Small animal PET: aspects of performance assessment

被引:43
作者
Weber, S
Bauer, A
机构
[1] Forschungszentrum Julich, Cent Inst Elect, D-52425 Julich, Germany
[2] Forschungszentrum Julich, Res Ctr, Inst Med, D-5170 Julich, Germany
关键词
D O I
10.1007/s00259-004-1683-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dedicated small animal positron emission tomography (PET) systems are increasingly prevalent in industry (e.g. for preclinical drug development) and biological research. Such systems permit researchers to perform animal studies of a longitudinal design characterised by repeated measurements in single animals. With the advent of commercial systems, scanners have become readily available and increasingly popular. As a consequence, technical specifications are becoming more diverse, making scanner systems less broadly applicable. The investigator has, therefore, to make a decision regarding which type of scanner is most suitable for the intended experiments. This decision should be based on gantry characteristics and the physical performance. The first few steps have been taken towards standardisation of the assessment of performance characteristics of dedicated animal PET systems, though such assessment is not yet routinely implemented. In this review, we describe current methods of evaluation of physical performance parameters of small animal PET scanners. Effects of methodologically different approaches on the results are assessed. It is underscored that particular attention has to be paid to spatial resolution, sensitivity, scatter fraction and count rate performance. Differences in performance measurement methods are described with regard to commercially available systems, namely the Concorde MicroPET systems P4 and R4 and the quad-HIDAC. Lastly, consequences of differences in scanner performance parameters are rated with respect to applications of small animal PET.
引用
收藏
页码:1545 / 1555
页数:11
相关论文
共 46 条
[1]  
[Anonymous], PRECISION MEASUREMEN
[2]   Optimization of noise-equivalent count rates in 3D PET [J].
Badawi, RD ;
Marsden, PK ;
Cronin, BF ;
Sutcliffe, JL ;
Maisey, MN .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (09) :1755-1776
[3]   A METHOD FOR MEASURING THE ABSOLUTE SENSITIVITY OF POSITRON EMISSION TOMOGRAPHIC SCANNERS [J].
BAILEY, DL ;
JONES, T ;
SPINKS, TJ .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1991, 18 (06) :374-379
[4]   Three-dimensional performance of a small-diameter positron emission tomograph [J].
Bloomfield, PM ;
Myers, R ;
Hume, SP ;
Spinks, TJ ;
Lammertsma, AA ;
Jones, T .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (02) :389-400
[5]   THE DESIGN AND PHYSICAL CHARACTERISTICS OF A SMALL ANIMAL POSITRON EMISSION TOMOGRAPH [J].
BLOOMFIELD, PM ;
RAJESWARAN, S ;
SPINKS, TJ ;
HUME, SP ;
MYERS, R ;
ASHWORTH, S ;
CLIFFORD, KM ;
JONES, WF ;
BYARS, LG ;
YOUNG, J ;
ANDREACO, M ;
WILLIAMS, CW ;
LAMMERTSMA, AA ;
JONES, T .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (06) :1105-1126
[6]   Design and physical characteristics of a small animal PET using BaF2 crystals and a photosensitive wire chamber [J].
Bruyndonckx, P ;
Liu, X ;
Rajeswaran, S ;
Smolik, W ;
Tavernier, S ;
Zhang, SP .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 382 (03) :589-600
[7]   Performance study of a 3D small animal PET scanner based on BaF2 crystals and a photo sensitive wire chamber [J].
Bruyndonckx, P ;
Liu, XA ;
Tavernier, S ;
Zhang, SP .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 392 (1-3) :407-413
[8]   Molecular imaging of small animals with dedicated PET tomographs [J].
Chatziioannou, AF .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2002, 29 (01) :98-114
[9]  
Chatziioannou AF, 1999, J NUCL MED, V40, P1164
[10]   Fundamentals of positron emission tomography and applications in preclinical drug development [J].
Cherry, SR .
JOURNAL OF CLINICAL PHARMACOLOGY, 2001, 41 (05) :482-491