Reliability and reproducibility of automated contour analysis in intravascular ultrasound images of femoropopliteal arteries

被引:8
作者
van der Lugt, A
Hartlooper, A
van Essen, JA
Li, WG
von Birgelen, C
Reiber, JHC
Gussenhoven, EJ
机构
[1] Univ Hosp Dijkzigt, Dept Radiol, NL-3015 GD Rotterdam, Netherlands
[2] Univ Hosp Dijkzigt, Dept Cardiol, NL-3015 GD Rotterdam, Netherlands
[3] Leiden Univ Hosp, Lab Clin Expt Imaging, Leiden, Netherlands
[4] Interuniv Cardiol Inst Netherlands, Rotterdam, Netherlands
关键词
intravascular ultrasound; contour detection; peripheral arteries; atherosclerosis;
D O I
10.1016/S0301-5629(97)00238-X
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
An automated contour analysis system was previously developed to increase reproducibility and facilitate quantitative analyses of intravascular ultrasound (IVUS) images, The aim of this study was to compare measurements by this automated system with those obtained by conventional manual tracing, and to determine the intra-and interobserver variability of the automated system, IVUS images obtained in the femoropopliteal artery (n = 12) were analyzed with both systems, Area measurements by the automated system agreed well with the results obtained by manual tracing, displaying low coefficients of variation (8.5 to 15.7%) and high correlation coefficients (r = 0.92 to 0.98), Intra-and interobserver comparison of lumen area, vessel area, plaque area and percentage area stenosis showed low coefficients of variation (6.0 to 15.3% and 5.7 to 14.0%, respectively) and high correlation coefficients (both: r = 0.93 to 0.99), These data indicate that the automated analysis system is a reliable tool for the quantitative assessment of vessel dimensions in IVUS images obtained during clinical examination of peripheral arteries. (C) 1998 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:43 / 50
页数:8
相关论文
共 16 条
[1]   INTRAVASCULAR ULTRASOUND PREDICTORS OF OUTCOME AFTER PERIPHERAL BALLOON ANGIOPLASTY [J].
GUSSENHOVEN, EJ ;
VANDERLUGT, A ;
PASTERKAMP, G ;
VANDENBERG, FG ;
SIE, LH ;
VISCHJAGER, M ;
THE, SHK ;
LI, WG ;
PIETERMAN, H ;
VANURK, H .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1995, 10 (03) :279-288
[2]   ARTERIAL-WALL CHARACTERISTICS DETERMINED BY INTRAVASCULAR ULTRASOUND IMAGING - AN INVITRO STUDY [J].
GUSSENHOVEN, EJ ;
ESSED, CE ;
LANCEE, CT ;
MASTIK, F ;
FRIETMAN, P ;
VANEGMOND, FC ;
REIBER, J ;
BOSCH, H ;
VANURK, H ;
ROELANDT, J ;
BOM, N .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (04) :947-952
[3]  
GUSSENHOVEN EJ, 1993, DEV CARDIOVASC MED, V143, P157
[4]   CAN INTRACORONARY ULTRASOUND CORRECTLY ASSESS THE LUMINAL DIMENSIONS OF CORONARY-ARTERY LESIONS - A COMPARISON WITH QUANTITATIVE ANGIOGRAPHY [J].
HAASE, J ;
OZAKI, Y ;
DIMARIO, C ;
ESCANED, J ;
DEFEYTER, PJ ;
ROELANDT, JRTC ;
SERRUYS, PW .
EUROPEAN HEART JOURNAL, 1995, 16 (01) :112-119
[5]  
LI W, 1991, INT J CARDIAC IMAG, V6, P247
[6]   STUDY ON THE NUCLEAR-REACTIONS OF NB-93, TA-181, AND AU-197 INDUCED BY SECONDARY NEUTRONS IN 40 MEV/NUCLEON AR-40 ION COLLISIONS [J].
LI, WX ;
OHKUBO, Y ;
AMBE, S ;
KOBAYASHI, Y ;
IWAMOTO, M ;
MAEDA, H ;
AMBE, F .
CHEMISTRY LETTERS, 1994, (02) :277-280
[7]  
PETERS RJG, 1994, THESIS U AMSTERDAM, P55
[8]   CORONARY-ARTERY IMAGING WITH INTRAVASCULAR HIGH-FREQUENCY ULTRASOUND [J].
POTKIN, BN ;
BARTORELLI, AL ;
GESSERT, JM ;
NEVILLE, RF ;
ALMAGOR, Y ;
ROBERTS, WC ;
LEON, MB .
CIRCULATION, 1990, 81 (05) :1575-1585
[9]   Segmentation of intravascular ultrasound images: A knowledge-based approach [J].
Sonka, M ;
Zhang, XM ;
Siebes, M ;
Bissing, MS ;
DeJong, SC ;
Collins, SM ;
McKay, CR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1995, 14 (04) :719-732
[10]   Improved procedural results of coronary angioplasty with intravascular ultrasound-guided balloon sizing - The CLOUT pilot trial [J].
Stone, GW ;
Hodgson, JM ;
StGoar, FG ;
Frey, A ;
Mudra, H ;
Sheehan, H ;
Linnemeier, TJ .
CIRCULATION, 1997, 95 (08) :2044-2052