Sensitive and Rapid Method for Amino Acid Quantitation in Malaria Biological Samples Using AccQ.Tag Ultra Performance Liquid Chromatography-Electrospray Ionization-MS/MS with Multiple Reaction Monitoring

被引:128
作者
Armenta, Jenny M. [1 ]
Cortes, Diego F. [1 ]
Pisciotta, John M. [2 ]
Shuman, Joel L. [1 ]
Blakeslee, Kenneth [3 ]
Rasoloson, Dominique [2 ]
Ogunbiyi, Oluwatosin [2 ]
Sullivan, David J., Jr. [2 ]
Shulaev, Vladimir [1 ,4 ,5 ]
机构
[1] Virginia Polytech Inst & State Univ, Virginia Bioinformat Inst, Blacksburg, VA 24061 USA
[2] Bloomberg Sch Publ Hlth, W Harry Feinstone Dept Mol Microbiol & Immunol, Baltimore, MD 21205 USA
[3] Waters Corp, Columbia, MD 21044 USA
[4] Virginia Polytech Inst & State Univ, Dept Hort, Blacksburg, VA 24061 USA
[5] Wake Forest Univ, Bowman Gray Sch Med, Dept Canc Biol, Winston Salem, NC 27157 USA
关键词
AUTOMATED PRECOLUMN DERIVATIZATION; TANDEM MASS-SPECTROMETRY; CAPILLARY-ELECTROPHORESIS; 6-AMINOQUINOLYL-N-HYDROXYSUCCINIMIDYL CARBAMATE; CHEMICAL DERIVATIZATION; FLUORESCENCE DETECTION; COLUMN DERIVATIZATION; PICOMOLE RANGE; DERIVATIVES; PHASE;
D O I
10.1021/ac901790q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An AccQ.Tag ultra performance liquid chromatography-electrospray ionization-tandem mass spectrometry (AccQ.Tag-UPLC-ESI-MS/MS) method for fast, reproducible, and sensitive amino acid quantitation in biological samples, particularly, the malaria parasite Plasmodium falciparum is presented. The Waters Acquity TQD UPLC/MS system equipped with a photodiode array (PDA) detector was used for amino acid separation and detection. The method was developed and validated using amino acid standard mixtures containing acidic, neutral, and basic amino acids. For MS analysis, the optimum cone voltage implemented, based on direct infusion analysis of a few selected AccQ.Tag amino acids with multiple reaction monitoring, varied from 29 to 39 V, whereas the collision energy varied from 15 to 35 V. Calibration curves were built using both internal and external standardization. Typically, a linear response for all amino acids was observed at concentration ranges of 3 x 10(-3)-25 pmol/mu L. For some amino acids, concentration limits of detection were as low as 1.65 fmol. The coefficients of variation for retention times were within the range of 0.08-1.08%. The coefficients of variation for amino acid quantitation, determined from triplicate UPLC-MS/MS runs, were below 8% on the averaged. The developed AccQ.Tag-UPL-GESI-MS/MS method revealed good technical and biological reproducibility when applied to P. falciparum and human red blood cells samples. This study should provide a valuable insight into the performance of UPLC-ESI-MS/MS for amino acid quantitation using AccQ.Tag derivatization.
引用
收藏
页码:548 / 558
页数:11
相关论文
共 49 条
[21]   Determination of biogenic amines by capillary electrophoresis [J].
Kovács, A ;
Simon-Sarkadi, L ;
Ganzler, K .
JOURNAL OF CHROMATOGRAPHY A, 1999, 836 (02) :305-313
[22]   New aspects of the simultaneous analysis of amino acids and amines as their o-phthaldialdehyde derivatives by high-performance liquid chromatography -: Analysis of wine, beer and vinegar [J].
Kutlán, D ;
Molnár-Perl, I .
JOURNAL OF CHROMATOGRAPHY A, 2003, 987 (1-2) :311-322
[23]   Proline-coated column for the capillary electrochromatographic separation of amino acids by in-column derivatization [J].
Lin, CC ;
Liu, CY .
ELECTROPHORESIS, 2004, 25 (18-19) :3216-3223
[24]   MEASUREMENT OF FREE AMINO-ACID LEVELS IN ULTRAFILTRATES OF BLOOD-PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH AUTOMATIC PRECOLUMN DERIVATIZATION [J].
LIU, H ;
WORTHEN, HG .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 579 (02) :215-224
[25]   COMPARISON OF REVERSE-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHODS FOR PRECOLUMN-DERIVATIZED AMINO-ACIDS [J].
MCCLUNG, G ;
FRANKENBERGER, WT .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1988, 11 (03) :613-646
[26]   Application of liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the analysis of stable isotope enrichments of phenylalanine and tyrosine [J].
Meesters, Roland J. W. ;
Wolfe, Robert R. ;
Deutz, Nicolaas E. P. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (1-2) :43-49
[27]   CE/electrospray ionization-MS analysis of underivatized D/L-amino acids and several small neurotransmitters at attomole levels through the use of 18-crown-6-tetracarboxylic acid as a complexation reagent/background electrolyte [J].
Moini, M ;
Schultz, CL ;
Mahmood, H .
ANALYTICAL CHEMISTRY, 2003, 75 (22) :6282-6287
[28]   Quantitation of amino acids and amines in the same matrix by high-performance liquid chromatography, either simultaneously or separately [J].
Molnár-Perl, I .
JOURNAL OF CHROMATOGRAPHY A, 2003, 987 (1-2) :291-309
[29]   Direct tandem mass spectrometric analysis of amino acids in dried blood spots without chemical derivatization for neonatal screening [J].
Nagy, K ;
Takáts, Z ;
Pollreisz, F ;
Szabó, T ;
Vékey, K .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (09) :983-990
[30]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PHENYLTHIOCARBAMYL DERIVATIVES OF AMINO-ACIDS AND SIDE-CHAIN DERIVATIZED AMINO-ACIDS [J].
OHARE, MMT ;
TORTORA, O ;
GETHER, U ;
NIELSEN, HV ;
SCHWARTZ, TW .