Removal of a mirror image and enhancement of the signal-to-noise ratio in Fourier-domain optical coherence tomography using an electro-optic phase modulator

被引:156
作者
Zhang, J [1 ]
Nelson, JS
Chen, ZP
机构
[1] Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA
[2] Univ Calif Irvine, Ctr Biomed Engn, Irvine, CA 92612 USA
关键词
D O I
10.1364/OL.30.000147
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A novel swept-laser-based Fourier-domain optical coherence tomography system using an electro-optic phase modulator was demonstrated. The imaging range was doubled by cancellation of the mirror image. The elimination of low-frequency noises resulting from de and autocorrelation terms increased the sensitivity by 20 dB. (C) 2005 Optical Society of America.
引用
收藏
页码:147 / 149
页数:3
相关论文
共 14 条
[1]   Ultrahigh-resolution high-speed retinal imaging using spectral-domain optical coherence tomography [J].
Cense, B ;
Nassif, NA ;
Chen, T ;
Pierce, M ;
Yun, SH ;
Park, BH ;
Bouma, BE ;
Tearney, GJ ;
de Boer, JF .
OPTICS EXPRESS, 2004, 12 (11) :2435-2447
[2]   Instantaneous quadrature low-coherence interferometry with 3 x 3 fiber-optic couplers [J].
Choma, MA ;
Yang, CH ;
Izatt, JA .
OPTICS LETTERS, 2003, 28 (22) :2162-2164
[3]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[4]   Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069
[5]   MEASUREMENT OF INTRAOCULAR DISTANCES BY BACKSCATTERING SPECTRAL INTERFEROMETRY [J].
FERCHER, AF ;
HITZENBERGER, CK ;
KAMP, G ;
ELZAIAT, SY .
OPTICS COMMUNICATIONS, 1995, 117 (1-2) :43-48
[6]  
Häusler G, 1998, J BIOMED OPT, V3, P21, DOI 10.1117/1.429899
[7]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[8]   Performance of fourier domain vs. time domain optical coherence tomography [J].
Leitgeb, R ;
Hitzenberger, CK ;
Fercher, AF .
OPTICS EXPRESS, 2003, 11 (08) :889-894
[9]   Phase-shifting algorithm to achieve high-speed long-depth-range probing by frequency-domain optical coherence tomography [J].
Leitgeb, RA ;
Hitzenberger, CK ;
Fercher, AF ;
Bajraszewski, T .
OPTICS LETTERS, 2003, 28 (22) :2201-2203
[10]   A SIMPLE INTENSITY NOISE-REDUCTION TECHNIQUE FOR OPTICAL LOW-COHERENCE REFLECTOMETRY [J].
SORIN, WV ;
BANEY, DM .
IEEE PHOTONICS TECHNOLOGY LETTERS, 1992, 4 (12) :1404-1406