The optimisation of lumbar spine AP radiography using a realistic computer model

被引:4
作者
Dance, DR
McVey, GH
Sandborg, M
Carlsson, GA
Verdun, FR
机构
[1] Royal Marsden NHS Trust, Dept Phys, London SW3 6JJ, England
[2] Linkoping Univ, Dept Radiat Phys, IMV, Fac Hlth Sci, SE-58185 Linkoping, Sweden
[3] Inst Appl Radiophys, CH-1007 Lausanne, Switzerland
关键词
D O I
10.1093/oxfordjournals.rpd.a033120
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A Monte Carlo computer program has been developed to model X ray imaging systems realistically using an adult voxel phantom. Image quality is quantified in terms of contrast and signal-to-noise ratio (SNR) for six important anatomical details chosen in accordance with recent European guidelines. The program has been used to study and optimise lumbar spine (LS) radiographic systems. As an example, the effect of tube potential on contrast, SNR and effective dose for the LS AP examination is demonstrated. Optimisation involves comparison of performance with that of a reference system. Configurations (tube potential, grid and screen-him) have been found which approximately match the reference image quality, but at lower effective dose. Various configurations give good performance. Some result in significant dose reduction. For LS AP 400 and 600 speed-class systems, dose savings of 21% and 34% are achievable. The model is thus a powerful tool for system optimisation.
引用
收藏
页码:207 / 210
页数:4
相关论文
共 11 条
[1]  
ALMEN A, 1998, 9801 LUGUPORP
[2]  
[Anonymous], 1991, ANN ICRP, V60
[3]  
Carmichael J. H. E., 1996, 16260 EUR EN
[4]   The use of carbon fibre material in radiographic cassettes: Estimation of the dose and contrast advantages [J].
Dance, DR ;
Lester, SA ;
Carlsson, GA ;
Sandborg, M ;
Persliden, J .
BRITISH JOURNAL OF RADIOLOGY, 1997, 70 (832) :383-390
[5]   Calibration and validation of a voxel phantom for use in the Monte Carlo modeling and optimisation of X-ray imaging systems [J].
Dance, DR ;
McVey, G ;
Sadborg, M ;
Persliden, J ;
Carlsson, GA .
MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 :548-559
[6]   A voxel phantom based Monte Carlo computer program for optimisation of chest and lumbar spine X ray imaging systems [J].
Sandborg, M ;
McVey, G ;
Dance, DR ;
Persliden, J ;
Carlsson, GA .
RADIATION PROTECTION DOSIMETRY, 2000, 90 (1-2) :105-108
[7]  
SANDBORG M, 1997, ULIRADR85SE
[8]  
SANDBORG M, 2000, ULIRADR85SE
[9]  
SANDBORG M, 1999, ULIRADR90SE
[10]  
Sanders Roger, 1994, Ultrasound Quarterly, V12, P167, DOI 10.1097/00013644-199412030-00002