Infections associated with medical devices - Pathogenesis, management and prophylaxis

被引:331
作者
von Eiff, C
Jansen, B
Kohnen, W
Becker, K
机构
[1] Univ Munster, Inst Med Microbiol, Hosp Clin, D-48149 Munster, Germany
[2] Johannes Gutenberg Univ Mainz, Dept Hyg & Environm Med, Mainz, Germany
关键词
D O I
10.2165/00003495-200565020-00003
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The insertion or implantation of foreign bodies has become an indispensable part in almost all fields of medicine. However, medical devices are associated with a definitive risk of bacterial and fungal infections. Foreign body-related infections (FBRIs), particularly catheter-related infections, significantly contribute to the increasing problem of nosocomial infections. While a variety of microorganisms may be involved as pathogens, staphylococci account for the majority of FBRIs. Their ability to adhere to materials and to promote formation of a biofilm is the most important feature of their pathogenicity. This biofilm on the surface of colonised foreign bodies is regarded as the biological correlative for the clinical experience with FBRI, that is, that the host defence mechanisms often seem to be unable to handle the infection and, in particular, to eliminate the microorganisms from the infected device. Since antibacterial chemotherapy is also frequently not able to cure these infections despite the use of antibacterials with proven in vitro activity, removal of implanted devices is often inevitable and has been standard clinical practice. However, in specific circumstances, such as infections of implanted medical devices with coagulase-negative staphylococci, a trial of salvage of the device may be justified. All FBRIs should be treated with antibacterials to which the pathogens have been shown to be susceptible. In addition to systemic antibacterial therapy, an intraluminal application of antibacterial agents, referred to as the 'antibiotic-lock' technique, should be considered to circumvent the need for removal, especially in patients with implanted long-term catheters. To reduce the incidence of intravascular catheter-related bloodstream infections, specific guidelines comprising both technological and nontechnological strategies for prevention have been established. Quality assurance, continuing education, choice of the catheter insertion site, hand hygiene and aseptic techniques are aspects of particular interest. Furthermore, all steps in the pathogenesis of biofilm formation may represent targets against which prevention strategies may be directed. Alteration of the foreign body material surface may lead to a change in specific and nonspecific interactions with micro-organisms and, thus, to a reduced microbial adherence. Medical devices made out of a material that would be antiadhesive or at least colonisation resistant would be the most suitable candidates to avoid colonisation and subsequent infection. Another concept for the prevention of FBRIs involves the impregnation of devices with various substances such as antibacterials, antiseptics and/or metals. Finally, further studies are needed to translate the knowledge on the mechanisms of biofilm formation into applicable therapeutic and preventive strategies.
引用
收藏
页码:179 / 214
页数:36
相关论文
共 277 条
[91]   A meta-analysis dealing with the effectiveness of chlorhexidine and silver-sulfadiazine impregnated central venous catheters [J].
Haxhe, JJ ;
D'Hoore, W .
JOURNAL OF HOSPITAL INFECTION, 1998, 40 (02) :166-168
[92]   NEW AND EMERGING YEAST PATHOGENS [J].
HAZEN, KC .
CLINICAL MICROBIOLOGY REVIEWS, 1995, 8 (04) :462-&
[93]   Influence of triple-lumen central venous catheters coated with chlorhexidine and silver sulfadiazine on the incidence of catheter-related bacteremia [J].
Heard, SO ;
Wagle, M ;
Vijayakumar, E ;
McLean, S ;
Brueggemann, A ;
Napolitano, LM ;
Edwards, LP ;
O'Connell, FM ;
Puyana, JC ;
Doern, GV .
ARCHIVES OF INTERNAL MEDICINE, 1998, 158 (01) :81-87
[94]   Molecular basis of intercellular adhesion in the biofilm-forming Staphylococcus epidermidis [J].
Heilmann, C ;
Schweitzer, O ;
Gerke, C ;
Vanittanakom, N ;
Mack, D ;
Gotz, F .
MOLECULAR MICROBIOLOGY, 1996, 20 (05) :1083-1091
[95]   Evidence for autolysin-mediated primary attachment of Staphylococcus epidermidis to a polystyrene surface [J].
Heilmann, C ;
Hussain, M ;
Peters, G ;
Gotz, F .
MOLECULAR MICROBIOLOGY, 1997, 24 (05) :1013-1024
[96]  
Herrmann M, 1997, CIRCULATION, V95, P814
[97]   Interaction of von Willebrand factor with Staphylococcus aureus [J].
Herrmann, M ;
Hartleib, J ;
Kehrel, B ;
Montgomery, RR ;
Sixma, JJ ;
Peters, G .
JOURNAL OF INFECTIOUS DISEASES, 1997, 176 (04) :984-991
[98]   FIBRONECTIN, FIBRINOGEN, AND LAMININ ACT AS MEDIATORS OF ADHERENCE OF CLINICAL STAPHYLOCOCCAL ISOLATES TO FOREIGN MATERIAL [J].
HERRMANN, M ;
VAUDAUX, PE ;
PITTET, D ;
AUCKENTHALER, R ;
LEW, PD ;
SCHUMACHERPERDREAU, F ;
PETERS, G ;
WALDVOGEL, FA .
JOURNAL OF INFECTIOUS DISEASES, 1988, 158 (04) :693-701
[99]   Salt-sensitive hypertension resulting from nitric oxide synthase inhibition is associated with loss of regulation of angiotensin II in the rat [J].
Hodge, G ;
Ye, VZC ;
Duggan, KA .
EXPERIMENTAL PHYSIOLOGY, 2002, 87 (01) :1-8
[100]   TRANSPARENT POLYURETHANE FILM AS AN INTRAVENOUS CATHETER DRESSING - A METAANALYSIS OF THE INFECTION RISKS [J].
HOFFMANN, KK ;
WEBER, DJ ;
SAMSA, GP ;
RUTALA, WA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1992, 267 (15) :2072-2076