Determination of thiols following their separation by CZE with amperometric detection at a carbon electrode

被引:65
作者
Wang, A [1 ]
Zhang, L [1 ]
Zhang, S [1 ]
Fang, Y [1 ]
机构
[1] E China Normal Univ, Dept Chem, Shanghai 20062, Peoples R China
关键词
capillary zone electrophoresis; amperometric detection; thiols; cysteine; glutathione; methimazole; 6-thiopurine;
D O I
10.1016/S0731-7085(00)00326-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The amperometric detection (AD) employing a carbon disk electrode as a working electrode to determine the thiol compounds, including cysteine (CYS), glutathione (GSH), 6-thiopurine (TP), and methimazole (MMI), following their separation by capillary zone electrophoresis (CZE) is described in this paper. The detection potential was chosen at +1100 mV and all analytes exhibit good response at this potential on the carbon disk electrode. The reproducibility, linearity, and recovery were evaluated under the optimum conditions. The four analytes can be baseline resolved within 20 min and the detection limits reached about 10(-6) mol/l of magnitude. The method was applied to the separation and determination of the actual thiol samples and the analytical results were satisfactory. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:429 / 436
页数:8
相关论文
共 29 条
[21]  
REYNOLDS EF, 1989, MARTINDALE
[22]  
RUSSOIN A, 1988, METHODS BIOCH ANAL, V33
[23]   CAPILLARY ZONE ELECTROPHORETIC DETECTION OF BIOLOGICAL THIOLS AND THEIR S-NITROSATED DERIVATIVES [J].
STAMLER, JS ;
LOSCALZO, J .
ANALYTICAL CHEMISTRY, 1992, 64 (07) :779-785
[24]   COLORIMETRIC METHODS FOR THE ASSAY OF CARBIMAZOLE IN DRUG FORMULATIONS USING DICHROMATE AND MOLYBDATE [J].
SULTAN, SM .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1992, 10 (10-12) :1059-1062
[25]   ION-PAIR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF CYSTEINE AND METABOLICALLY RELATED-COMPOUNDS IN THE FORM OF THEIR S-PYRIDINIUM DERIVATIVES [J].
SYPNIEWSKI, S ;
BALD, E .
JOURNAL OF CHROMATOGRAPHY A, 1994, 676 (02) :321-330
[26]   CATHODIC ADSORPTIVE STRIPPING VOLTAMMETRY OF 6-THIOPURINE IN ABSENCE AND PRESENCE OF SOME METAL-IONS [J].
TEMERK, YM ;
AHMED, ZA ;
AHMED, ME ;
IBRAHIM, MS ;
KAMAL, MM .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 345 (11) :733-736
[27]   Separation and determination of the active ingredients in tablets of composite sulphonamides by capillary zone electrophoresis with amperometric detection [J].
Wang, AB ;
Gong, FY ;
Li, HF ;
Fang, YZ .
ANALYTICA CHIMICA ACTA, 1999, 386 (03) :265-269
[28]   IDENTIFICATION OF PHOSPHOCYSTEINE BY ELECTROSPRAY MASS-SPECTROMETRY COMBINED WITH EDMAN DEGRADATION [J].
WEIGT, C ;
KORTE, H ;
POGGE, R ;
VONSTRANDMANN, RP ;
HENGSTENBERG, W ;
MEYER, HE .
JOURNAL OF CHROMATOGRAPHY A, 1995, 712 (01) :141-147
[29]   Determination of thiocompounds by liquid chromatography with amperometric detection at a Nafion indium hexacyanoferrate film modified electrode [J].
Zhang, S ;
Sun, WL ;
Zhang, W ;
Qi, WY ;
Jin, LT ;
Yamamoto, K ;
Tao, SG ;
Jin, JY .
ANALYTICA CHIMICA ACTA, 1999, 386 (1-2) :21-30