Development of robust multivariate calibration models

被引:31
作者
Thomas, EV
Ge, NX
机构
[1] Sandia Natl Labs, Stat & Human Factors Dept, Albuquerque, NM 87185 USA
[2] Bristol Myers Squibb, Princeton, NJ 08543 USA
关键词
calibration maintenance; chemometrics; diffuse reflectance spectroscopy; robust experimental design; signal-response system;
D O I
10.2307/1271449
中图分类号
O21 [概率论与数理统计]; C8 [统计学];
学科分类号
020208 ; 070103 ; 0714 ;
摘要
Multivariate calibration is frequently used for the quantitative analysis of a wide variety of materials using spectroscopy in the agricultural and food industries, manufacturing industries, medical sciences, and pharmaceutical industries. To date, most of the research activities in the multivariate calibration literature have focused on data analysis for model building and prediction with methods such as principal-components regression or partial least squares regression. As an alternative to focusing on data-analytic activities, we consider the ability of an experimental design to improve the robustness of the resulting calibration model. Through an example involving diffuse reflectance measurements, we illustrate how consideration of environmental and instrumental factors during the experimental design phase can result in a calibration model that is robust (against natural environmental and instrument variations) and easy to maintain. In this example, the analyte of interest produces a spectroscopic signal that is very weak in comparison to the environmental and instrumental factors.
引用
收藏
页码:168 / 177
页数:10
相关论文
共 21 条
  • [1] Standardisation of near-infrared spectrometric instruments: A review
    Bouveresse, E
    Massart, DL
    [J]. VIBRATIONAL SPECTROSCOPY, 1996, 11 (01) : 3 - 15
  • [2] BOX GEP, 1982, STAT EXPT
  • [3] Brown P. J., 1993, MEASUREMENT REGRESSI
  • [4] WAVELENGTH SELECTION IN MULTICOMPONENT NEAR-INFRARED CALIBRATION
    BROWN, PJ
    [J]. JOURNAL OF CHEMOMETRICS, 1992, 6 (03) : 151 - 161
  • [5] Brown SD, 1996, ANAL CHEM, V68, pR21, DOI 10.1021/a1960005x
  • [6] Infrared spectroscopy: Instrumental factors affecting the long-term validity of chemometric models
    Defernez, M
    Wilson, RH
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (07) : 1288 - 1294
  • [7] A STATISTICAL VIEW OF SOME CHEMOMETRICS REGRESSION TOOLS
    FRANK, IE
    FRIEDMAN, JH
    [J]. TECHNOMETRICS, 1993, 35 (02) : 109 - 135
  • [8] FRANKE JE, 1994, SPECTROCHIM ACTA, V50, P168
  • [9] Vibrational spectrometry for the assessment of active substance in metoprolol tablets: A comparison between transmission and diffuse reflectance near-infrared spectrometry
    Gottfries, J
    Depui, H
    Fransson, M
    Jongeneelen, M
    Josefson, M
    Langkilde, FW
    Witte, DT
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1996, 14 (11) : 1495 - 1503
  • [10] Analysis of a large structure-activity data set using recursive partitioning
    Hawkins, DM
    Young, SS
    Rusinko, A
    [J]. QUANTITATIVE STRUCTURE-ACTIVITY RELATIONSHIPS, 1997, 16 (04): : 296 - 302