MR angiography of the supra-aortic arteries using a dedicated head and neck coil: image quality and assessment of stenoses

被引:12
作者
Fellner, C
Strotzer, M
Fraunhofer, S
Held, P
Spies, V
Seitz, J
Fellner, F
机构
[1] UNIV ERLANGEN NURNBERG,DEPT DIAGNOST RADIOL,D-91054 ERLANGEN,GERMANY
[2] UNIV REGENSBURG,DEPT RADIOL,D-93042 REGENSBURG,GERMANY
[3] UNIV REGENSBURG,DEPT SURG,D-93042 REGENSBURG,GERMANY
关键词
magnetic resonance angiography; arteries; supra-aortic; artery carotid; pulse sequences;
D O I
10.1007/s002340050502
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Our purpose was to evaluate a dedicated head and neck coil for demonstration of supra-aortic arteries with optimised magnetic resonance angiography techniques. We performed 47 examinations with a 1.5-T system. We used coronal 3D fast imaging with steady precession (FISP), axial 3D tilted optimised nonsaturating excitation (TONE) and 2D fast low-angle shot (FLASH) for the carotid bifurcation, axial 3D TONE with or without magnetisation transfer (MT) for intracranial arteries, and axial 3D FISP or TONE for the aortic arch. Evaluation included visual assessment of image quality and grading of stenoses near the carotid bifurcation; digital subtraction angiography was used as the reference method. Axial 3D TONE gave superior image quality at the carotid bifurcation, MT-TONE intracranially, and 3D FISP for the aortic arch vessels. Nevertheless, sensitivity and specificity for detection of significant stenoses were similar with coronal 3D FISP (96.3 %, 94.0 %), axial 3D TONE (92.6 %, 92.5 %) and axial 2D FLASH (96.3 %, 86.6 %), Image quality at the aortic arch needs further improvement.
引用
收藏
页码:763 / 771
页数:9
相关论文
共 27 条
[1]   DEDICATED COIL FOR CAROTID MR ANGIOGRAPHY [J].
ANDERSON, CM ;
SALONER, D ;
LEE, RE ;
FORTNER, A .
RADIOLOGY, 1990, 176 (03) :868-872
[2]  
ANDERSON CM, 1992, AM J NEURORADIOL, V13, P989
[3]   IMPROVED MR-ANGIOGRAPHY - MAGNETIZATION-TRANSFER SUPPRESSION WITH VARIABLE FLIP ANGLE EXCITATION AND INCREASED RESOLUTION [J].
ATKINSON, D ;
BRANTZAWADZKI, M ;
GILLAN, G ;
PURDY, D ;
LAUB, G .
RADIOLOGY, 1994, 190 (03) :890-894
[4]  
BLATTER DD, 1993, AM J ROENTGENOL, V161, P1269, DOI 10.2214/ajr.161.6.8249741
[5]  
CARRIERO A, 1995, J NEURORADIOLOGY, V22, P103
[6]   3-DIMENSIONAL TIME-OF-FLIGHT MAGNETIC-RESONANCE ANGIOGRAPHY IN CAROTID-ARTERY SURGERY - A COMPARISON WITH DIGITAL SUBTRACTION ANGIOGRAPHY [J].
CHIESA, R ;
MELISSANO, G ;
CASTELLANO, R ;
TRIULZI, F ;
ANZALONE, N ;
VEGLIA, F ;
SCOTTI, G ;
GROSSI, A .
EUROPEAN JOURNAL OF VASCULAR SURGERY, 1993, 7 (02) :171-176
[7]   HIGH-RESOLUTION, MAGNETIZATION-TRANSFER SATURATION, VARIABLE FLIP ANGLE, TIME-OF-FLIGHT MRA IN THE DETECTION OF INTRACRANIAL VASCULAR STENOSES [J].
DAGIRMANJIAN, A ;
ROSS, JS ;
OBUCHOWSKI, N ;
LEWIN, JS ;
TKACH, JA ;
RUGGIERI, PM ;
MASARYK, TJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1995, 19 (05) :700-706
[8]   PROSPECTIVE EVALUATION OF EXTRACRANIAL CAROTID STENOSIS - NIR ANGIOGRAPHY WITH MAXIMUM-INTENSITY PROJECTIONS AND MULTIPLANAR REFORMATION COMPARED WITH CONVENTIONAL ANGIOGRAPHY [J].
DEMARCO, JK ;
NESBIT, GM ;
WESBEY, GE ;
RICHARDSON, D .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (05) :1205-1212
[9]   IMPROVED TIME-OF-FLIGHT MR ANGIOGRAPHY OF THE BRAIN WITH MAGNETIZATION TRANSFER CONTRAST [J].
EDELMAN, RR ;
AHN, SS ;
CHIEN, D ;
WEI, L ;
GOLDMANN, A ;
MANTELLO, M ;
KRAMER, J ;
KLEEFIELD, J .
RADIOLOGY, 1992, 184 (02) :395-399
[10]  
*EUR CAR SURG TRIA, 1991, LANCET, V337, P1235