Two novel real-time reverse transcriptase PCR assays for rapid detection of bacterial contamination in platelet concentrates

被引:42
作者
Dreier, J [1 ]
Störmer, M [1 ]
Kleesiek, K [1 ]
机构
[1] Ruhr Univ Bochum Klin, Herz & Diabet Zentrum Nordrhein Westfalen, Inst Lab & Transfus Med, D-32545 Bad Oeynhausen, Germany
关键词
D O I
10.1128/JCM.42.10.4759-4764.2004
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The incidence of platelet bacterial contamination is approximately 1 per 2,000 units and has been acknowledged as the most frequent infectious risk from transfusion. In preliminary studies, the sterility of platelet concentrates (PCs) was tested with an automated bacterial blood culturing system and molecular genetic assays. Two real-time reverse transcriptase PCR (RT-PCR) assays performed in a LightCycler instrument were developed and compared regarding specificity and sensitivity by the use of different templates to detect the majority of the clinically important bacterial species in platelets. Primers and probes specific for the conserved regions of the eubacterial 23S rRNA gene or the groEL gene (encoding the 60-kDa heat shock protein Hsp60) were designed. During the development of the 23S rRNA RT-PCR, problems caused by the contamination of reagents with bacterial DNA were noted. Treatment with 8-methoxypsoralen and UV irradiation reduced the level of contaminating DNA. The sensitivity of the assays was greatly influenced by the enzyme system which was used. With rTth DNA polymerase in a one-enzyme system, we detected 500 CFU of Escherichia coli or Staphylococcus epidermidis/ml. With a two-enzyme system consisting of Moloney murine leukemia virus RT and Taq DNA polymerase, we detected 16 CFU/ml. With groEL mRNA as the target of RT-PCR under optimized conditions, we detected 125 CFU of E. coli/ml, and no problems with false-positive results caused by reagent contamination or a cross-reaction with human nucleic acids were found. Furthermore, the use of mRNA as an indicator of viability was demonstrated. Here we report the application of novel real-time RT-PCR assays for the detection of bacterial contamination of PCs that are appropriate for transfusion services.
引用
收藏
页码:4759 / 4764
页数:6
相关论文
共 39 条
[1]   Experience with universal bacterial culturing to detect contamination of apheresis platelet units in a hospital transfusion service [J].
AuBuchon, JP ;
Cooper, LK ;
Leach, MF ;
Zuaro, DE ;
Schwartzman, JD .
TRANSFUSION, 2002, 42 (07) :855-861
[2]   Detection of viable Vibrio cholerae by reverse-transcriptase polymerase chain reaction (RT-PCR) [J].
Bej, AK ;
Ng, WY ;
Morgan, S ;
Jones, DD ;
Mahbubani, MH .
MOLECULAR BIOTECHNOLOGY, 1996, 5 (01) :1-10
[3]  
BOTTGER EC, 1990, CLIN CHEM, V36, P1258
[4]  
Brecher M E, 2002, Dev Biol (Basel), V108, P69
[5]   Evaluation of an automated culture system for detecting bacterial contamination of platelets: an analysis with 15 contaminating organisms [J].
Brecher, ME ;
Means, N ;
Jere, CS ;
Heath, D ;
Rothenberg, S ;
Stutzman, LC .
TRANSFUSION, 2001, 41 (04) :477-482
[6]   Detection of and discrimination between gram-positive and gram-negative bacteria in intraocular samples by using nested PCR [J].
Carroll, NM ;
Jaeger, EEM ;
Choudhury, S ;
Dunlop, AAS ;
Matheson, MM ;
Adamson, P ;
Okhravi, N ;
Lightman, S .
JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (05) :1753-1757
[7]  
Chaney R, 1999, TRANSFUSION MED, V9, P177
[8]   Contamination and sensitivity issues with a real-time universal 16S rRNA PCR [J].
Corless, CE ;
Guiver, M ;
Borrow, R ;
Edwards-Jones, V ;
Kaczmarski, EB ;
Fox, AJ .
JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (05) :1747-1752
[9]   Bacterial contamination of blood products: Factors, options, and insights [J].
Depcik-Smith, ND ;
Hay, SN ;
Brecher, ME .
JOURNAL OF CLINICAL APHERESIS, 2001, 16 (04) :192-201
[10]   Seven-day storage of apheresis platelets: report of an in vitro study [J].
Dumont, LJ ;
VandenBroeke, T .
TRANSFUSION, 2003, 43 (02) :143-150