The biomechanics of biodegradable versus titanium interference screw fixation for anterior cruciate ligament augmentation and reconstruction

被引:15
作者
Ettinger, Max [1 ]
Schumacher, Diana [1 ]
Calliess, Tilman [1 ]
Dratzidis, Antonios [1 ]
Ezechieli, Marco [1 ]
Hurschler, Christof [2 ]
Becher, Christoph [1 ]
机构
[1] Hannover Med Sch, Dept Orthopaed Surg, D-30625 Hannover, Germany
[2] Hannover Med Sch, Dept Biomech & Biomat, D-30625 Hannover, Germany
关键词
LARS; ACL reconstruction; ACL biomechanics; Interference screw; HAMSTRING TENDON GRAFT; STRENGTH;
D O I
10.1007/s00264-014-2483-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Purpose The ligament augmentation and reconstruction system (LARS) is one of the options available for anterior cruciate ligament (ACL) reconstruction. To date, however, there are no published data regarding the biomechanical properties of LARS fixation for ACL reconstruction. The aim of this study was to investigate the biomechanical properties of various LARS interference-screw fixations. Methods A total of 100 LARS ligaments were fixed in porcine femurs with five different interference screws (four biodegradable screws and one titanium interference screw) introduced from inside-out or extra-articularly outside-in. Each group consisted of ten specimens. The constructs were cyclically stretched and subsequently loaded until failure. We evaluated the maximum load before failure, elongation during cyclic loading, stiffness, and failure mode. Results Elongation during cyclical loading for all devices tested was significantly larger between the first and 20th cycles than between the 20th and 500th cycles (p < 0.05). Maximum failure load was not significantly lower for the biodegradable screws than for the titanium screws (p > 0.05). All specimens failed because of ligament pull-out from the bony tunnel. Conclusions Our findings suggest that biomechanical secure fixation of the LARS for ACL reconstruction can be achieved using either biodegradable or titanium interference screws. The stability of fixation is independent of the approach, type of investigation, and type of fixation (extra-articular outside-in or intra-articular inside-out).
引用
收藏
页码:2499 / 2503
页数:5
相关论文
共 21 条
[1]
Graft fixation in cruciate ligament reconstruction [J].
Brand, J ;
Weiler, A ;
Caborn, DNM ;
Brown, CH ;
Johnson, DL .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2000, 28 (05) :761-774
[2]
Soft-tissue interference fixation: Bioabsorbable screw versus metal screw [J].
Brand, JC ;
Nyland, J ;
Caborn, DNM ;
Johnson, DL .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (08) :911-916
[3]
Graft-bone motion and tensile properties of hamstring and patellar tendon anterior cruciate ligament femoral graft fixation under cyclic loading [J].
Brown, CH ;
Wilson, DR ;
Hecker, AT ;
Ferragamo, M .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2004, 20 (09) :922-935
[4]
Biomechanical properties of femoral posterior cruciate ligament fixations [J].
Ettinger, M. ;
Petri, M. ;
Haag, K. T. ;
Brand, S. ;
Dratzidis, A. ;
Hurschler, C. ;
Krettek, C. ;
Jagodzinski, M. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (09) :2040-2047
[5]
The fixation strength of tibial PCL press-fit reconstructions [J].
Ettinger, M. ;
Wehrhahn, T. ;
Petri, M. ;
Liodakis, E. ;
Olender, G. ;
Albrecht, U. -V. ;
Hurschler, C. ;
Krettek, C. ;
Jagodzinski, M. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (02) :308-314
[6]
Current concepts review - The science of reconstruction of the anterior cruciate ligament [J].
Frank, CB ;
Jackson, DW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (10) :1556-1576
[7]
The use of the LARS artificial ligament to augment a short or undersized ACL hamstrings tendon graft [J].
Hamido, F. ;
Misfer, A. K. ;
Al Harran, H. ;
Khadrawe, T. A. ;
Soliman, A. ;
Talaat, A. ;
Awad, A. ;
Khairat, S. .
KNEE, 2011, 18 (06) :373-378
[8]
Bone tunnel enlargement after anterior cruciate ligament reconstruction: Fact or fiction? [J].
Höher J. ;
Möller H.D. ;
Fu F.H. .
Knee Surgery, Sports Traumatology, Arthroscopy, 1998, 6 (4) :231-240
[9]
Biomechanical analysis of press-fit fixation of anterior cruciate ligament transplants [J].
Jagodzinski, M. ;
Ettinger, M. ;
Haasper, C. ;
Hankemeier, S. ;
Breitmeier, D. ;
Hurschler, C. ;
Krettek, C. .
UNFALLCHIRURG, 2010, 113 (07) :532-539
[10]
The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction -: Part I:: Femoral site [J].
Kousa, P ;
Järvinen, TLN ;
Vihavainen, M ;
Kannus, P ;
Järvinen, M .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2003, 31 (02) :174-181