Monte Carlo simulation of x-ray spectra in diagnostic radiology and mammography using MCNP4C

被引:121
作者
Ay, MR [1 ]
Shahriari, M
Sarkar, S
Adib, M
Zaidi, H
机构
[1] AmirkKabir Univ Technol, Dept Phys & Ncl Sci, Tehran, Iran
[2] Univ Hosp Geneva, Div Nucl Med, CH-1211 Geneva, Switzerland
[3] Shahid Beheshti Univ, Dept Nucl Engn, Tehran, Iran
[4] Univ Tehran, Dept Med Phys, Tehran, Iran
[5] IPP Co, GE Med Syst, Iran Authorized Distributor, Tehran, Iran
关键词
D O I
10.1088/0031-9155/49/21/004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The general purpose Monte Carlo N-particle radiation transport computer code (MCNP4C) was used for the simulation of x-ray spectra in diagnostic radiology and mammography. The electrons were transported until they slow down and stop in the target. Both bremsstrahlung and characteristic x-ray production were considered in this work. We focus on the simulation of various target/filter combinations to investigate the effect of tube voltage, target material and filter thickness on x-ray spectra in the diagnostic radiology and mammography energy ranges. The simulated x-ray spectra were compared with experimental measurements and spectra calculated by IPEM report number 78. In addition, the anode heel effect and off-axis x-ray spectra were assessed for different anode angles and target materials and the results were compared with EGS4-based Monte Carlo simulations and measured data. Quantitative evaluation of the differences between our Monte Carlo simulated and comparison spectra was performed using student's t-test statistical analysis. Generally, there is a good agreement between the simulated x-ray and comparison spectra, although there are systematic differences between the simulated and reference spectra especially in the K-characteristic x-rays intensity. Nevertheless, no statistically significant differences have been observed between IPEM spectra and the simulated spectra. It has been shown that the difference between MCNP Simulated spectra and IPEM spectra in the low energy range is the result of the overestimation of characteristic photons following the normalization procedure. The transmission curves produced by MCNP4C have good agreement with the IPEM report especially for tube voltages of 50 kV and 80 kV The systematic discrepancy for higher tube voltages is the result of systematic differences between the corresponding spectra.
引用
收藏
页码:4897 / 4917
页数:21
相关论文
共 36 条
[1]   Monte Carlo simulation of x-ray emission by kilovolt electron bombardment [J].
Acosta, E ;
Llovet, X ;
Coleoni, E ;
Riveros, JA ;
Salvat, F .
JOURNAL OF APPLIED PHYSICS, 1998, 83 (11) :6038-6049
[2]   Empirical investigation of the signal performance of a high-resolution, indirect detection, active matrix flat-panel imager (AMFPI) for fluoroscopic and radiographic operation [J].
Antonuk, LE ;
ElMohri, Y ;
Siewerdsen, JH ;
Yorkston, J ;
Huang, W ;
Scarpine, VE ;
Street, RA .
MEDICAL PHYSICS, 1997, 24 (01) :51-70
[3]  
AY M, 2004, IN PRESS P IEEE NUCL
[4]   An investigation of entrance surface dose calculations for diagnostic radiology using Monte Carlo simulations and radiotherapy dosimetry formalisms [J].
Ben Omrane, L ;
Verhaegen, F ;
Chahed, N ;
Mtimet, S .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (12) :1809-1824
[5]  
BERGER MJ, 1987, 873597 NBSIR US NBS
[6]   Off-axis x-ray spectra: A comparison of Monte Carlo simulated and computed x-ray spectra with measured spectra [J].
Bhat, M ;
Pattison, J ;
Bibbo, G ;
Caon, M .
MEDICAL PHYSICS, 1999, 26 (02) :303-309
[7]   Diagnostic x-ray spectra: A comparison of spectra generated by different computational methods with a measured spectrum [J].
Bhat, M ;
Pattison, J ;
Bibbo, G ;
Caon, M .
MEDICAL PHYSICS, 1998, 25 (01) :114-120
[8]   COMPUTATION OF BREMSSTRAHLUNG X-RAY-SPECTRA AND COMPARISON WITH SPECTRA MEASURED WITH A GE(LI) DETECTOR [J].
BIRCH, R ;
MARSHALL, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (03) :505-517
[9]  
BIRCH R, 1979, ASS SCI REPORT SERIE, V30
[10]   Calculated mammographic spectra confirmed with attenuation curves for molybdenum, rhodium, and tungsten targets [J].
Blough, MM ;
Waggener, RG ;
Payne, WH ;
Terry, JA .
MEDICAL PHYSICS, 1998, 25 (09) :1605-1612