Generalized 3D nonlinear transformations for medical imaging: an object-oriented implementation in VTK

被引:29
作者
Gobbi, DG
Peters, TM
机构
[1] John P Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[2] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
基金
加拿大健康研究院;
关键词
medical imaging; nonlinear transformation; thin-plate splines; visualization; ultrasound; surgery;
D O I
10.1016/S0895-6111(02)00091-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have contributed an efficient, object-oriented implementation of 3D nonlinear transformations to the Visualization Toolkit that can be applied to a wide variety of data types, including images and polygonal meshes. The transformations are performed via thin-plate splines or via interpolation of a regular lattice of displacement vectors, and are part of a framework that is easily extensible to other nonlinear transformation types. In this paper we demonstrate application of these transformations in medical imaging in general and image-guided surgery in particular, and present a series of performance benchmarks. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:255 / 265
页数:11
相关论文
共 15 条
[1]   Shape and the information in medical images: A decade of the morphometric synthesis [J].
Bookstein, FL .
COMPUTER VISION AND IMAGE UNDERSTANDING, 1997, 66 (02) :97-118
[2]  
Bucholz RD, 1997, LECT NOTES COMPUT SC, V1205, P459, DOI 10.1007/BFb0029268
[3]   Intraoperative ultrasound for guidance and tissue shift correction in image-guided neurosurgery [J].
Comeau, RM ;
Sadikot, AF ;
Fenster, A ;
Peters, TM .
MEDICAL PHYSICS, 2000, 27 (04) :787-800
[4]  
FINNIS K, 2002, IEEE T MED IMAGING, V21
[5]  
Finnis KW, 2000, LECT NOTES COMPUT SC, V1935, P1
[6]   Correlation of pre-operative MRI and intra-operative 3D ultrasound to measure brain tissue shift [J].
Gobbi, DG ;
Lee, BKH ;
Peters, TM .
MEDICAL IMAGING 2001: VISUALIZATION, DISPLAY, AND IMAGE-GUIDED PROCEDURES, 2001, 4319 :264-271
[7]  
Gobbi DG, 2000, LECT NOTES COMPUT SC, V1935, P106
[8]   Intraoperative three-dimensional ultrasonography: An approach to register brain shift using multidimensional image processing [J].
Jodicke, A ;
Deinsberger, W ;
Erbe, H ;
Kriete, A ;
Boker, DK .
MINIMALLY INVASIVE NEUROSURGERY, 1998, 41 (01) :13-19
[9]  
Press WH, 1993, NUMERICAL RECIPES C
[10]   Intraoperative brain shift and deformation: A quantitative analysis of cortical displacement in 28 cases [J].
Roberts, DW ;
Hartov, A ;