High-resolution wide-field imaging of retinal and choroidal blood perfusion with optical microangiography

被引:81
作者
An, Lin [1 ]
Subhush, Hrebesh M. [1 ]
Wilson, David J. [2 ]
Wang, Ruikang K. [1 ]
机构
[1] Oregon Hlth & Sci Univ, Dept Biomed Engn, Portland, OR 97237 USA
[2] Oregon Hlth & Sci Univ, Sch Med, Casey Eye Inst, Portland, OR 97237 USA
基金
美国国家卫生研究院;
关键词
microcirculation; retinal imaging; choroidal imaging; optical coherence tomography; optical angiography; COHERENCE TOMOGRAPHY; IN-VIVO; MICRO-ANGIOGRAPHY; DOPPLER TOMOGRAPHY; VASCULAR PERFUSION; FLOW; FREQUENCY; ACQUISITION; DEEP;
D O I
10.1117/1.3369811
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present high-resolution wide-field imaging of retinal and choroidal blood perfusion with optical microangiography (OMAG) technology. Based on spatial frequency analysis, OMAG is capable of visualizing the vascular perfusion map down to capillary-level resolution. An OMAG system operating at 840 nm is used with an A-scan rate of 27,000 Hz, axial resolution of 8 mu m, and sensitivity of 98 dB. To achieve wide-field imaging, we capture 16 optical coherence tomography (OCT) 3-D datasets in,a sequential order, which together provide an area of similar to 7.4 x 7.4 mm(2) at the posterior segment of the human eye. For each of these datasets, the bulk tissue motion artifacts are eliminated by applying a phase compensation method based on histogram estimation of bulk motion phases, while the displacements occurring between adjacent B-frames are compensated for by 2-D cross correlation between two adjacent OMAG flow images. The depth-resolved capability of OMAG imaging also provides volumetric information on the ocular circulations. Finally, we compare the clinical fluorescein angiography and indocyanine green angiography imaging results with the OMAG results of blood perfusion map within the retina and choroid, and show excellent agreement between these modalities. (C) 2010 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3369811]
引用
收藏
页数:9
相关论文
共 27 条
[1]   In vivo volumetric imaging of vascular perfusion within human retina and choroids with optical micro-angiography [J].
An, Lin ;
Wang, Ruikang K. .
OPTICS EXPRESS, 2008, 16 (15) :11438-11452
[2]   Use of a scanner to modulate spatial interferograms for in vivo full-range Fourier-domain optical coherence tomography [J].
An, Lin ;
Wang, Ruikang K. .
OPTICS LETTERS, 2007, 32 (23) :3423-3425
[3]   Noninvasive imaging of in vivo blood flow velocity using optical Doppler tomography [J].
Chen, ZP ;
Milner, TE ;
Srinivas, S ;
Wang, XJ ;
Malekafzali, A ;
vanGemert, MJC ;
Nelson, JS .
OPTICS LETTERS, 1997, 22 (14) :1119-1121
[4]  
Fercher AF, 2003, REP PROG PHYS, V66, P239, DOI 10.2184/lsj.31.635
[5]   ON THE HISTOGRAM AS A DENSITY ESTIMATOR - L2 THEORY [J].
FREEDMAN, D ;
DIACONIS, P .
ZEITSCHRIFT FUR WAHRSCHEINLICHKEITSTHEORIE UND VERWANDTE GEBIETE, 1981, 57 (04) :453-476
[6]  
HOPEROSS M, 1994, OPHTHALMOLOGY, V101, P529
[7]   Simultaneous acquisition of sectional and fundus ophthalmic images with spectral-domain optical coherence tomography [J].
Jiao, SL ;
Knighton, R ;
Huang, XR ;
Gregori, G ;
Puliafito, CA .
OPTICS EXPRESS, 2005, 13 (02) :444-452
[8]  
KWITEROVICH KA, 1991, OPHTHALMOLOGY, V98, P1139
[9]   Real-time measurement of in vitro flow by Fourier-domain color Doppler optical coherence tomography [J].
Leitgeb, RA ;
Schmetterer, L ;
Hitzenberger, CK ;
Fercher, AF ;
Berisha, F ;
Wojtkowski, M ;
Bajraszewski, T .
OPTICS LETTERS, 2004, 29 (02) :171-173
[10]   Real-time assessment of retinal blood flow with ultrafast acquisition by color Doppler Fourier domain optical coherence tomography [J].
Leitgeb, RA ;
Schmetterer, L ;
Drexler, W ;
Fercher, AF ;
Zawadzki, RJ ;
Bajraszewski, T .
OPTICS EXPRESS, 2003, 11 (23) :3116-3121