Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and Approaches

被引:790
作者
Bae, Kyongtae T. [1 ]
机构
[1] Univ Pittsburgh, Sch Med, Dept Radiol, Pittsburgh, PA 15213 USA
关键词
MULTIDETECTOR-ROW CT; ENHANCED SPIRAL CT; DYNAMIC HEPATIC CT; TO-LIVER CONTRAST; PHASE HELICAL CT; BODY-MASS INDEX; HYPERVASCULAR HEPATOCELLULAR CARCINOMAS; DIFFERENT IODINE CONCENTRATIONS; EXPERIMENTAL PORCINE MODEL; BOLUS-TRACKING TECHNOLOGY;
D O I
10.1148/radiol.10090908
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The continuing advances in computed tomographic (CT) technology in the past decades have provided ongoing opportunities to improve CT image quality and clinical practice and discover new clinical CT imaging applications. New CT technology, however, has introduced new challenges in clinical radiology practice. One of the challenges is with intravenous contrast medium administration and scan timing. In this article, contrast medium pharmacokinetics and patient, contrast medium, and CT scanning factors associated with contrast enhancement and scan timing are presented and discussed. Published data from clinical studies of contrast medium and physiology are reviewed and interpreted. Computer simulation data are analyzed to provide an in-depth analysis of various factors associated with contrast enhancement and scan timing. On the basis of basic principles and analysis of the factors, clinical considerations and modifications to protocol design that are necessary to optimize contrast enhancement for common clinical CT applications are proposed. (C) RSNA, 2010
引用
收藏
页码:32 / 61
页数:30
相关论文
共 206 条
[51]   Contrast medium use [J].
Davidson, Charles ;
Stacul, Fulvio ;
McCullough, Peter A. ;
Tumlin, James ;
Adam, Andy ;
Lameire, Norbert ;
Becker, Christoph R. .
AMERICAN JOURNAL OF CARDIOLOGY, 2006, 98 (6A) :42K-58K
[52]   The value of mathematical modelling in understanding contrast enhancement in CT with particular reference to the detection of hypovascular liver metastases [J].
Dawson, P ;
Blomley, M .
EUROPEAN JOURNAL OF RADIOLOGY, 2002, 41 (03) :222-236
[53]   Sixteen-detector row CT angiography of carotid arteries:: Comparison of different volumes of contrast material with and without a bolus chaser [J].
de Monyé, C ;
Cademartiri, F ;
de Weert, TT ;
Siepman, DAM ;
Dippel, DWJ ;
van Der Lugt, A .
RADIOLOGY, 2005, 237 (02) :555-562
[54]  
de Monyé C, 2006, AM J ROENTGENOL, V186, P1737, DOI 10.2214/AJR.05.0143
[55]   HEPATIC CT CONTRAST ENHANCEMENT - EFFECT OF DOSE, DURATION OF INFUSION, AND TIME ELAPSED FOLLOWING INFUSION [J].
DEAN, PB ;
VIOLANTE, MR ;
MAHONEY, JA .
INVESTIGATIVE RADIOLOGY, 1980, 15 (02) :158-161
[56]   Optimizing liver contrast in helical liver CT:: value of a real-time bolus-triggering technique [J].
Dinkel, HP ;
Fieger, M ;
Knüpffer, J ;
Moll, R ;
Schindler, G .
EUROPEAN RADIOLOGY, 1998, 8 (09) :1608-1612
[57]   Using a saline chaser to decrease contrast media in abdominal CT [J].
Dorio, PJ ;
Lee, FT ;
Henseler, KP ;
Pilot, M ;
Pozniak, MA ;
Winter, TC ;
Shock, SA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (04) :929-934
[58]  
Drop Andrzej, 2002, Ann Univ Mariae Curie Sklodowska Med, V57, P39
[59]   Effect of duration of contrast material injection on peak enhancement times and values of the aorta, main portal vein, and liver at dynamic MDCT with the dose of contrast medium tailored to patient weight [J].
Erturk, S. M. ;
Ichikawa, T. ;
Sou, H. ;
Tsukamoto, T. ;
Motosugi, U. ;
Araki, T. .
CLINICAL RADIOLOGY, 2008, 63 (03) :263-271
[60]  
FERRUCCI JT, 1988, RADIOLOGY, V168, P319