Partial-volume effect in PET tumor imaging

被引:1195
作者
Soret, Marine
Bacharach, Stephen L.
Buvat, Irene
机构
[1] CHU Pitie Salpetriere, INSERM, UMR 678, UPMC, F-75634 Paris 13, France
[2] HIA Val Grace, Dept Nucl Med, Paris, France
[3] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
关键词
PET; tumor imaging; partial volume; standardized uptake value;
D O I
10.2967/jnumed.106.035774
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PET has the invaluable advantage of being intrinsically quantitative, enabling accurate measurements of tracer concentrations in vivo. In PET tumor imaging, indices characterizing tumor uptake, such as standardized uptake values, are becoming increasingly important, especially in the context of monitoring the response to therapy. However, when tracer uptake in small tumors is measured, large biases can be introduced by the partial-volume effect (PVE). The purposes of this article are to explain what PVE is and to describe its consequences in PET tumor imaging. The parameters on which PVE depends are reviewed. Actions that can be taken to reduce the errors attributable to PVE are described. Various PVE correction schemes are presented, and their applicability to PETtumor imaging is discussed.
引用
收藏
页码:932 / 945
页数:14
相关论文
共 60 条
[1]   EVALUATION OF THE FACTORS AFFECTING THE ACCURACY AND PRECISION OF A TECHNIQUE FOR QUANTIFICATION OF VOLUME AND ACTIVITY IN SPECT [J].
ALAAMER, AS ;
FLEMING, JS ;
PERRING, S .
NUCLEAR MEDICINE COMMUNICATIONS, 1994, 15 (09) :758-771
[2]   Modeling and incorporation of system response functions in 3-D whole body PET [J].
Alessio, Adam M. ;
Kinahan, Paul E. ;
Lewellen, Thomas K. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (07) :828-837
[3]   Positron emission tomography partial volume correction: Estimation and algorithms [J].
Aston, JAD ;
Cunningham, VJ ;
Asselin, MC ;
Hammers, A ;
Evans, AC ;
Gunn, RN .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2002, 22 (08) :1019-1034
[4]  
Avril N, 1997, J NUCL MED, V38, P1186
[5]   Metabolic characterization of breast tumors with positron emission tomography using F-18 fluorodeoxyglucose [J].
Avril, N ;
Dose, J ;
Janicke, F ;
Bense, S ;
Ziegler, S ;
Laubenbacher, C ;
Romer, W ;
Pache, H ;
Herz, M ;
Allgayer, B ;
Nathrath, W ;
Graeff, H ;
Schwaiger, M .
JOURNAL OF CLINICAL ONCOLOGY, 1996, 14 (06) :1848-1857
[6]  
Avril N, 2001, J NUCL MED, V42, P9
[7]   Measuring tumor blood flow with H215O:: Practical considerations [J].
Bacharach, SL ;
Libutti, SK ;
Carrasquillo, JA .
NUCLEAR MEDICINE AND BIOLOGY, 2000, 27 (07) :671-676
[8]   Evaluation of anatomy based reconstruction for partial volume correction in brain FDG-PET [J].
Baete, K ;
Nuyts, J ;
Van Laere, K ;
Van Paesschen, W ;
Ceyssens, S ;
De Ceuninck, L ;
Gheysens, O ;
Kelles, A ;
Van den Eynden, J ;
Suetens, P ;
Dupont, P .
NEUROIMAGE, 2004, 23 (01) :305-317
[9]   NONINVASIVE QUANTITATION OF MYOCARDIAL BLOOD-FLOW IN HUMAN-SUBJECTS WITH OXYGEN-15-LABELED WATER AND POSITRON EMISSION TOMOGRAPHY [J].
BERGMANN, SR ;
HERRERO, P ;
MARKHAM, J ;
WEINHEIMER, CJ ;
WALSH, MN .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (03) :639-652
[10]  
Boellaard R, 2004, J NUCL MED, V45, P1519