Far-field R wave oversensing in dual chamber pacemakers designed for atrial arrhythmia management: Effect of pacing site and lead tip to ring distance

被引:17
作者
Inama, G
Santini, M
Padeletti, L
Boriani, G
Botto, G
Capucci, A
Gulizia, M
Ricci, R
Rizzon, P
Ferri, F
Miraglia, F
Raneri, R
Grammatico, A
机构
[1] Maggiore Hosp, Dept Cardiol, Inst Cardiol, I-26013 Crema, CR, Italy
[2] S Filippo Neri Hosp, Inst Cardiol, Rome, Italy
[3] Univ Florence, Inst Internal Med & Cardiol, Florence, Italy
[4] Univ Bologna, Inst Cardiol, S Orsola M Malpighi Hosp, Bologna, Italy
[5] St Anna Hosp, Inst Cardiol, Como, Italy
[6] Civile Hosp, Inst Cardiol, Piacenza, Italy
[7] S Luigi S Curro Hosp, Inst Cardiol, Catania, Italy
[8] Policlin Hosp, Inst Cardiol, Bari, Italy
[9] Fatebenefratelli Villa S Pietro Hosp, Inst Cardiol, Rome, Italy
[10] Medtron Italia, Rome, Italy
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2004年 / 27卷 / 09期
关键词
atrial tachyarrhythmia; pacing site; far-field oversensing; tip to ring distance;
D O I
10.1111/j.1540-8159.2004.00613.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of the study was to determine the incidence and practical implications of for-field R wave oversensing (FFRWO) and its association with pacing site and lead tip to ring spacing (TTRS) in implantable devices designed to diagnose and treat atrial tachyarrhythmias and programmed with a fixed and short postventricular blanking period. The study included 395 patients who were implanted with a DDDRP pacemaker and prospectively followed. At implant and follow-up visits FFRWO was assessed by analyzing lead electrical measures and atrial tachyarrhythmic episodes collected in the device diagnostics. During a median follow-up of 12 months 11 (2.8%) of 395 patients showed a clinically significant FFRWO that induced inappropriate detection or pacemaker malfunctioning. The atrial pacing site of these 11 patients was right atrium appendage (RAA) for 3 patients, representing 1.1% of 254 RAA patients, coronary sinus ostium (CSO) for 7 patients, representing 7.4% of 94 CSO patients (P < 0.005 vs RAA), and lateral wall (LW) for 1 (2.9%) of 34 LW patients. The minimal value of the FFRWO to P wave ratio, measured at implant, associated with a clinically significant FFRWO was 0.6; therefore, a value of 0.5 was used as a cutoff to identify patients at risk of undesirable device behavior induced by FFRWO: there were 11 (9.6%) of 114 of RAA patients with short (< 10 mm) TTRS, 22 (18.8%) of 117 of RAA patients with long (greater than or equal to 17 mm) TTRS (P < 0.05 vs short TTRS), 21 (30.6%) of 64 of CSO patients short TTRS (P < 0.001 vs RAA patients with short TTRS) and 3 (30%) of 10 of CSO patients with long TTRS. The analysis showed that, despite the short postventricular blanking time, FFRWO inducing undesired functioning in AT500 pacemakers is infrequent (2.8% of patients). Compared to RAA, the CSO lead position was more frequently associated with FFRWO.TTRS < 10 mm was associated with lower risk of clinically significant FFRWO in RAA.
引用
收藏
页码:1221 / 1230
页数:10
相关论文
共 18 条
[1]   Prevention of chronic atrial fibrillation by pacing in the region of Bachmann's bundle: Results of a multicenter randomized trial [J].
Bailin, SJ ;
Adler, S ;
Giudici, M .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2001, 12 (08) :912-917
[2]   Analysis of atrial sensed far-field ventricular signals: A reassessment [J].
Brouwer, J ;
Nagelkerke, D ;
denHeijer, P ;
Ruiter, JH ;
Mulder, H ;
Begemann, MJS ;
Lie, KI .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (04) :916-922
[3]   Current concepts - Implantable devices for the treatment of atrial fibrillation [J].
Cooper, JM ;
Katcher, MS ;
Orlov, MV .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (26) :2062-2068
[4]   A fractally coated, 1.3 mm2 high impedance pacing electrode [J].
Fröhlig, G ;
Bolz, A ;
Ströbel, J ;
Rutz, M ;
Lawall, P ;
Schwerdt, H ;
Schaldach, M ;
Schieffer, H .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (06) :1239-1246
[5]   Bipolar ventricular far-field signals in the atrium [J].
Fröhlig, G ;
Helwani, Z ;
Kusch, O ;
Berg, M ;
Schieffer, H .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (11) :1604-1613
[6]   Safety and efficacy of advanced atrial pacing therapies for atrial tachyarrhythmias in patients with a new implantable dual chamber cardioverter-defibrillator [J].
Gillis, AM ;
Unterberg-Buchwald, C ;
Schmidinger, H ;
Massimo, S ;
Wolfe, K ;
Kavaney, DJ ;
Otterness, MF ;
Hohnloser, SH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (09) :1653-1659
[7]  
Gillis Anne M., 2000, Cardiology Clinics, V18, P25, DOI 10.1016/S0733-8651(05)70125-9
[8]   ACC/AHA Guidelines for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices: Executive summary - A report of the American College of Cardiology American Heart Association Task Force on Practice Guidelines (Committee on Pacemaker Implantation) [J].
Gregoratos, G ;
Cheitlin, MD ;
Conill, A ;
Epstein, AE ;
Fellows, C ;
Ferguson, TB ;
Freedman, RA ;
Hlatky, MA ;
Naccarelli, GV ;
Saksena, S ;
Schlant, RC ;
Silka, MJ .
CIRCULATION, 1998, 97 (13) :1325-1335
[9]   Prevalence, characteristics and clinical implications of regular atrial tachyarrhythmias in patients with atrial fibrillation:: Insights from a study using a new implantable device [J].
Israel, CW ;
Ehrlich, JR ;
Grönefeld, G ;
Klesius, A ;
Lawo, T ;
Lemke, B ;
Hohnloser, SH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (02) :355-363
[10]   Pace-termination and pacing for prevention of atrial tachyarrhythmias:: Results from a multicenter study with an implantable device for atrial therapy [J].
Israel, CW ;
Hügl, B ;
Unterberg, C ;
Lawo, T ;
Kennis, I ;
Hettrick, D ;
Hohnloser, SH .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2001, 12 (10) :1121-1128