Physical collection efficiency of filter materials for bacteria and viruses

被引:115
作者
Clark Burton, Nancy
Grinshpun, Sergey A.
Reponen, Tiina
机构
[1] NIOSH, Ctr Dis Control & Prevent, Cincinnati, OH 45226 USA
[2] Univ Cincinnati, Dept Environm Hlth, Cincinnati, OH 45267 USA
关键词
bacteriophages; collection efficiency; endospores; gelatin; polycarbonate; polytetrafluoroethylene;
D O I
10.1093/annhyg/mel073
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The purpose of this study was to determine the physical collection efficiency of commercially available filters for collecting airborne bacteria, viruses, and other particles in the 10-900 nm (nanometer) size range. Laboratory experiments with various polytetrafluoroethylene (PTFE), polycarbonate (PC) and gelatin filters in conjunction with Button (TM) Inhalable samplers and three-piece cassettes were undertaken. Both biological and non-biological test aerosols were used: Bacillus atrophaeus, MS2, polystyrene latex (PSL), and sodium chloride (NaCl). The B.atrophaeus endospores had an aerodynamic diameter of 900 nm, whereas MS2 virion particles ranged from 10 to 80 nm. Monodisperse 350 nm PSL particles were used as this size was believed to have the lowest filtration efficiency. NaCl solution (1% weight by volume) was used to create a polydisperse aerosol in the 10-600 nm range. The physical collection efficiency was determined by measuring particle concentrations size-selectively upstream and downstream of the filters. The PTFE and gelatin filters showed excellent collection efficiency (> 93%) for all of the test particles. The PC filters showed lower collection efficiency for small particles especially < 100 nm. Among the tested filters, the lowest collection efficiencies, 49 and 22%, were observed for 1 and 3-mu m pore size PC filters at the particle sizes of 47 and 63 nm, respectively. The results indicate that the effect of filter material is more significant for the size range of single virions than for bacteria. The effect of filter loading was examined by exposing filters to mixtures of PSL particles, which aimed at mimicking typical indoor dust levels and size distributions. A 4-h loading did not cause significant change in the physical collection efficiency of the tested filters.
引用
收藏
页码:143 / 151
页数:9
相关论文
共 40 条
[1]   Inactivation of viruses in bubbling processes utilized for personal bioaerosol monitoring [J].
Agranovski, IE ;
Safatov, AS ;
Borodulin, AI ;
Pyankov, OV ;
Petrishchenko, VA ;
Sergeev, AN ;
Agafonov, AP ;
Ignatiev, GM ;
Sergeev, AA ;
Agranovski, V .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2004, 70 (12) :6963-6967
[2]   New personal sampler for viable airborne viruses: feasibility study [J].
Agranovski, IE ;
Safatov, AS ;
Borodulin, AI ;
Pyankov, OV ;
Petrishchenko, VA ;
Sergeev, AN ;
Sergeev, AA ;
Agranovski, V ;
Grinshpun, SA .
JOURNAL OF AEROSOL SCIENCE, 2005, 36 (5-6) :609-617
[3]   Performance characteristics of the button personal inhalable aerosol sampler [J].
Aizenberg, V ;
Grinshpun, SA ;
Willeke, K ;
Smith, J ;
Baron, PA .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 2000, 61 (03) :398-404
[4]   Inactivation of MS-2 phage and poliovirus in groundwater [J].
Alvarez, ME ;
Aguilar, M ;
Fountain, A ;
Gonzalez, N ;
Rascon, O ;
Saenz, D .
CANADIAN JOURNAL OF MICROBIOLOGY, 2000, 46 (02) :159-165
[5]  
[Anonymous], PRINCIPLES PRACTICES
[6]   Do N95 respirators provide 95% protection level against airborne viruses, and how adequate are surgical masks? [J].
Balazy, A ;
Toivola, M ;
Adhikari, A ;
Sivasubramani, SK ;
Reponen, T ;
Grinshpun, SA .
AMERICAN JOURNAL OF INFECTION CONTROL, 2006, 34 (02) :51-57
[7]  
Belgrader P, 1998, CLIN CHEM, V44, P2191
[8]   Detection of airborne severe acute respiratory syndrome (SARS) coronavirus and environmental contamination in SARS outbreak units [J].
Booth, TF ;
Kournikakis, B ;
Bastien, N ;
Ho, J ;
Kobasa, D ;
Stadnyk, L ;
Li, Y ;
Spence, M ;
Paton, S ;
Henry, B ;
Mederski, B ;
White, D ;
Low, DE ;
McGeer, A ;
Simor, A ;
Vearncombe, M ;
Downey, J ;
Jamieson, FB ;
Tang, P ;
Plummer, F .
JOURNAL OF INFECTIOUS DISEASES, 2005, 191 (09) :1472-1477
[9]   Detection of molecular diversity in Bacillus atrophaeus by amplified fragment length polymorphism analysis [J].
Burke, SA ;
Wright, JD ;
Robinson, MK ;
Bronk, BV ;
Warren, RL .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2004, 70 (05) :2786-2790
[10]   The effect of filter material on bioaerosol collection of Bacillus subtilis spores used as a Bacillus anthracis simulant [J].
Burton, NC ;
Adhikari, A ;
Grinshpun, SA ;
Hornung, R ;
Reponen, T .
JOURNAL OF ENVIRONMENTAL MONITORING, 2005, 7 (05) :475-480