Evaluation of the first commercial Monte Carlo dose calculation engine for electron beam treatment planning

被引:75
作者
Cygler, JE
Daskalov, GM
Chan, GH
Ding, GX
机构
[1] Ottawa Reg Canc Ctr, Dept Phys Med, Ottawa, ON K1H 1C4, Canada
[2] British Columbia Canc Agcy, Fraser Valley Canc Ctr, Clin Phys, Surrey, BC V3V 1Z2, Canada
关键词
electron beam; Monte Carlo treatment planning; inhomogeneous phantoms; monitor unit calculations;
D O I
10.1118/1.1633105
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study is to perform a clinical evaluation of the first commercial (MDS Nordion, now Nucletron) treatment planning system for electron beams incorporating Monte Carlo dose calculation module. This software implements Kawrakow's VMC++ voxel-based Monte Carlo calculation algorithm. The accuracy of the dose distribution calculations is evaluated by direct comparisons with extensive sets of measured data in homogeneous and heterogeneous phantoms at different source-to-surface distances (SSDs) and gantry angles. We also verify the accuracy of the Monte Carlo module for monitor unit calculations in comparison with independent hand calculations for homogeneous water phantom at two different SSDs. All electron beams in the range 6-20 MeV are from a Siemens KD-2 linear accelerator. We used 10 000 or 50 000 histories/cm(2) in our Monte Carlo calculations, which led to about 2.5% and 1% relative standard error of the mean of the calculated dose. The dose calculation time depends on the number of histories, the number of voxels used to map the patient anatomy, the field size, and the beam energy. The typical run time of the Monte Carlo calculations ( 10 000 histories/cm(2)) is 1.02 min on a 2.2 GHz Pentium 4 Xeon computer for a 9 MeV beam, 10 X 10 cm(2) field size, incident on the phantom 15 X 15 X 10 cm(3) consisting of 31 CT slices and voxels size of 3 X 3 X 3 mm(3) (total of 486 720 voxels). We find good agreement (discrepancies smaller than 5%) for most of the tested dose distributions. We also find excellent agreement (discrepancies of 2.5% or less) for the monitor unit calculations relative to the independent manual calculations. The accuracy of monitor unit calculations does not depend on the SSD used, which allows the use of one virtual machine for each beam energy for all arbitrary SSDs. In some cases the test results are found to be sensitive to the voxel size applied such that bigger systematic errors ( > 5 %) occur when large voxel sizes interfere with the extensions of heterogeneities or dose gradients because of differences between the experimental and calculated geometries. Therefore, user control over voxelization is important for high accuracy electron dose calculations. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:142 / 153
页数:12
相关论文
共 25 条
[1]  
Ahnesjo A., 2000, Radiotherapy and Oncology, V56, pS79
[2]  
ASELL M, 2001, RADIOTHER ONCOL, V61, pS27
[3]  
Bielajew A., 1990, The Dosimetry of Ionizing Radiation, Volume, P427
[4]   Practical approach to electron beam dosimetry at extended SSD [J].
Cygler, J ;
Li, XA ;
Ding, GX ;
Lawrence, E .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (08) :1505-1514
[5]   ELECTRON DOSE DISTRIBUTIONS IN EXPERIMENTAL PHANTOMS - A COMPARISON WITH 2D PENCIL BEAM CALCULATIONS [J].
CYGLER, J ;
BATTISTA, JJ ;
SCRIMGER, JW ;
MAH, E ;
ANTOLAK, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (09) :1073-1086
[6]   Evaluation of a commercial three-dimensional electron beam treatment planning system [J].
Ding, GX ;
Cygler, JE ;
Zhang, GG ;
Yu, MK .
MEDICAL PHYSICS, 1999, 26 (12) :2571-2580
[7]   Comparison of measured and Monte Carlo calculated dose distributions in inhomogeneous phantoms in clinical electron beams [J].
Doucet, R ;
Olivares, M ;
DeBlois, F ;
Podgorsak, EB ;
Kawrakow, I ;
Seuntjens, J .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (15) :2339-2354
[8]   A MONTE-CARLO INVESTIGATION OF ELECTRON-BEAM APPLICATOR SCATTER [J].
EBERT, MA ;
HOBAN, PW .
MEDICAL PHYSICS, 1995, 22 (09) :1431-1435
[9]   A MODEL FOR ELECTRON-BEAM APPLICATOR SCATTER [J].
EBERT, MA ;
HOBAN, PW .
MEDICAL PHYSICS, 1995, 22 (09) :1419-1429
[10]   Electron beam dose calculations with the VMC algorithm and the verification data of the NCI working group [J].
Fippel, M ;
Kawrakow, I ;
Friedrich, K .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (03) :501-520