Latex immunoagglutination assay for a vasculitis marker in a microfluidic device using static light scattering detection

被引:28
作者
Lucas, Lonnie J. [1 ]
Han, Jin-Hee [1 ]
Chesler, Jennine [1 ]
Yoon, Jeong-Yeol [1 ]
机构
[1] Univ Arizona, Dept Agr & Biosyst Engn, Tucson, AZ 85721 USA
基金
美国国家科学基金会;
关键词
immunoassay; lab-on-a-chip; microsphere; fiber optics; vasculitis; light scattering;
D O I
10.1016/j.bios.2006.10.029
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We have developed a microfluidic immunoassay device using fiber optics to detect static light scattering (SLS) of latex microsphere agglutination. A 400-mu m silica fiber was used to deliver blue light emitting diode (LED) or red laser light sources. A miniature, portable spectrometer was used to measure forward light scattering intensity collected by the same type of multi-mode fiber. To first show feasibility, anti-mouse IgG were used as target biomolecules and highly carboxylated polystyrene latex microspheres (510 nm) coated with mouse IgG were used as probes. Next, we tested for the vasculitis marker, anti-PR3, using the same type of microspheres coated with PR3 proteins. No false negatives or positives were observed. A limit of detection (LOD) of 50 ng mL(-1) was demonstrated for the vasculitis marker, anti-PR3. (Plasma samples from patients with vasculitis exhibited anti-PR3 at a median level of 380 ng mL(-1).) The optical detection system works without any fluorescence or chemiluminescence markers. The entire system proposed here is cost effective, small in size, and re-usable with simple rinsing. This may eventually lead to a portable, low-cost, re-useable, microfluidic, point of care immunoassay device. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:2216 / 2222
页数:7
相关论文
共 25 条
[1]   Increased neutrophil membrane expression and plasma level of proteinase 3 in systemic vasculitis are not a consequence of the-564 A/G promotor polymorphism [J].
Abdgawad, M ;
Hellmark, T ;
Gunnarsson, L ;
Westman, KWA ;
Segelmark, M .
CLINICAL AND EXPERIMENTAL IMMUNOLOGY, 2006, 145 (01) :63-70
[2]  
BANGS L, 1999, 204 BANGS LAB INC
[3]   New developments in particle-based immunoassays: Introduction [J].
Bangs, LB .
PURE AND APPLIED CHEMISTRY, 1996, 68 (10) :1873-1879
[4]   MEASUREMENTS OF PROTEINASE-3 AND ITS COMPLEXES WITH ALPHA(1)-PROTEINASE INHIBITOR AND ANTINEUTROPHIL CYTOPLASM ANTIBODIES (ANCA) IN PLASMA [J].
BASLUND, B ;
PETERSEN, J ;
PERMIN, H ;
WIIK, A ;
WIESLANDER, J .
JOURNAL OF IMMUNOLOGICAL METHODS, 1994, 175 (02) :215-225
[5]   Microfluidic interferometer -: art. no. 024103 [J].
Domachuk, P ;
Grillet, C ;
Ta'eed, V ;
Mägi, E ;
Bolger, J ;
Eggleton, BJ ;
Rodd, LE ;
Cooper-White, J .
APPLIED PHYSICS LETTERS, 2005, 86 (02) :024103-1
[6]   Bead-based immunoassays with microelectrode detection [J].
Farrell, S ;
Ronkainen-Matsuno, NJ ;
Halsall, HB ;
Heineman, WR .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (03) :358-367
[7]   Design for mixing using bubbles in branched microfluidic channels [J].
Garstecki, P ;
Fischbach, MA ;
Whitesides, GM .
APPLIED PHYSICS LETTERS, 2005, 86 (24) :1-3
[8]  
HAN JH, 2006, MARCH 10 12 2006 P 2
[9]  
Haugh R, 2006, HOSP HEALTH NETWORK, V80, P46
[10]   Variations in performance characteristics of commercial enzyme immunoassay kits for detection of antineutrophil cytoplasmic antibodies: what is the optimal cut off? [J].
Holle, JU ;
Hellmich, B ;
Backes, M ;
Gross, WL ;
Csernok, E .