Three-dimensional trace element analysis by confocal X-ray microfluorescence imaging

被引:187
作者
Vincze, L
Vekemans, B
Brenker, FE
Falkenberg, G
Rickers, K
Somogyi, A
Kersten, M
Adams, F
机构
[1] Univ Instelling Antwerp, MiTAC, B-2610 Antwerp, Belgium
[2] Univ Cologne, Inst Mineral & Geochem, D-50674 Cologne, Germany
[3] DESY, Hamburger Synchronstrahlungslabor, D-22607 Hamburg, Germany
[4] Geoforschzentrum Potsdam, Div 4 1, Potsdam, Germany
[5] European Synchrotron Radiat Facil, ID22, F-38043 Grenoble, France
[6] Johannes Gutenberg Univ Mainz, Inst Geosci, D-55099 Mainz, Germany
关键词
D O I
10.1021/ac049274l
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A three-dimensional (3D) variant of scanning micro X-ray fluorescence (XRF) is described and evaluated at the ID 18F instrument of the European Synchrotron Radiation Facility (ESRF). The method is based on confocal excitation/detection using a polycapillary half-lens in front of the energy-dispersive detector. The experimental arrangement represents a significant generalization of regular two-dimensional (2D) scanning micro-XRF and employs a detector half-lens whose focus coincides with that of the focused incoming beam. The detection volume defined by the intersection of the exciting beam and the energy-dependent acceptance of the polycapillary optics is 100350 mum(3). Minimum detection limits are sub-ppm, and sensitivities are comparable with regular scanning XRF. Next to the reduction of in-sample single/multiple scattering, the setup provides the possibility of sample depth scans with an energy-dependent resolution of 10-35mum in the energy range of 3-23 keV and the possibility of performing 3D-XRF analysis by simple XYZ linear scanning. This provides a suitable alternative to X-ray fluorescence tomography. The method is illustrated with results of the analysis of solid inclusions in diamond and fluid inclusions in quartz.
引用
收藏
页码:6786 / 6791
页数:6
相关论文
共 20 条
[1]   Exhumation of lower mantle inclusions in diamond: ATEM investigation of retrograde phase transitions, reactions and exsolution [J].
Brenker, FE ;
Stachel, T ;
Harris, JW .
EARTH AND PLANETARY SCIENCE LETTERS, 2002, 198 (1-2) :1-9
[2]   Polycapillary x-ray optics: manufacturing status, characterization and the future of the technology [J].
Gao, N ;
Ponomarev, IY .
X-RAY SPECTROMETRY, 2003, 32 (03) :186-194
[3]  
GIBSON WM, 1992, SPIE, V1736, P172
[4]   Internal elemental microanalysis combining x-ray fluorescence, Compton and transmission tomography [J].
Golosio, B ;
Simionovici, A ;
Somogyi, A ;
Lemelle, L ;
Chukalina, M ;
Brunetti, A .
JOURNAL OF APPLIED PHYSICS, 2003, 94 (01) :145-156
[5]  
HAVRILLA G, 2002, DENV XRAY C COL SPRI
[6]  
Janssens K. H. A., 2000, MICROSCOPIC XRAY FLU
[7]   A new 3D micro X-ray fluorescence analysis set-up - First archaeometric applications [J].
Kanngiesser, B ;
Malzer, W ;
Reiche, I .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2003, 211 (02) :259-264
[8]   Miniature ionization chamber detector developed for X-ray microprobe measurements [J].
Kocsis, M ;
Somogyi, A .
JOURNAL OF SYNCHROTRON RADIATION, 2003, 10 :187-190
[9]   Spectroscopic 2D-tomography: Residual pressure and strain around mineral inclusions in diamonds [J].
Nasdala, L ;
Brenker, FE ;
Glinnemann, J ;
Hofmeister, W ;
Gasparik, T ;
Harris, JW ;
Stachel, T ;
Reese, I .
EUROPEAN JOURNAL OF MINERALOGY, 2003, 15 (06) :931-935
[10]   A compilation of new and published major and trace element data for NIST SRM 610 and NIST SRM 612 glass reference materials [J].
Pearce, NJG ;
Perkins, WT ;
Westgate, JA ;
Gorton, MP ;
Jackson, SE ;
Neal, CR ;
Chenery, SP .
GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 1997, 21 (01) :115-144