engh, CA [1 ]
机构
[1] Anderson Orthopaed Res Inst, Alexandria, VA 22307 USA
关键词
D O I
10.2106/00004623-200008000-00006
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: We examined the relationship between long-term femoral-head-penetration patterns and osteolysis in a ten-year follow-up study of a well controlled patient population. The purposes of this study were to characterize the linearity of long-term head-penetration patterns over time, to describe the relationship between ten-year true wear rates and osteolysis, and to determine whether the occurrence of osteolysis at ten years could be predicted by penetration data obtained prior to five years. Methods: Temporal femoral-head-penetration patterns were examined at a minimum of ten years after forty-eight primary total hip arthroplasties. The arthroplasties were performed with the use of an Arthropor acetabular cup (Joint Medical Products) and a thirty-two-millimeter-diameter cobalt-chromium femoral head (DePuy), Using a computer-assisted radiographic technique, we evaluated two-dimensional head penetration on serial annual radiographs. Linear regression analysis modeled penetration-versus-time data as a line for each patient. The slope of the regression line indicated the true wear rate for each patient. In a subgroup of thirty-four hips for which three annual radiographs had been made less than five years after the arthroplasty, we compared early head-penetration patterns with the later occurrence of osteolysis. Results: For all forty-eight hips, the true wear rate averaged 0.18 millimeter per gear (range, 0.01 to 0.44 millimeter per year) and temporal head-penetration patterns tended to be linear (mean r(2) = 0.91 +/- 0.16). Osteolysis at ten years was strongly associated with increasing true wear rates (p < 0.001), Osteolysis did not develop in any of the nine hips with a true wear rate of less than 0.1 millimeter per year. However, osteolysis developed in nine (43 percent) of twenty-one hips,vith a rate between 0.1 and less than 0.2 millimeter per year, in eight of ten hips with a rate between 0.2 and 0.3 millimeter per year, and in all eight hips with a rate of greater than 0.3 millimeter per year. Evaluation of early true wear rates as a predictor of late osteolysis showed a similar relationship. Conclusions: This study demonstrates that true wear rates tend to be constant and that increased true wear is significantly associated with osteolysis at ten years after the operation. A similar relationship was also found at the early follow-up interval, indicating that early true wear rates (determined from serial radiographs) might enable orthopaedists to predict if patients are at risk for the development of osteolysis. Clinical Relevance: On the basis of these findings, we use temporal femoral-head-penetration data in our practice to evaluate polyethylene inserts in asymptomatic patients, to estimate the time to component wear-through, and to adjust the frequency of follow-up evaluations for monitoring the development of osteolytic lesions in at-risk patients.
引用
收藏
页码:1102 / 1107
页数:6
相关论文
共 19 条
[11]
Determination of polyethylene wear in total hip replacements with use of digital radiographs [J].
Martell, JM ;
Berdia, S .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (11) :1635-1641
[12]
Severe osteolysis after third-body wear due to hydroxyapatite particles from acetabular cup coating [J].
Morscher, EW ;
Hefti, A ;
Aebi, U .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (02) :267-272
[13]
NASHED RS, 1995, CLIN ORTHOP RELAT R, V317, P19
[14]
THE RELATIONSHIP BETWEEN THE DESIGN, POSITION, AND ARTICULAR WEAR OF ACETABULAR COMPONENTS INSERTED WITHOUT CEMENT AND THE DEVELOPMENT OF PELVIC OSTEOLYSIS [J].
SCHMALZRIED, TP ;
GUTTMANN, D ;
GRECULA, M ;
AMSTUTZ, HC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (05) :677-688
[15]
Digital edge-detection measurement of polyethylene wear after total hip arthroplasty [J].
Shaver, SM ;
Brown, TD ;
Hillis, SL ;
Callaghan, JJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (05) :690-700
[16]
SUTULA LC, 1995, CLIN ORTHOP RELAT R, P28
[17]
Radiographic evaluation of penetration by the femoral head into the polyethylene liner over time [J].
Sychterz, CJ ;
Engh, CA ;
Shah, N ;
Engh, CA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (07) :1040-1046
[18]
Analysis of temporal wear patterns of porous-coated acetabular components: Distinguishing between true wear and so-called bedding-in [J].
Sychterz, CJ ;
Engh, CA ;
Yang, A ;
Engh, CA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (06) :821-830
[19]