A competitive enzyme-linked immunoassay using erythrocytes fixed to microtitre plates for anti-D quantitation in immunoglobulin products

被引:11
作者
Thorpe, SJ
Turner, CE
Heath, AC
Sands, D
机构
[1] Natl Inst Biol Stand & Controls, Div Haematol, Potters Bar EN6 3QG, Herts, England
[2] Natl Inst Biol Stand & Controls, Dept Informat, Potters Bar EN6 3QG, Herts, England
关键词
D O I
10.1159/000031220
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Objectives: The batch control of anti-D immunoglobulin for prevention of haemolytic disease of the newborn necessitates assessment of its potency. Anti-D quantitation is usually performed using automated haemagglutination methodology although this can only be carried out in specialist centres, The aim of this study was to develop a simple and robust assay for anti-D quantitation, Methods: We developed a competitive enzyme-linked immunoassay (EIA) in which unlabelled anti-D immunoglobulin and a biotinylated monoclonal anti-D compete for red cell binding. Binding of biotinylated anti-D is detected using an alkaline-phosphatase-labelled avidin preparation. The assay is conveniently carried out using erythrocytes fixed to microtitre plates. Results: The competitive EIA was specific for anti-D activity, highly reproducible and showed good correlation with manufacturers' potency estimates using automated haemagglutination, The assay was quick and simple to perform using freshly prepared or stored plates, and the biotinylated monoclonal anti-D could be lyophilized in ampoules for distribution as a standardized reagent. Conclusions: The competitive EIA described can be used for the specific quantitation of anti-D and provides a robust alternative method to automated haemagglutination, Copyright (C) 2000 S. Karger AG, Basel.
引用
收藏
页码:100 / 107
页数:8
相关论文
共 21 条
[1]   Evaluation by enzyme-linked immunosorbent assay of IgG anti-D and IgG subclass concentrations in immunoglobulin preparations [J].
Ahaded, A ;
Debbia, M ;
Beolet, M ;
Le Pennec, PY ;
Lambin, P .
TRANSFUSION, 1999, 39 (05) :515-521
[2]   Evaluation of a panel of human monoclonal antibodies to D and exploration of the synergistic effects of blending IgG1 and IgG3 antibodies on their in vitro biologic function [J].
Armstrong-Fisher, SS ;
Carter, MCM ;
Downing, I ;
Fraser, RH ;
Inglis, GE ;
Allan, EK ;
Mackie, A ;
Prowse, CV ;
Templeton, JG ;
Thorpe, SJ ;
Urbaniak, SJ .
TRANSFUSION, 1999, 39 (09) :1005-1012
[3]   ANTI-D QUANTIFICATION BY FLOW-CYTOMETRY - AN ALTERNATIVE TO THE AUTOANALYZER [J].
AUSTIN, EB ;
MCINTOSH, Y ;
HODSON, C ;
LEE, D .
TRANSFUSION MEDICINE, 1995, 5 (03) :203-208
[4]  
BOULT CE, 1997, TRANSFUS MED S1, V7, P26
[5]  
Finney DJ, 1978, STAT METHODS BIOL AS
[6]  
GOODRICK J, 1994, CLIN EXP IMMUNOL, V98, P17
[7]   MANIPULATIVE AND INHERENT ERRORS IN ANTI-D QUANTITATION USING AUTO ANALYZER [J].
GUNSON, HH ;
STRATTON, F ;
PHILLIPS, PK .
JOURNAL OF CLINICAL PATHOLOGY, 1972, 25 (03) :198-&
[8]  
Heusser C H, 1981, Methods Enzymol, V73, P406
[9]   Flow-cytometric quantitation of anti-D antibodies [J].
Hilden, JO ;
Backteman, K ;
Nilsson, J ;
Ernerudh, J .
VOX SANGUINIS, 1997, 72 (03) :172-176
[10]   AN ENZYME-LINKED-IMMUNOSORBENT-ASSAY FOR THE QUANTITATIVE-DETERMINATION OF ANTI-D IN PLASMA SAMPLES AND IMMUNOGLOBULIN PREPARATIONS [J].
HIRVONEN, M ;
TERVONEN, S ;
PIRKOLA, A ;
SIEVERS, G .
VOX SANGUINIS, 1995, 69 (04) :341-346