Effect of acidity on the enantiomeric resolution of thyroxine and tocainide by HPLC on a (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid column

被引:17
作者
Aboul-Enein, HY
Ali, I
Hyun, MH
Cho, YJ
Jin, JS
机构
[1] King Faisal Specialist Hosp & Res Ctr, Biol & Med Res Dept MBC 03, Riyadh 11211, Saudi Arabia
[2] Pusan Natl Univ, Dept Chem, Pusan 609735, South Korea
[3] Pusan Natl Univ, Chem Inst Funct Mat, Pusan 609735, South Korea
[4] Korea Food & Drug Adm, Dept Drug Evaluat, Enpyung Ku, Seoul 122704, South Korea
来源
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS | 2002年 / 54卷 / 1-3期
关键词
chiral resolution; thyroxine; tocamide; (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid column; chiral crown ether;
D O I
10.1016/S0165-022X(02)00142-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Enantiomeric resolution of thyroxine and tocainide was achieved on a (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid column. The mobile phases were methanol/water (4:1, v/v) and methanol/water containing 5 mM sulfuric acid (4:1, v/v) for tocainide and thyroxine respectively. The flow rate was 0.5 ml/min. The effect of the acidity on the chiral resolution of these drugs was studied. Detection was at 220 nm for both drugs. The values of alpha and Rs were 2.08-3.11 and 1.00-2.60, respectively, for thyroxine while the values of alpha and Rs were 1.13-1.26 and 0.10-1.30, respectively, for tocainide. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:407 / 413
页数:7
相关论文
共 13 条
[1]   Macrocyclic antibiotics as effective chiral selectors for enantiomeric resolution by liquid chromatography and capillary electrophoresis [J].
Aboul-Enein, HY ;
Ali, I .
CHROMATOGRAPHIA, 2000, 52 (11-12) :679-691
[2]  
ABOULENEIN HY, 1997, IMPACT STEREOCHEMIST, V142
[3]  
ALLENMARK S, 1991, CHROMATOGRAPHIE ENAN
[4]  
BEESLEY TE, 1998, CHIRAL CHROMATOGRAPH
[5]  
FDA, 1992, POL STAT DEV NEW STE
[6]   Liquid chromatographic resolution of racemic compounds containing a primary amino group on a dynamic chiral stationary phase derived from chiral crown ether [J].
Hyun, MH ;
Koo, HJ ;
Jin, JS ;
Lee, W .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2000, 23 (17) :2669-2682
[7]   Liquid chromatographic resolution of racemic amino acids and their derivatives on a new chiral stationary phase based on crown ether [J].
Hyun, MH ;
Jin, JS ;
Lee, WJ .
JOURNAL OF CHROMATOGRAPHY A, 1998, 822 (01) :155-161
[8]  
Hyun MH, 1998, B KOREAN CHEM SOC, V19, P819
[9]   Liquid chromatographic resolution of racemic amines and amino alcohols on a chiral stationary phase derived from crown ether [J].
Hyun, MH ;
Jin, JS ;
Koo, HJ ;
Lee, WJ .
JOURNAL OF CHROMATOGRAPHY A, 1999, 837 (1-2) :75-82
[10]   Separation of the stereoisomers of racemic fluoroquinolone antibacterial agents on a crown-ether-based chiral HPLC stationary phase [J].
Hyun, MH ;
Han, SC ;
Jin, JS ;
Lee, W .
CHROMATOGRAPHIA, 2000, 52 (7-8) :473-476