Accurate and efficient image intensifier distortion correction algorithm for volume tomographic angiography

被引:8
作者
Wang, XH [1 ]
Ning, RL [1 ]
机构
[1] Univ Rochester, Med Ctr, Dept Radiol, Rochester, NY 14642 USA
关键词
image intensifier; pincushion distortion; S-distortion; finite element analysis; three-dimensional tomographic reconstruction;
D O I
10.1117/1.601930
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The recent advance in image intensifier based volume tomographic angiography has stirred a significant interest in the development of accurate and efficient algorithms to correct image intensifier distortions. An algorithm and its calibration protocol are developed to correct the distortion caused by the image intensifier-CCD camera imaging chain in a single step regardless of distortion sources. This algorithm first partitions a distorted image into small quadrilateral regions, then maps each region individually to the corrected image using the corresponding bilinear functions. The general applicable parameters of these bilinear functions can be obtained using a specially designed grid phantom. The algorithm and the calibration protocol are tested using this grid phantom on a newly built image intensifier based volume tomographic angiography imaging system. The maximum distortion error is reduced from 5.96 mm before correction to 0.05 mm after correction. Further validation of the proposed algorithm is performed through three-dimensional tomographic reconstructions of a vascular phantom and animal studies. The reconstruction results indicate that the accuracy of the algorithm and the calibration protocol is acceptable for volume tomographic angiography. This algorithm can also be applied to radiation therapy and stereosurgical treatment planning where image intensifier distortions must be corrected. (C) 1998 Society of Photo-Optical Instrumentation Engineers. [S0091-3286(98)03603-4].
引用
收藏
页码:977 / 983
页数:7
相关论文
共 14 条
  • [1] ANALYSIS AND CORRECTION OF IMPERFECTIONS IN THE IMAGE INTENSIFIER-TV-DIGITIZER IMAGING CHAIN
    BOONE, JM
    SEIBERT, JA
    BARRETT, WA
    BLOOD, EA
    [J]. MEDICAL PHYSICS, 1991, 18 (02) : 236 - 242
  • [2] IMAGE INTENSIFIER DISTORTION CORRECTION
    CHAKRABORTY, DP
    [J]. MEDICAL PHYSICS, 1987, 14 (02) : 249 - 252
  • [3] PRACTICAL CONE-BEAM ALGORITHM
    FELDKAMP, LA
    DAVIS, LC
    KRESS, JW
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06): : 612 - 619
  • [4] GONZALEZ RC, 1993, DIGITAL IMAGE PROCES, P298
  • [5] A HIGH-RESOLUTION XRII-BASED QUANTITATIVE VOLUME CT SCANNER
    HOLDSWORTH, DW
    DRANGOVA, M
    FENSTER, A
    [J]. MEDICAL PHYSICS, 1993, 20 (02) : 449 - 462
  • [6] MOHR GA, 1992, FINITE ELEMENTS SOLI, P98
  • [7] Image intensifier-based computed tomography volume scanner for angiography
    Ning, R
    Kruger, RA
    [J]. ACADEMIC RADIOLOGY, 1996, 3 (04) : 344 - 350
  • [8] NING R, 1994, P SOC PHOTO-OPT INS, V2163, P199, DOI 10.1117/12.174257
  • [9] NING R, 1988, SPIE, V914, P282
  • [10] An image intensifier-based volume tomographic angiography imaging system: Work in progress
    Ning, RL
    Zhang, DF
    Wang, XH
    Conover, DL
    [J]. PHYSICS OF MEDICAL IMAGING: MEDICAL IMAGING 1996, 1996, 2708 : 328 - 339