Chromatographic determination of 8-oxo-7,8-dihydro-2′-deoxyguanosine in cellular DNA:: A validation study

被引:11
作者
Duez, P [1 ]
Helson, M [1 ]
Some, TI [1 ]
Dubois, J [1 ]
Hanocq, M [1 ]
机构
[1] Free Univ Brussels, Inst Pharm, Lab Bioanalyt Chem Toxicol & Appl Phys Chem, B-1050 Brussels, Belgium
关键词
biomarker; analytical validation; 8-oxo-dG; 8-OH-dG; oxidative stress; DNA damage;
D O I
10.1080/10715760000301411
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Although a series of biomarkers are widely used for the estimation of oxidative damage to biomolecules, validations of the analytical methods have seldom been presented. Formal validation, that is the study of the analytical performances of a method, is however recognized as the best safeguard against the generation and publication of data with low reliability. Classical validation parameters were investigated for the determination of an oxidative stress biomarker, 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxo-dG) in cellular DNA, by high-performance liquid chromatography coupled to amperometric detection (HPLC-EC); this modified base is increasingly considered as a marker of oxidative damage to DNA, but many questions are still raised on the analytical methods in use. Upon a rigorous statistical evaluation of the quality criteria currently required for assays in biological media, including selectivity, Linearity, accuracy, repeatability, sensitivity, limits of detection and quantification, ruggedness and storage at different stop points in the procedure, the HPLC-EC assay method is found mostly reliable. The present validation attempt demonstrates that (i) the HPLC-EC assay of 8-oxo-dG provides consistent data allowing to reliably detect an increase of this biomarker in cellular DNA; (ii) a harsh oxidative stress does not hinder the enzymatic digestion of DNA by nuclease pi; and (iii) the analytical results must be expressed relative to the internal standard dG which significantly improves both repeatability and sensitivity. Whereas the described assay minimizes the artifactual production of the analyte from processing and storage, this cannot be totally ruled out; the true 8-oxo-dG base levels still lack a definitive assay method, which remains a considerable analytical challenge and the object of controversy.
引用
收藏
页码:243 / 260
页数:18
相关论文
共 64 条
[41]  
MAIDT ML, 1996, FREE RADICALS PRACTI, P201
[42]   Gel electrophoretic detection of 7,8-dihydro-8-oxoguanine and 7,8-dihydro-8-oxoadenine via oxidation by Ir(IV) [J].
Muller, JG ;
Duarte, V ;
Hickerson, RP ;
Burrows, CJ .
NUCLEIC ACIDS RESEARCH, 1998, 26 (09) :2247-2249
[43]   QUANTITATIVE IMMUNOANALYSIS OF PROMUTAGENIC 8-HYDROXY-2'-DEOXYGUANOSINE IN OXIDIZED DNA [J].
MUSARRAT, J ;
WANI, AA .
CARCINOGENESIS, 1994, 15 (09) :2037-2043
[44]   IMPROVED GENOMIC NUCLEAR-DNA EXTRACTION FOR 8-HYDROXYDEOXYGUANOSINE ANALYSIS OF SMALL AMOUNTS OF RAT-LIVER TISSUE [J].
NAKAE, D ;
MIZUMOTO, Y ;
KOBAYASHI, E ;
NOGUCHI, O ;
KONISHI, Y .
CANCER LETTERS, 1995, 97 (02) :233-239
[45]   Determination of 8-hydroxydeoxyguanosine in human cells under oxygen-free conditions [J].
Nakajima, M ;
Takeuchi, T ;
Morimoto, K .
CARCINOGENESIS, 1996, 17 (04) :787-791
[46]  
*NCCLS, 1992, NCCLS EV PROT SC1 B
[47]  
NIEHLS P, 1997, ENV HLTH PERSPECTIVE, V105, P1291
[48]   DETECTION OF DNA ADDUCTS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
PARK, JW ;
CUNDY, KC ;
AMES, BN .
CARCINOGENESIS, 1989, 10 (05) :827-832
[49]   Determination of steady-state levels of oxidative DNA base modifications in mammalian cells by means of repair endonucleases [J].
Pflaum, M ;
Will, O ;
Epe, B .
CARCINOGENESIS, 1997, 18 (11) :2225-2231
[50]   MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY OF 8-OXOGUANINE AND OTHER BASES OF DNA [J].
POON, KW ;
MISTRY, N ;
PODMORE, ID ;
EVANS, MD ;
HERBERT, KE ;
LUNEC, J .
BIOCHEMICAL SOCIETY TRANSACTIONS, 1995, 23 (03) :S433-S433