Amperometric screen-printed biosensor arrays with co-immobilised oxidoreductases and cholinesterases

被引:55
作者
Solná, R
Dock, E
Christenson, A
Winther-Nielsen, M
Carlsson, C
Emnéus, J
Ruzgas, T
Skládal, P
机构
[1] Masaryk Univ, Dept Biochem, CS-61137 Brno, Czech Republic
[2] Lund Univ, Dept Analyt Chem, S-22100 Lund, Sweden
[3] DHI Water & Environm, DK-2970 Horsholm, Denmark
[4] ANOX, S-22647 Lund, Sweden
关键词
amperometric multienzyme sensor; steady state system; cholinesterase; oxidoreductase; phenoks; pesticides; wastewater; multivariate-analysis;
D O I
10.1016/j.aca.2004.10.022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Amperometric screen-printed biosensor arrays for detection of pesticides (organophosphates and carbamates) and phenols have been developed. Cholinesterases (AChE and BChE), tyrosinase (TYR), peroxidases (SBP. soybean and HRP. horseradish) and cellobiose dehydrogenase (CDH) were combined on the same array consisting of one Ag/AgCl reference electrode surrounded by eight radially distributed working electrodes of either carbon or platinum. Mainly cross-linking with glutaraldehyde was employed for enzyme immobilisation. The substrates for the enzymes were acetylthiocholine for cholinesterases (ChEs), cellobiose for CDH and hydrogen peroxide for peroxidases. Hydrogen peroxide was generated in the presence of glucose by co-immobilised glucose oxidase (GOx). All measurements were performed in an electrochemical steady state system specially constructed for eight channel screen-printed electrode arrays. The achieved relative standard deviation values calculated for different enzyme substrates (10 measurements) were typically below 7% and one assay was completed within less than 10 min. The detection limits for pesticides and phenols were in the nanomolar and micromolar ranges, respectively. The developed biosensor array was evaluated on wastewater samples. To simplify interpretation of results. the measured data were created with multivariate analysis-principal component analysis (PCA). (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:9 / 19
页数:11
相关论文
共 39 条
  • [1] Pesticide determination in tap water and juice samples using disposable amperometric biosensors made using thick-film technology
    Albareda-Sirvent, M
    Merkoçi, A
    Alegret, S
    [J]. ANALYTICA CHIMICA ACTA, 2001, 442 (01) : 35 - 44
  • [2] [Anonymous], AG TOX SUBST DIS REG
  • [3] Multibiosensor based on enzyme inhibition analysis for determination of different toxic substances
    Arkhypova, VN
    Dzyadevych, SV
    Soldatkin, AP
    El'skaya, AV
    Jaffrezic-Renault, N
    Jaffrezic, H
    Martelet, C
    [J]. TALANTA, 2001, 55 (05) : 919 - 927
  • [4] Arufe MI, 2000, BIOCHEM EDUC, V28, P174
  • [5] A disposable multielectrode biosensor for rapid simultaneous detection of the insecticides paraoxon and carbofuran at high resolution
    Bachmann, TT
    Schmid, RD
    [J]. ANALYTICA CHIMICA ACTA, 1999, 401 (1-2) : 95 - 103
  • [6] Cellobiose dehydrogenase - an extracellular fungal flavocytochrome
    Cameron, MD
    Aust, SD
    [J]. ENZYME AND MICROBIAL TECHNOLOGY, 2001, 28 (2-3) : 129 - 138
  • [7] Amperometric flow-injection determination of phenolic compounds at self-assembled monolayer-based tyrosinase biosensors
    Campuzano, S
    Serra, B
    Pedrero, M
    de Villena, FJM
    Pingarrón, JM
    [J]. ANALYTICA CHIMICA ACTA, 2003, 494 (1-2) : 187 - 197
  • [8] Disposable tyrosinase-peroxidase bi-enzyme sensor for amperometric detection of phenols
    Chang, SC
    Rawson, K
    McNeil, CJ
    [J]. BIOSENSORS & BIOELECTRONICS, 2002, 17 (11-12) : 1015 - 1023
  • [9] Sol-gel cholinesterase biosensor for organophosphorus pesticide fluorimetric analysis
    Diaz, AN
    Peinado, MCR
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1997, 39 (1-3) : 426 - 431
  • [10] DOCK E, IN PRESS ANAL CHIM A