Immobilization of a catalytic DNA molecular beacon on au for Pb(II) detection

被引:111
作者
Swearingen, CB
Wernette, DP
Cropek, DM
Lu, Y
Sweedler, JV
Bohn, PW
机构
[1] Univ Illinois, Beckman Inst Adv Sci & Technol, Urbana, IL 61801 USA
[2] Univ Illinois, Dept Chem, Urbana, IL 61801 USA
[3] Construct Engn Res Lab, Champaign, IL 61822 USA
关键词
D O I
10.1021/ac0401016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A Pb(II)-specific DNAzyme fluorescent sensor has been modified with a thiol moiety in order to immobilize it on a An surface. Self-assembly of the DNAzyme is accomplished by first adsorbing the single-thiolated enzyme strand (HS-17E-Dy) followed by adsorption of mercapto-hexanol, which serves to displace any Au-N interactions and ensure that DNA is bound only through the S-headgroup. The preformed self-assembled monolayer is then hybridized with the complementary fluorophore-containing substrate strand (17DS-F1). Upon reaction with Pb(II), the substrate strand is cleaved, releasing a fluorescent fragment for detection. Fluorescence intensity may be correlated with original Pb(II) concentration, and a linear calibration was obtained over nearly four decades: 10 muM greater than or equal to [Pb(II)] > 1 nM. The immobilized DNAzyme is a robust system; it may be regenerated after cleavage, allowing multiple sensing cycles. In addition, drying of fully assembled DNAzyme before reaction with Pb(II) does not significantly affect analytical performance. These results demonstrate that, in comparison with solution-based schemes, immobilization of the DNAzyme sensor onto a An surface lowers the detection limit (from 10 to 1 nM), maintains activity and specificity, and allows sensor regeneration and long-term storage. Realization of Pb(II) detection through an immobilized DNAzyme is the first important step toward creation of a stand-alone, portable Pb(II) detection device such as those immobilizing DNAzyme recognition motifs in the nanofluidic pores of a microfluidic-nanofluidic hybrid multilayer device.
引用
收藏
页码:442 / 448
页数:7
相关论文
共 54 条
[21]   Hybrid three-dimensional nanofluidic/microfluidic devices using molecular gates [J].
Kuo, TC ;
Cannon, DM ;
Shannon, MA ;
Bohn, PW ;
Sweedler, JV .
SENSORS AND ACTUATORS A-PHYSICAL, 2003, 102 (03) :223-233
[22]   Manipulating molecular transport through nanoporous membranes by control of electrokinetic flow: Effect of surface charge density and debye length [J].
Kuo, TC ;
Sloan, LA ;
Sweedler, JV ;
Bohn, PW .
LANGMUIR, 2001, 17 (20) :6298-6303
[23]   Using self-assembly to control the structure of DNA monolayers on gold: A neutron reflectivity study [J].
Levicky, R ;
Herne, TM ;
Tarlov, MJ ;
Satija, SK .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1998, 120 (38) :9787-9792
[24]   A highly sensitive and selective catalytic DNA biosensor for lead ions [J].
Li, J ;
Lu, Y .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2000, 122 (42) :10466-10467
[25]   In vitro selection and characterization of a highly efficient Zn(II)-dependent RNA-cleaving deoxyribozyme [J].
Li, J ;
Zheng, WC ;
Kwon, AH ;
Lu, Y .
NUCLEIC ACIDS RESEARCH, 2000, 28 (02) :481-488
[26]   Deoxyribozymes: new players in the ancient game of biocatalysis [J].
Li, YF ;
Breaker, RR .
CURRENT OPINION IN STRUCTURAL BIOLOGY, 1999, 9 (03) :315-323
[27]   Determination of trace copper, lead, cadmium, and iron in environmental and biological samples by flame atomic absorption spectrometry coupled to flow injection on-line coprecipitation preconcentration using DDTC-nickel as coprecipitate carrier [J].
Liu, JS ;
Chen, HW ;
Mao, XQ ;
Jin, X .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2000, 76 (04) :267-282
[28]   A colorimetric lead biosensor using DNAzyme-directed assembly of gold nanoparticles [J].
Liu, JW ;
Lu, Y .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (22) :6642-6643
[29]   Colorimetric biosensors based on DNAzyme-assembled gold nanoparticles [J].
Liu, JW ;
Lu, Y .
JOURNAL OF FLUORESCENCE, 2004, 14 (04) :343-354
[30]   Improving fluorescent DNAzyme biosensors by combining inter- and intramolecular quenchers [J].
Liu, JW ;
Lu, Y .
ANALYTICAL CHEMISTRY, 2003, 75 (23) :6666-6672