Meniscal wear at a three-component total ankle prosthesis by a knee joint simulator

被引:18
作者
Affatato, S.
Leardini, A.
Leardini, W.
Giannini, S.
Viceconti, M.
机构
[1] Ist Ortoped Rizzoli, Lab Tecnol Med, I-40136 Bologna, Italy
[2] Ist Ortoped Rizzoli, Movement Anal Lab, I-40136 Bologna, Italy
关键词
total ankle replacement; knee wear simulator; meniscal bearing;
D O I
10.1016/j.jbiomech.2006.08.002
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Despite the fundamental value of wear simulation studies to assess wear resistance of total joint replacements, neither specialised simulators nor established external conditions are available for the human ankle joint. The aim of the present study was to verify the suitability of a knee wear simulator to assess wear rates in ankle prostheses, and to report preliminary this rate for a novel three-component total ankle replacement design. Four intact 'small' size specimens of the Box ankle were analysed in a four-station knee wear simulator. Special component-to-actuator holders were manufactured and starting spatial alignment of the three-components was sought. Consistent load and motion cycles representing conditions at the ankle joint replaced exactly with the prosthesis design under analysis were taken from a corresponding mechanical model of the stance phase of walking. The weight loss for the three specimens, after two million cycles, was 32.68, 14.78, and 62.28 mg which correspond to a linear penetration of 0.0 18, 0.008, and 0.034 mm per million-cycle, respectively for the specimens #1, #2, and #3. The knee wear simulator was able to reproduce load-motion patterns typical of a replaced ankle. Motion of the meniscal bearing in between the tibial and talar components was smooth, this component remaining in place and in complete congruence with the metal components throughout the test. (C) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1871 / 1876
页数:6
相关论文
共 47 条
[1]   Mixed oxides prosthetic ceramic ball heads.: Part 3:: effect of the ZrO2 fraction on the wear of ceramic on ceramic hip joint prostheses.: A long-term in vitro wear study [J].
Affatato, S ;
Goldoni, M ;
Testoni, M ;
Toni, A .
BIOMATERIALS, 2001, 22 (07) :717-723
[2]   Fluid absorption study in ultra-high molecular weight polyethylene( UHMWPE) sterilized and unsterilized acetabular cups [J].
Affatato, S ;
Vandelli, C ;
Bordini, B ;
Toni, A .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2001, 215 (H1) :107-111
[3]  
Affatato S, 2000, J BIOMED MATER RES, V53, P221, DOI 10.1002/(SICI)1097-4636(2000)53:3<221::AID-JBM6>3.0.CO
[4]  
2-Z
[5]   Investigation of wear of knee prostheses in a new displacement/force-controlled simulator [J].
Barnett, PI ;
McEwen, HMJ ;
Auger, DD ;
Stone, MH ;
Ingham, E ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2002, 216 (H1) :51-61
[6]  
BAUER G, 1996, FOOT ANKLE SURG, V2, P119, DOI DOI 10.1046/j.1460-9584.1996.00024.x
[7]   Effects of in vitro wear of machined and molded UHMWPE tibial inserts on TKR kinematics [J].
Benson, LC ;
DesJardins, JD ;
LaBerge, M .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2001, 58 (05) :496-504
[8]  
BONNIN M, 2004, CLIN ORTHOP RELAT R, V424, P6, DOI DOI 10.I097/01.BL0.0000132407.75881.A0
[9]   Radiostereometric analysis of the double-coated STAR total ankle prosthesis -: A 3-5-year follow-up of 5 cases with rheumatoid arthritis and 5 cases with osteoarthrosis [J].
Carlsson, Å ;
Markusson, P ;
Sundberg, M .
ACTA ORTHOPAEDICA, 2005, 76 (04) :573-579
[10]   Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements [J].
Clarke, IC ;
Good, V ;
Williams, P ;
Schroeder, D ;
Anissian, L ;
Stark, A ;
Oonishi, H ;
Schuldies, J ;
Gustafson, G .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2000, 214 (H4) :331-347