摘要
A new indirect contact (IDC) electrocardiogram (ECG) measurement method (IDC-ECG) for monitoring ECG during sleep that is adequate for long-term use is provided. The provided method did not require any direct conductive contact between the instrument and bare skin. This method utilizes an array of high-input-impedance active electrodes fixed on the mattress and an indirect-skin-contact ground made of a large conductive textile sheet. A thin cotton bedcover covered the mattress, electrodes, and conductive textile, and the participants were positioned on the mattress over the bedcover. An ECG was successfully obtained, although the signal quality was lower and the motion artifact was larger than in conventional direct-contact measurements (DC-ECG). The results showed that further studies are required to apply the provided method to an ECG diagnosis of cardiovascular diseases. However, currently the method can be used for HRV assessment with easy discrimination of R-peaks.
引用
收藏
页码:718 / 725
页数:8
相关论文
共 20 条
[1]   STATIC CHARGE SENSITIVE BED - NEW METHOD FOR RECORDING BODY MOVEMENTS DURING SLEEP [J].
ALIHANKA, J ;
VAAHTORANTA, K .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1979, 46 (06) :731-734
[2]  
Baxter L. K., 1997, CAPACITIVE SENSORS D, P48
[3]  
Camm AJ, 1996, EUR HEART J, V17, P354
[4]   Air mattress sensor system with balancing tube for unconstrained measurement of respiration and heart beat movements [J].
Chee, Y ;
Han, J ;
Youn, J ;
Park, K .
PHYSIOLOGICAL MEASUREMENT, 2005, 26 (04) :413-422
[5]   Home diagnosis of sleep apnea: A systematic review of the literature - An evidence review cosponsored by the American academy of sleep medicine, the American College of Chest Physicians, and the American Thoracic Society [J].
Flemons, WW ;
Littner, MR ;
Rowley, JA ;
Gay, P ;
Anderson, WM ;
Hudgel, DW ;
McEvoy, RD ;
Loube, DI .
CHEST, 2003, 124 (04) :1543-1579
[6]   IMPROVED CAPACITIVE ELECTROCARDIOGRAM ELECTRODES FOR BURN APPLICATIONS [J].
GRIFFITH, ME ;
PORTNOY, WM ;
STOTTS, LJ ;
DAY, JL .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1979, 17 (05) :641-646
[7]   A compact electric potential sensor array for the acquisition and reconstruction of the 7-lead electrocardiogram without electrical charge contact with the skin [J].
Harland, CJ ;
Clark, TD ;
Peters, NS ;
Everitt, MJ ;
Stiffell, PB .
PHYSIOLOGICAL MEASUREMENT, 2005, 26 (06) :939-950
[8]   MONITORING OF ELECTROCARDIOGRAMS IN BED WITHOUT UTILIZING BODY-SURFACE ELECTRODES [J].
ISHIJIMA, M .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1993, 40 (06) :593-594
[9]  
Jonassen N., 2002, ELECTROSTATICS, P121
[10]  
JONASSEN N, 2002, ELECTROSTATICS, P31