Exploration of microwave plasma source cavity ring-down spectroscopy for elemental measurements

被引:17
作者
Duan, YX
Wang, CJ
Winstead, CB
机构
[1] Los Alamos Natl Lab, CACS, Los Alamos, NM 87545 USA
[2] Mississippi State Univ, Diagnost Instrumentat & Anal Lab, Starkville, MS 39759 USA
[3] Univ So Mississippi, Dept Phys & Astron, Hattiesburg, MS 39406 USA
关键词
D O I
10.1021/ac0207832
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We are exploring sensitive techniques for elemental measurements using cavity ring-down spectroscopy (CRDS) combined with a compact microwave plasma source as an atomic absorption cell. The research work marries the high sensitivity of CRDS with a low-power microwave plasma source to develop a new instrument that yields high sensitivity and capability for elemental measurements. CRDS can provide orders of magnitude improvement in sensitivity over conventional absorption techniques. Additional benefit is gained from a compact microwave plasma source that possesses the advantages of low power and low-plasma gas flow rate, which are of benefit for atomic absorption measurements. A laboratory CRDS system consisting of a tunable dye laser is used in this work for developing a scientific base and demonstrating the feasibility of the technique. A laboratory-designed and -built sampling system for solution sample introduction is used for testing. The ring-down signals are monitored using a photomultiplier tube and recorded using a digital oscilloscope interfaced to a computer. Lead is chosen as a typical element for the system optimization and characterization. The effects of baseline noise from the plasma source are reported. A detection limit of 0.8 ppb (10(-10)) is obtained with such a device.
引用
收藏
页码:2105 / 2111
页数:7
相关论文
共 33 条
[1]  
[Anonymous], SPECTROCHEMICAL ANAL
[2]   THE WIDTHS AND SHAPES OF ABOUT 350 PROMINENT LINES OF 65 ELEMENTS EMITTED BY AN INDUCTIVELY COUPLED PLASMA [J].
BOUMANS, PWJM ;
VRAKKING, JJAM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1986, 41 (12) :1235-1275
[3]  
Breene RG, 1961, The shift and shape of spectral lines
[4]  
BUSCH KW, 1999, ACS S SERIES, V720
[5]   Design and development of a highly sensitive, field portable plasma source instrument for on-line liquid stream monitoring and real-time sample analysis [J].
Duan, YX ;
Su, YX ;
Jin, Z ;
Abeln, SP .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (03) :1557-1563
[6]   STUDY ON MICROWAVE-INDUCED PLASMA-ATOMIC ABSORPTION SPECTROMETRY (MIP-AAS) FOR THE DETERMINATION OF CALCIUM IN AXIAL VIEWING MODE [J].
DUAN, YX ;
HUO, MY ;
LIU, J ;
JIN, QH .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 349 (04) :277-282
[7]   EVALUATION OF THE PERFORMANCE OF MICROWAVE-INDUCED PLASMA-ATOMIC ABSORPTION SPECTROMETRY (MIP-AAS) [J].
DUAN, YX ;
HOU, MY ;
DU, ZH ;
JIN, QH .
APPLIED SPECTROSCOPY, 1993, 47 (11) :1871-1879
[8]   ELECTROTHERMAL VAPORIZATION FOR SAMPLE INTRODUCTION IN MICROWAVE-INDUCED PLASMA-ATOMIC ABSORPTION SPECTROMETRY [J].
DUAN, YX ;
LI, XY ;
JIN, QH .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (08) :1091-1096
[9]   A field portable plasma source monitor for real-time air particulate monitoring [J].
Duan, YX ;
Su, YX ;
Jin, Z ;
Abeln, SP .
ANALYTICAL CHEMISTRY, 2000, 72 (07) :1672-1679
[10]   DESOLVATION EFFECT ON THE ANALYTICAL PERFORMANCE OF MICROWAVE-INDUCED PLASMA-ATOMIC ABSORPTION SPECTROMETRY (MIP-AAS) [J].
DUAN, YX ;
ZHANG, HQ ;
HUO, MY ;
JIN, QH .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1994, 49 (06) :583-592