ECC recording on a bed during steep without direct skin-contact

被引:170
作者
Lim, Yong Gyu
Kim, Ko Keun
Park, Kwang Suk [1 ]
机构
[1] Seoul Natl Univ, Dept Biomed Engn, Seoul 100799, South Korea
[2] Seoul Natl Univ, Interdisciplinary Program Med & Biol Engn, Seoul 100799, South Korea
[3] Sangji Univ, Dept Oriental Biomed Engn, Wonju 220702, South Korea
关键词
active electrode; ECG monitoring on a bed; high-input impedance; indirect-contact ECG;
D O I
10.1109/TBME.2006.889194
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new indirect contact (IDC) electrocardiogram (ECG) measurement method (IDC-ECG) for monitoring ECG during sleep that is adequate for long-term use is provided. The provided method did not require any direct conductive contact between the instrument and bare skin. This method utilizes an array of high-input-impedance active electrodes fixed on the mattress and an indirect-skin-contact ground made of a large conductive textile sheet. A thin cotton bedcover covered the mattress, electrodes, and conductive textile, and the participants were positioned on the mattress over the bedcover. An ECG was successfully obtained, although the signal quality was lower and the motion artifact was larger than in conventional direct-contact measurements (DC-ECG). The results showed that further studies are required to apply the provided method to an ECG diagnosis of cardiovascular diseases. However, currently the method can be used for HRV assessment with easy discrimination of R-peaks.
引用
收藏
页码:718 / 725
页数:8
相关论文
共 20 条
[11]  
Kawarada A, 2000, P ANN INT IEEE EMBS, V22, P531, DOI 10.1109/IEMBS.2000.900794
[12]   ECG measurement on a chair without conductive contact [J].
Lim, YG ;
Kim, KK ;
Park, KS .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (05) :956-959
[13]  
Malmivuo J., 1995, BIOELECTROMAGNETISM, P277, DOI DOI 10.1093/ACPROF:OSO/9780195058239.001.0001
[14]  
OLSON WH, 1992, MED INSTRUM, P751
[15]  
PORTNOY WM, 1974, BIOMEDICAL ELECTRODE, P7
[16]   A direct comparison of wet, dry and insulating bioelectric recording electrodes [J].
Searle, A ;
Kirkup, L .
PHYSIOLOGICAL MEASUREMENT, 2000, 21 (02) :271-283
[17]   Unconstrained and non-invasive measurement of heart-beat and respiration periods using a phonocardiographic sensor [J].
Tanaka, S ;
Matsumoto, Y ;
Wakimoto, K .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2002, 40 (02) :246-252
[18]   HIGH-QUALITY RECORDING OF BIOELECTRIC EVENTS .1. INTERFERENCE REDUCTION, THEORY AND PRACTICE [J].
VANRIJN, ACM ;
PEPER, A ;
GRIMBERGEN, CA .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (05) :389-397
[19]   Noninvasive measurement of heartbeat, respiration, snoring and body movements of a subject in bed via a pneumatic method [J].
Watanabe, K ;
Watanabe, T ;
Watanabe, H ;
Ando, H ;
Ishikawa, T ;
Kobayashi, K .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (12) :2100-2107
[20]   REDUCTION OF INTERFERENCE DUE TO COMMON-MODE VOLTAGE IN BIOPOTENTIAL AMPLIFIERS [J].
WINTER, BB ;
WEBSTER, JG .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1983, 30 (01) :58-62