Dynamic helical CT of the abdomen: Prospective comparison of pre- and postprandial contrast enhancement

被引:17
作者
Sheafor, DH [1 ]
Keogan, MT [1 ]
DeLong, DM [1 ]
Nelson, RC [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
关键词
abdomen; CT; computed tomography (CT); contrast enhancement; helical;
D O I
10.1148/radiology.206.2.9457186
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To investigate effects of a liquid meal on contrast material enhancement at dynamic helical computed tomography (CT). MATERIALS AND METHODS: Twenty healthy, fasting subjects underwent intravenous injection of nonionic contrast material at 4 mL/sec. Axial CT sections were obtained at a single level 15 seconds after injection, then every 5 seconds for 2 minutes. This protocol was repeated 1 week later, after ingestion of a 360-calorie liquid meal. Hepatic, splenic, and aortic attenuation were measured before and after contrast material administration. Peak enhancement level, time to peak enhancement slope of hepatic enhancement, and hepatic splenic, and aortic enhancement ratios were determined. RESULTS: Postprandial time to peak enhancement was 4.4 seconds earlier than preprandial (59.6 seconds +/- 9.0 [1 standard deviation] vs 64.0 seconds +/- 9.5; P < .02). No differences in maximum attenuation were found (P >.27). Postprandial maximum slope of hepatic enhancement and temporal and quantitative enhancement characteristics in aorta and spleen did not significantly differ. Postprandial hepatic-to-splenic enhancement ratios increased (P = .04), and aortic-to-hepatic ratios decreased (P = .01). Aortic-to-splenic ratios did not differ (P = .45). CONCLUSION: A liquid meal before intravenous injection of contrast material produces more rapid peak hepatic enhancement, with slightly increased relative hepatic enhancement. A patient's dietary status, however, should not influence the CT protocol.
引用
收藏
页码:359 / 363
页数:5
相关论文
共 32 条
[11]   HEPATIC VASCULAR BED [J].
GREENWAY, CV ;
STARK, RD .
PHYSIOLOGICAL REVIEWS, 1971, 51 (01) :23-+
[12]   DYNAMIC CONTRAST-ENHANCED CT OF THE LIVER - COMPARISON OF CONTRAST-MEDIUM INJECTION RATES AND UNIPHASIC AND BIPHASIC INJECTION PROTOCOLS [J].
HEIKEN, JP ;
BRINK, JA ;
MCCLENNAN, BL ;
SAGEL, SS ;
FORMAN, HP ;
DICROCE, J .
RADIOLOGY, 1993, 187 (02) :327-331
[13]   EFFECT OF INCORPORATING FAT INTO A LIQUID TEST MEAL ON THE RELATION BETWEEN INTRAGASTRIC DISTRIBUTION AND GASTRIC-EMPTYING IN HUMAN VOLUNTEERS [J].
HOUGHTON, LA ;
MANGNALL, YF ;
READ, NW .
GUT, 1990, 31 (11) :1226-1229
[14]   Effects of a liquid meal on contrast-enhanced CT of the liver [J].
Irie, T ;
Kusano, S .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (04) :1023-1024
[15]   DYNAMIC CONTRAST ENHANCEMENT OF THE UPPER ABDOMEN - EFFECT OF CONTRAST-MEDIUM AND BODY-WEIGHT [J].
KORMANO, M ;
PARTANEN, K ;
SOIMAKALLIO, S ;
KIVIMAKI, T .
INVESTIGATIVE RADIOLOGY, 1983, 18 (04) :364-367
[16]   DUPLEX ULTRASOUND MEASUREMENT OF CHANGES IN MESENTERIC FLOW VELOCITY WITH PHARMACOLOGIC AND PHYSIOLOGIC ALTERATION OF INTESTINAL BLOOD-FLOW IN MAN [J].
LILLY, MP ;
HARWARD, TRS ;
FLINN, WR ;
BLACKBURN, DR ;
ASTLEFORD, PM ;
YAO, JST .
JOURNAL OF VASCULAR SURGERY, 1989, 9 (01) :18-25
[17]   ASSESSING THE EFFECTIVENESS OF X-RAY CONTRAST-MEDIA FOR ABDOMINAL COMPUTED TOMOGRAPHIC EXAMINATIONS - COMPARISON OF 4 LOW-OSMOLALITY AGENTS [J].
MARTIBONMATI, L ;
RONCHERAOMS, CL ;
ESPINOS, MA ;
JORDAN, Y ;
LUCAS, A .
JOURNAL OF CLINICAL PHARMACY AND THERAPEUTICS, 1995, 20 (02) :75-81
[18]   HEPATIC DYNAMIC SEQUENTIAL CT - SECTION ENHANCEMENT PROFILES WITH A BOLUS OF IONIC AND NONIONIC CONTRAST AGENTS [J].
NELSON, RC ;
MOYERS, JH ;
CHEZMAR, JL ;
HOEL, MJ ;
JONES, EC ;
PETERSON, JE ;
CORK, RD ;
BERNARDINO, ME .
RADIOLOGY, 1991, 178 (02) :499-502
[19]  
NORRYD C, 1975, ACTA CHIR SCAND, V141, P197
[20]   EFFECTS OF FOOD-INTAKE AND VARIOUS EXTRINSIC HORMONES ON PORTAL BLOOD-FLOW IN PATIENTS WITH LIVER-CIRRHOSIS DEMONSTRATED BY PULSED DOPPLER WITH THE OCTOSON [J].
OKAZAKI, K ;
MIYAZAKI, M ;
ONISHI, S ;
ITO, K .
SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1986, 21 (09) :1029-1038