Reduction in thrombotic events with heparin-coated Palmaz-Schatz stents in normal porcine coronary arteries

被引:175
作者
Hardhammar, PA
vanBeusekom, HMM
Emanuelsson, HU
Hofma, SH
Albertsson, PA
Verdouw, PD
Boersma, E
Serruys, PW
vanderGiessen, WJ
机构
[1] ERASMUS UNIV ROTTERDAM, THORAXCTR, DEPT CARDIOL, 3015 GD ROTTERDAM, NETHERLANDS
[2] SAHLGRENS UNIV HOSP, DIV CARDIOL, GOTHENBURG, SWEDEN
关键词
stents; thrombosis; heparin;
D O I
10.1161/01.CIR.93.3.423
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The use of stents improves the result after balloon coronary angioplasty. Thrombogenicity of stents is, however, a concern. In the present study, we compared stents with an antithrombotic coating with regular stents. Methods and Results Regular stents were placed in coronary arteries of pigs receiving no aspirin (group 1; n=8) or aspirin over 4 weeks (group 2, n=10) or 12 weeks (group 3, n=9). Stents coated with heparin (antithrombin III uptake, 5 pmol/stent) were placed in 7 pigs that did not receive aspirin (group 4). The other animals received aspirin and coated stents with a heparin activity of 12 pmol antithrombin III/stent (group 5, n=10) or 20 pmol/stent (group 6, n=10; group 7, n=10). Quantitative arteriography was performed at implantation and after 4 (groups 1, 2, and 4 through 6) or 12 weeks (groups 3 and 7). In an additional 5 animals, five regular and five coated stents (20 pmolistent) were placed and explanted after 5 days for examination of the early responses to the implants. Thrombotic occlusion of the regular stent occurred in 9 of 27 in groups 1 through 3. However, in 0 of 30 of the animals receiving high activity heparin-coated stents (groups 5 through 7), thrombotic stent occlusion was observed (P<.001). Histological analysis at 4 weeks showed that the neointima in group 6 was thicker compared with its control group 2 (259+/-104 and 117+/-36 mu m, P<.01), but at 12 weeks the thickness was similar (152+/-61 and 198+/-49 mu m, respectively). Comparison at 5 days suggested delayed endothelialization of the coating. Conclusions High-activity heparin coating of stents eliminates subacute thrombosis in porcine coronary arteries.
引用
收藏
页码:423 / 430
页数:8
相关论文
共 50 条
  • [41] A COMPARISON OF BALLOON-EXPANDABLE-STENT IMPLANTATION WITH BALLOON ANGIOPLASTY IN PATIENTS WITH CORONARY-ARTERY DISEASE
    SERRUYS, PW
    DEJAEGERE, P
    KIEMENEIJ, F
    MACAYA, C
    RUTSCH, W
    HEYNDRICKX, G
    EMANUELSSON, H
    MARCO, J
    LEGRAND, V
    MATERNE, P
    BELARDI, J
    SIGWART, U
    COLOMBO, A
    GOY, JJ
    VANDENHEUVEL, P
    DELCAN, J
    MOREL, MA
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) : 489 - 495
  • [42] CO-IMMOBILIZATION AND INTERACTION OF HEPARIN AND PLASMIN ON COLLAGENO-ELASTIC TUBES
    SHANKAR, H
    SENATORE, F
    WU, DR
    AVANTSA, S
    [J]. BIOMATERIALS ARTIFICIAL CELLS AND ARTIFICIAL ORGANS, 1990, 18 (01): : 59 - 73
  • [43] INTRAVASCULAR STENTS TO PREVENT OCCLUSION AND RESTENOSIS AFTER TRANS-LUMINAL ANGIOPLASTY
    SIGWART, U
    PUEL, J
    MIRKOVITCH, V
    JOFFRE, F
    KAPPENBERGER, L
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1987, 316 (12) : 701 - 706
  • [44] RANDOMIZED TRIAL OF CORONARY INTERVENTION WITH ANTIBODY AGAINST PLATELET IIB/IIIA INTEGRIN FOR REDUCTION OF CLINICAL RESTENOSIS - RESULTS AT 6 MONTHS
    TOPOL, EJ
    CALIFF, RM
    WEISMAN, HF
    ELLIS, SG
    TCHENG, JE
    WORLEY, S
    IVANHOE, R
    GEORGE, BS
    FINTEL, D
    WESTON, M
    SIGMON, K
    ANDERSON, KM
    LEE, KL
    WILLERSON, JT
    SMITH, CR
    WEISMAN, H
    [J]. LANCET, 1994, 343 (8902) : 881 - 886
  • [45] CAVEATS ABOUT ELECTIVE CORONARY STENTING
    TOPOL, EJ
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) : 539 - 541
  • [46] CORONARY STENTING WITH POLYMER-COATED AND UNCOATED SELF-EXPANDING ENDOPROSTHESES IN PIGS
    VANDERGIESSEN, WJ
    VANBEUSEKOM, HMM
    VANHOUTEN, CD
    VANWOERKENS, LJ
    VERDOUW, PD
    SERRUYS, PW
    [J]. CORONARY ARTERY DISEASE, 1992, 3 (07) : 631 - 640
  • [47] CORONARY STENTING WITH A NEW, RADIOPAQUE, BALLOON-EXPANDABLE ENDOPROSTHESIS IN PIGS
    VANDERGIESSEN, WJ
    SERRUYS, PW
    VANBEUSEKOM, HMM
    VANWOERKENS, LJ
    VANLOON, H
    SOEI, LK
    STRAUSS, BH
    BEATT, KJ
    VERDOUW, PD
    [J]. CIRCULATION, 1991, 83 (05) : 1788 - 1798
  • [48] VIDEM V, 1991, J THORAC CARDIOV SUR, V101, P654
  • [49] VONSEGESSER LK, 1991, ASAIO T, V37, P278
  • [50] STABILITY OF THROMBUS-RESISTANT GRAPHITE-BENZALKONIUM-HEPARIN SURFACE IN ANTI-HEPARIN ENVIRONMENT
    WHIFFEN, JD
    GOTT, VL
    YOUNG, WP
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1964, 48 (02) : 317 - &