Electrosynthesized non-conducting polymers as permselective membranes in amperometric enzyme electrodes: a glucose biosensor based on a co-crosslinked glucose oxidase overoxidized polypyrrole bilayer

被引:83
作者
Guerrieri, A
De Benedetto, GE
Palmisano, F
Zambonin, PG
机构
[1] Univ Basilicata, Dipartimento Chim, I-85100 Potenza, Italy
[2] Univ Bari, Dipartimento Chim, I-70126 Bari, Italy
关键词
enzyme immobilization; biosensor; overoxidized polypyrrole; enzyme co-crosslinking; glucose; flow-injection analysis; serum;
D O I
10.1016/S0956-5663(97)00064-X
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A glucose amperometric biosensor based on glucose oxidase immobilized on an overoxidized polypyrrole (PPyox) platinum modified electrode, by glutaraldehyde co-crosslinking with bovine serum albumine, is described. The advantages of covalent immobilization techniques (e.g., high loading and long-term stability of the enzyme) are coupled with the excellent interferent rejection of electrosynthesized non-conducting polymers. The sensor showed an apparent Michaelis-Menten constant of 16 +/- 0.8 mM, a maximum current density of 490 mu A/cm(2) and a shelf lifetime of at least 3 months. Ascorbate, urate, cysteine and acetaminophen at their maximum physiological concentrations produced a glucose bias in the low micromolar range. Flow-injection response was linear up to 20 mM glucose with typical sensitivity of 84.0 +/- 1.5 nA/mM. The sensor was tested for glucose determination of untreated serum samples from both normal and diabetic subjects; results of amperometric assay compared well with those obtained by a standard enzymatic-colorimetric method. (C) 1998 Published by Elsevier Science Limited.
引用
收藏
页码:103 / 112
页数:10
相关论文
共 24 条
[1]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .1. THEORY [J].
BARTLETT, PN ;
WHITAKER, RG .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 224 (1-2) :27-35
[2]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .3. IMMOBILIZATION OF GLUCOSE-OXIDASE IN THIN-FILMS OF ELECTROCHEMICALLY POLYMERIZED PHENOLS [J].
BARTLETT, PN ;
TEBBUTT, P ;
TYRRELL, CH .
ANALYTICAL CHEMISTRY, 1992, 64 (02) :138-142
[3]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .2. GLUCOSE-OXIDASE IMMOBILIZED IN POLY-N-METHYLPYRROLE [J].
BARTLETT, PN ;
WHITAKER, RG .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 224 (1-2) :37-48
[4]  
BARTLETT PN, 1993, J ELECTROANAL CHEM, V362, P1
[5]   INTERFERENCE-FREE GLUCOSE SENSOR BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN AN OVEROXIDIZED NONCONDUCTING POLYPYRROLE FILM [J].
CENTONZE, D ;
GUERRIERI, A ;
MALITESTA, C ;
PALMISANO, F ;
ZAMBONIN, PG .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (09) :729-733
[6]  
CENTONZE D, 1992, ANN CHIM-ROME, V82, P219
[7]  
CORNISHBOWDEN A, 1976, PRINCIPLES ENZYMES K
[8]   ELECTROANALYTICAL X-RAY PHOTOELECTRON-SPECTROSCOPY INVESTIGATION ON GLUCOSE-OXIDASE ADSORBED ON PLATINUM [J].
DEBENEDETTO, GE ;
MALITESTA, C ;
ZAMBONIN, CG .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1994, 90 (11) :1495-1499
[9]   OPTIMIZATION OF A POLYPYRROLE GLUCOSE-OXIDASE BIOSENSOR [J].
FORTIER, G ;
BRASSARD, E ;
BELANGER, D .
BIOSENSORS & BIOELECTRONICS, 1990, 5 (06) :473-490
[10]  
GIESE RJ, 1991, BIOSENS BIOELECTRON, V6, P151