Improvements in absorbed dose measurements for external radiation therapy using ferrous dosimeter gel and MR imaging (FeMRI)

被引:17
作者
Back, SAJ [1 ]
Magnusson, P
Fransson, A
Olsson, LE
Montelius, A
Holmberg, O
Andreo, P
Mattsson, S
机构
[1] Lund Univ, Malmo Univ Hosp, Dept Radiat Phys, SE-20502 Malmo, Sweden
[2] Univ Vienna, Dept Biomed Engn & Phys, A-1090 Vienna, Austria
[3] Univ Uppsala Hosp, Dept Hosp Phys, SE-75185 Uppsala, Sweden
[4] St Lukes Hosp, Dept Phys, Dublin 6, Ireland
[5] IAEA, Dosimetry Sect RIHU, A-1400 Vienna, Austria
关键词
D O I
10.1088/0031-9155/43/2/004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A ferrous gel, based on ferrous (Fe) sulphate and agarose, was used with a clinical magnetic resonance imaging (MRI) scanner to obtain relative dose distribution data from therapeutic photon and electron beams. The FeMRI gel was scanned using a new MRI acquisition protocol optimized for T1 measurements. Thorough comparisons with silicon semiconductor detector and ionization chamber measurements, as well as with Monte Carlo calculations, were performed in order to quantify the improvements obtained using FeMRI for dose estimations. Most of the relative doses measured with FeMRI were within 2% of the doses measured with other methods. The larger discrepancies (2-4%) found at shallow depths are discussed. The uncertainty in relative dose measurements using FeMRI was significantly improved compared with previously reported results (5-10%, one standard deviation, 1 SD), and is today between 1.6% and 3.3% (depending on dose level, 2 SD). This corresponds to an improvement in the minimum detectable dose (3 SD above background) from approximately 2 Gy to better than 0.6 Gy. The results obtained in this study emphasize the importance of obtaining basic FeMRI dose data before the method is extended to complicated treatment regimes.
引用
收藏
页码:261 / 276
页数:16
相关论文
共 41 条
[1]   PRECISION, ACCURACY, AND IMAGE PLANE UNIFORMITY IN NMR RELAXATION-TIME IMAGING ON A 1.5-T WHOLE-BODY MR-IMAGING SYSTEM [J].
ANDERSEN, C ;
JENSEN, FT .
MAGNETIC RESONANCE IMAGING, 1994, 12 (05) :775-784
[2]   STOPPING-POWER RATIOS AND THEIR UNCERTAINTIES FOR CLINICAL ELECTRON-BEAM DOSIMETRY [J].
ANDREO, P ;
FRANSSON, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (12) :1847-1861
[3]  
Andreo P., 1987, ABSORBED DOSE DETERM
[4]  
[Anonymous], 1993, 50 ICRU
[5]  
[Anonymous], 1995, GUID EXPR UNC MEAS
[6]  
[Anonymous], 1984, 35 ICRU
[7]   Multiple-site fast exchange model for spin-lattice relaxation in the Fricke-gelatin dosimeter [J].
Audet, C ;
Schreiner, LJ .
MEDICAL PHYSICS, 1997, 24 (02) :201-209
[8]   DIFFUSION IN FE(II/III) RADIATION-DOSIMETRY GELS MEASURED BY MAGNETIC-RESONANCE-IMAGING [J].
BALCOM, BJ ;
LEES, TJ ;
SHARP, AR ;
KULKARNI, NS ;
WAGNER, GS .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (10) :1665-1676
[9]  
Bucciolini M., 1991, Physica Medica, V7, P125
[10]   CONFIRMATION OF TARGET LOCALIZATION AND DOSIMETRY FOR 3D CONFORMAL RADIOTHERAPY TREATMENT PLANNING BY MR-IMAGING OF A FERROUS SULFATE GEL HEAD PHANTOM [J].
CHAN, MF ;
AYYANGAR, KM .
MEDICAL PHYSICS, 1995, 22 (07) :1171-1175