An off-line strategy for constructing a patient-specific planning target volume in adaptive treatment process for prostate cancer

被引:278
作者
Yan, D [1 ]
Lockman, D [1 ]
Brabbins, D [1 ]
Tyburski, L [1 ]
Martinez, A [1 ]
机构
[1] William Beaumont Hosp, Dept Radiat Oncol, Royal Oak, MI 48073 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2000年 / 48卷 / 01期
关键词
prostate cancer treatment; off-line image feedback; patient-specific planning target volume; conventional and IMRT dose distributions; adaptive radiation therapy process;
D O I
10.1016/S0360-3016(00)00608-8
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To improve the efficacy of dose delivery and dose escalation for external beam radiotherapy of prostate cancer, an off-line strategy for constructing a patient-specific planning target volume is developed in the adaptive radiotherapy process using image feedback of target location and patient setup position. Materials and Methods: We hypothesize that a patient-specific confidence-limited planning target volume (cl-PTV), constructed using an initial sequence of daily measurements of internal target motion and patient setup error, exists and ensures that the clinical target volume (CTV) in the prostate cancer patient receives the prescribed dose within a predefined dose tolerance. A patient-specific bounding volume to correct for target location and compensate for target random motion was first constructed using the convex hull of the first k days of CT measurements. The bounding volume and the initial days of CT measurements were minimized based on a predefined dosimetric criterion. The hypothesis was tested using multiple daily CT images by mimicking the actual treatment of both conventional 4-field-box and intensity-modulated radiotherapy (IMRT) on each of 30 patients with prostate cancer. For each patient, a patient-specific setup margin was also applied to the bounding volume to form the final cl-PTV. This margin was determined using the random setup error predicted from the initial days of portal imaging measurements and the residuals after correcting for the systematic setup error. Results: The bounding volume constructed using daily CT measurements in the first week of treatment are adequate for the conventional beam delivery to achieve maximum dose reduction in the CTV of 2% or less of the prescription dose, for at least 80% of patients (p = 0.08), and 4.5% or less for 95% of patients (p = 0.1). However, for IMRT delivery, 2 weeks of daily CT measurements are required to achieve a similar level of the dosimetric criterion, otherwise the maximum dose reduction of 7%, on average, in the CTV is expected. Furthermore, the patient-specific setup margin required for the IMRT treatment is at least twice larger than that for the conventional treatment, to maintain the same dosimetric criterion. As compared to the conventional PTV, the volume of cl-PTV is significantly reduced, while maintaining the same dosimetric criterion. Conclusion: The cl-PTV for prostate treatment can be constructed within the first week of treatment using the feedback of imaging measurements. The cl-PTV has the capability to exclude the systematic variation and compensate for the patient-specific random variation on target location and patient setup position. This implies that in the current off-line image feedback adaptive treatment process, a single plan modification can be performed within the second week of treatment to improve the efficacy of dose delivery and dose escalation for external beam therapy of prostate cancer. (C) 2000 Elsevier Science Inc.
引用
收藏
页码:289 / 302
页数:14
相关论文
共 32 条
[21]   THE INFLUENCE OF RESPIRATION INDUCED MOTION OF THE KIDNEYS ON THE ACCURACY OF RADIOTHERAPY TREATMENT PLANNING, A MAGNETIC-RESONANCE-IMAGING STUDY [J].
MOERLAND, MA ;
VANDENBERGH, ACM ;
BHAGWANDIEN, R ;
JANSSEN, WM ;
BAKKER, CJG ;
LAGENDIJK, JJW ;
BATTERMANN, JJ .
RADIOTHERAPY AND ONCOLOGY, 1994, 30 (02) :150-154
[22]   Evaluation of changes in the size and location of the prostate, seminal vesicles, bladder, and rectum during a course of external beam radiation therapy [J].
Roeske, JC ;
Forman, JD ;
Mesina, CF ;
He, T ;
Pelizzari, CA ;
Fontenla, E ;
Vijayakumar, S ;
Chen, GTY .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1321-1329
[23]   ANALYSIS OF MOVEMENT OF INTRATHORACIC NEOPLASMS USING ULTRAFAST COMPUTERIZED-TOMOGRAPHY [J].
ROSS, CS ;
HUSSEY, DH ;
PENNINGTON, EC ;
STANFORD, W ;
DOORNBOS, JF .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (03) :671-677
[24]   Combined error of patient positioning variability and prostate motion uncertainty in 3D conformal radiotherapy of localized prostate cancer [J].
Rudat, V ;
Schraube, P ;
Oetzel, D ;
Zierhut, D ;
Flentje, M ;
Wannenmacher, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (05) :1027-1034
[25]   Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability [J].
Stroom, JC ;
de Boer, HCJ ;
Huizenga, H ;
Visser, AG .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 43 (04) :905-919
[26]   Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration [J].
vanHerk, M ;
Bruce, A ;
Kroes, APG ;
Shouman, T ;
Touw, A ;
Lebesque, JV .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1311-1320
[27]  
WU Y, 1999, MED PHYS, V26, P1137
[28]   A model to accumulate fractionated dose in a deforming organ [J].
Yan, D ;
Jaffray, DA ;
Wong, JW .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 44 (03) :665-675
[29]   Adaptive radiation therapy [J].
Yan, D ;
Vicini, F ;
Wong, J ;
Martinez, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (01) :123-132
[30]   Adaptive modification of treatment planning to minimize the deleterious effects of treatment setup errors [J].
Yan, D ;
Wong, J ;
Vicini, F ;
Michalski, J ;
Pan, C ;
Frazier, A ;
Horwitz, E ;
Martinez, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 38 (01) :197-206