Plasma-polymerized surfaces for culture of human keratinocytes and transfer of cells to an in vitro wound-bed model

被引:80
作者
Haddow, DB
Steele, DA
Short, RD
Dawson, RA
MacNeil, S
机构
[1] Univ Sheffield, Dept Mat Engn, Lab Surface & Interface Anal, Sheffield S1 3JD, S Yorkshire, England
[2] Univ Sheffield, No Gen Hosp, Div Clin Sci, Med Sect, Sheffield S5 7AU, S Yorkshire, England
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A | 2003年 / 64A卷 / 01期
关键词
keratinocyte; plasma polymer; plasma polymerization; cell attachment; cell transfer; wound healing;
D O I
10.1002/jbm.a.10356
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this study was to develop plasma-polymerized surfaces suitable for the attachment and culture of human keratinocytes and that would allow their subsequent transfer to a wound-bed model. Keratinocyte attachment has been assessed on a carrier polymer, either untreated or treated with a hydrocarbon plasma polymer, collagen I, or carboxylic-acid-containing plasma copolymers. Cell attachment was poor on the "bare" carrier poly mer and hydrocarbon plasma polymer (PP) surfaces. Cell attachment was good and comparable on collagen I-coated carrier polymer and carrier polymer plasma coated with carboxylic acid functionalities. After 24 h of cell culture, surfaces were inverted so that cells were adjacent to a deepidermalized dermis (DED) for 4 days. After 4 days in contact with DED, the surfaces were removed and the level of residual cells and cells transferred to DED were assessed using a cell viability assay. Cell transfer from the collagen I-coated surface was on the order of 90%. Transfer from the carrier polymer surface and the hydrocarbon-coated surface was poor while cells cultured on acid-containing surfaces showed high levels of transfer. Cell transfer was greatest from those surfaces containing the highest level of acid functionality (ca. 21%). Cell transfer was not significantly affected by the choice of carrier polymer material although some sample-to-sample variation was seen. To determine that plasma-polymerized surfaces could be used clinically, selected samples were sterilized with ethylene oxide. Subsequent analysis and cell culture indicated that the surface chemistry and cell-transfer capability of these plasma-polymerized surfaces were unaffected by the sterilization procedure. Plasma-polymerized carboxylic-acid-containing surfaces show great promise in the field of wound healing, encouraging keratinocyte attachment and permitting keratinocyte transfer to a wound bed. (C) 2002 Wiley Periodicals, Inc.
引用
收藏
页码:80 / 87
页数:8
相关论文
共 20 条
[11]   GROWTH OF HUMAN-CELLS ON PLASMA POLYMERS - PUTATIVE ROLE OF AMINE AND AMIDE GROUPS [J].
GRIESSER, HJ ;
CHATELIER, RC ;
GENGENBACH, TR ;
JOHNSON, G ;
STEELE, JG .
JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 1994, 5 (06) :531-554
[12]  
Haddow DB, 1999, J BIOMED MATER RES, V47, P379, DOI 10.1002/(SICI)1097-4636(19991205)47:3<379::AID-JBM13>3.0.CO
[13]  
2-#
[14]   CULTURED AUTOLOGOUS KERATINOCYTES IN FIBRIN GLUE SUSPENSION, EXCLUSIVELY AND COMBINED WITH STS-ALLOGRAFT (PRELIMINARY CLINICAL AND HISTOLOGICAL REPORT OF A NEW TECHNIQUE) [J].
KAISER, HW ;
STARK, GB ;
KOPP, J ;
BALCERKIEWICZ, A ;
SPILKER, G ;
KREYSEL, HW .
BURNS, 1994, 20 (01) :23-29
[15]   Characterization of plasma polymers of acrylic acid and propanoic acid [J].
OToole, L ;
Beck, AJ ;
Short, RD .
MACROMOLECULES, 1996, 29 (15) :5172-5177
[16]   Endothelial cell growth and protein adsorption on terminally functionalized, self-assembled monolayers of alkanethiolates on gold [J].
Tidwell, CD ;
Ertel, SI ;
Ratner, BD ;
Tarasevich, BJ ;
Atre, S ;
Allara, DL .
LANGMUIR, 1997, 13 (13) :3404-3413
[17]   Accelerated photodegradation of poly(vinyl chloride) [J].
Torikai, A ;
Hasegawa, H .
POLYMER DEGRADATION AND STABILITY, 1999, 63 (03) :441-445
[18]   Improving γ-radiation stability of PVC -: A review [J].
Wang, Q ;
Nagy, S .
JOURNAL OF VINYL & ADDITIVE TECHNOLOGY, 1999, 5 (01) :4-11
[19]   Adsorption of vitronectin, collagen and immunoglobulin-G to plasma polymer surfaces by enzyme linked immunosorbent assay (ELISA) [J].
Whittle, JD ;
Bullett, NA ;
Short, RD ;
Douglas, CWI ;
Hollander, AP ;
Davies, J .
JOURNAL OF MATERIALS CHEMISTRY, 2002, 12 (09) :2726-2732
[20]  
WIGHT TN, 1992, ANN REV CELL BIOL, V8, P365