Dosimetric evaluation of the clinical implementation of the first commercial IMRT Monte Carlo treatment planning system at 6 MV

被引:37
作者
Heath, E
Seuntjens, J
Sheikh-Bagheri, D
机构
[1] McGill Univ, Med Phys Unit, Montreal, PQ H3G 1A4, Canada
[2] NOMOS, Div Oncol, N Amer Sci, Cranberry Township, PA USA
关键词
Monte Carlo; dose calculation; radiation therapy; treatment planning; photon beams; IMRT;
D O I
10.1118/1.1786172
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this work we dosimetrically evaluated the clinical implementation of a commercial Monte Carlo treatment planning software (PEREGRINE, North American Scientific, Cranberry Township, PA) intended for quality assurance (QA) of intensity modulated radiation therapy treatment plans. Dose profiles calculated in homogeneous and heterogeneous phantoms using this system were compared to both measurements and simulations using the EGSnrc Monte Carlo code for the 6 MV beam of a Varian CL21EX linear accelerator. For simple jaw-defined fields, calculations agree within 2% of the dose at d(max) with measurements in homogeneous phantoms with the exception of the buildup region where the calculations overestimate the dose by up to 8%. In heterogeneous lung and bone phantoms the agreement is within 3%, on average, up to 5% for a 1 x 1 cm(2) field. We tested two consecutive implementations of the MLC model. After matching the calculated and measured MLC leakage, simulations of static and dynamic MLC-defined fields using the most recent MLC model agreed to within 2% with measurements. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:2771 / 2779
页数:9
相关论文
共 26 条
[1]  
*AAPM, 2001, 72 APPM
[2]  
ABDELRAHMAN W, IN PRESS MED PHYS
[3]  
[Anonymous], 1993, 50 ICRU
[4]   Monte Carlo study of correction factors for Spencer-Attix cavity theory at photon energies at or above 100 keV [J].
Borg, J ;
Kawrakow, I ;
Rogers, DWO ;
Seuntjens, JP .
MEDICAL PHYSICS, 2000, 27 (08) :1804-1813
[5]   A FINITE-SIZE PENCIL BEAM MODEL FOR PHOTON DOSE CALCULATIONS IN 3 DIMENSIONS [J].
BOURLAND, JD ;
CHANEY, EL .
MEDICAL PHYSICS, 1992, 19 (06) :1401-1412
[6]   Evaluation of the first commercial Monte Carlo dose calculation engine for electron beam treatment planning [J].
Cygler, JE ;
Daskalov, GM ;
Chan, GH ;
Ding, GX .
MEDICAL PHYSICS, 2004, 31 (01) :142-153
[7]   Comparison of measured and Monte Carlo calculated dose distributions in inhomogeneous phantoms in clinical electron beams [J].
Doucet, R ;
Olivares, M ;
DeBlois, F ;
Podgorsak, EB ;
Kawrakow, I ;
Seuntjens, J .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (15) :2339-2354
[8]   BACKSCATTER INTO THE BEAM MONITOR CHAMBER - IMPLICATIONS FOR DOSIMETRY OF ASYMMETRIC COLLIMATORS [J].
DUZENLI, C ;
MCCLEAN, B ;
FIELD, C .
MEDICAL PHYSICS, 1993, 20 (02) :363-367
[9]  
HARMANN CL, 2001, MED PHYS, V28, P1322
[10]  
HARMS W, 1997, SPECIFICATION TAPE N