Flexible biosensors on spirally rolled micro tube for cardiovascular in vivo monitoring

被引:67
作者
Li, Chunyan [1 ]
Han, Jungyoup [1 ]
Ahn, Chong H. [1 ]
机构
[1] Univ Cincinnati, Dept Elect & Comp Engn & Comp Sci, Microsyst & BioMEMS Lab, Cincinnati, OH 45221 USA
关键词
spirally rolled polymer tube; glucose sensor; flexible substrate; microcatheter;
D O I
10.1016/j.bios.2006.08.043
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
New flexible biosensors on a spirally rolled micro tube have been designed, fabricated and characterized for microcatheter-based cardiovascular in vivo monitoring. With this new microfabrication method, sensors, wires and circuits can be fabricated first on the flexible polymer substrate (Kapton film) and then rolled spirally to make micro tubes with different diameters. This approach provides a unique method for mounting multiple sensors on both the inside and outside the tube. So, the new spirally rolled polymer tube flexibly conceives physical, biomedical and physiological microsensors, elevating most problems arisen from wiring and assembling of microsensors in conventional microcatheters. As a demonstration vehicle, we fabricated glucose biosensors on the 25 mu m thick Kapton film first, then the film was spirally rolled to make a polymer micro tube with the glucose sensors on the inside wall of the tube. To verify the performance of the spirally rolled glucose biosensor, we characterized it both in a planar unrolled and rolled conditions and compared their performances. The spirally rolled glucose sensors showed good performance in the typical glucose concentration range in human blood from 60 mg/dL to 120 mg/dL with different rolled diameters at different working temperature. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1988 / 1993
页数:6
相关论文
共 25 条
[1]   Disposable Smart lab on a chip for point-of-care clinical diagnostics [J].
Ahn, CH ;
Choi, JW ;
Beaucage, G ;
Nevin, JH ;
Lee, JB ;
Puntambekar, A ;
Lee, JY .
PROCEEDINGS OF THE IEEE, 2004, 92 (01) :154-173
[2]   MECHANICAL-PROPERTIES AND BIOCOMPATIBILITY OF 2 POLYEPOXY MATRICES - DGEBA-DDM AND DGEBA-IPD [J].
BERRUET, R ;
VINARD, E ;
CALLE, A ;
TIGHZERT, HL ;
CHABERT, B ;
MAGLOIRE, H ;
ELOY, R .
BIOMATERIALS, 1987, 8 (03) :162-171
[3]  
French P., 2003, SENSORS UPDATE, V13, P107, DOI DOI 10.1002/SEUP.200390018
[4]   A fully integrated biosensor array for measurement of metabolic parameters in human blood [J].
Gao, C ;
Choi, JW ;
Dutta, M ;
Chilukuru, S ;
Nevin, JH ;
Lee, JY ;
Bissell, MG ;
Ahn, CH .
2ND ANNUAL INTERNATIONAL IEEE-EMBS SPECIAL TOPIC CONFERENCE ON MICROTECHNOLOGIES IN MEDICINE & BIOLOGY, PROCEEDINGS, 2002, :223-226
[5]   Enhanced biocompatibility for SAOS-2 0steosarcoma cells by surface coating with hydrophobic epoxy resins [J].
Geckeler, KE ;
Wacker, R ;
Martini, R ;
Franz, M ;
Hack, A ;
Aicher, WK .
CELLULAR PHYSIOLOGY AND BIOCHEMISTRY, 2003, 13 (03) :155-164
[6]   Design considerations for silicon sensors for use in catheters and guide wires [J].
Goosen, JFL .
SMART MATERIALS & STRUCTURES, 2002, 11 (05) :804-812
[7]   CHEMICAL MICROSENSOR SYSTEMS FOR MEDICAL APPLICATIONS IN CATHETERS [J].
HINTSCHE, R ;
KRUSE, C ;
UHLIG, A ;
PAESCHKE, M ;
LISEC, T ;
SCHNAKENBERG, U ;
WAGNER, B .
SENSORS AND ACTUATORS B-CHEMICAL, 1995, 27 (1-3) :471-473
[8]   Novel hexacyanoferrate (III)-modified carbon electrodes: Application in miniaturized biosensors with potential for in vivo glucose sensing [J].
Jaffari, SA ;
Pickup, JC .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (11) :1167-1175
[9]  
JASON C, 2004, J BIOMED MATER RES, V70, P73
[10]  
KOSUKE T, 2003, BIOSENS BIOELECTRON, V18, P1439