Conducting elastomer surface texturing: a path to electrode spotting - Application to the biochip production

被引:24
作者
Marquette, CA [1 ]
Blum, LJ [1 ]
机构
[1] Univ Lyon 1, CNRS, UMR 5013, EMB2,Lab Genie Enzymat & Biomol, F-69622 Villeurbanne, France
关键词
biochip; conducting elastomer; DNA; electro-chemiluminescence; enzyme; immuno; microarray; PDMS;
D O I
10.1016/j.bios.2004.01.033
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A new active support for electro-chemiluminescent biochip preparation has been developed. This material was based on an original material composed of graphite modified polydimethyl siloxane (PDMS). The addressed inclusion of Sepharose beads at the surface of this elastomeric electrode generated interesting local high specific surface. The electrode was characterised by electrochemical (cyclic voltametry, chronoamperomatry) and imaging (scanning electron microscopy (SEM)) methods, and a surface area increase factor of 50 was found, linked to the texturing of the surface generated by the presence of the Sepharose beads. The consequence of this increase was shown to be a jump of the local electrochemical activity which induced a well defined and localised electro-chemiluminescent signal. The new material was used to design biochips based on the electro-chemiluminescent reaction of luminol with enzymatically produced hydrogen peroxide. Thus, when using beads bearing bio-molecules such nucleic acid or human IgG, in conjunction with glucose oxidas-labelled DNA or antibody, sensitive biochips could be obtained with detection limits of 10(11) and 10(10) molecules, respectively. Multi-parameter enzyme-based biochips could also be achieved by locally adsorbing, at the PDMS-graphite surface, either glucose oxidase, lactate oxidase or choline oxidase. Detection limits of 10 muM for lactate and choline and 20 muM for glucose were found, with detection ranging over two decades at least. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:197 / 203
页数:7
相关论文
共 19 条
[1]  
BARD AJ, 1996, ELECTROANALYTICAL CH, V19
[2]   Fabrication and surface characterization of DNA microarrays using amine- and thiol-terminated oligonucleotide probes [J].
Charles, PT ;
Vora, GJ ;
Andreadis, JD ;
Fortney, AJ ;
Meador, CE ;
Dulcey, CS ;
Stenger, DA .
LANGMUIR, 2003, 19 (05) :1586-1591
[3]   Platinum microelectrodes with unique high surface areas [J].
Elliott, JM ;
Birkin, PR ;
Bartlett, PN ;
Attard, GS .
LANGMUIR, 1999, 15 (22) :7411-7415
[4]   High-density fiber-optic genosensor microsphere array capable of zeptomole detection limits [J].
Epstein, JR ;
Lee, M ;
Walt, DR .
ANALYTICAL CHEMISTRY, 2002, 74 (08) :1836-1840
[5]   Construction and characterization of a nanowell electrode array [J].
Evans, U ;
Colavita, PE ;
Doescher, MS ;
Schiza, M ;
Myrick, ML .
NANO LETTERS, 2002, 2 (06) :641-645
[6]   Luminol electrochemiluminescence-based biosensor for total cholesterol determination in natural samples [J].
Marquette, CA ;
Ravaud, S ;
Blum, LJ .
ANALYTICAL LETTERS, 2000, 33 (09) :1779-1796
[7]   Direct immobilization in poly(dimethylsiloxane) for DNA, protein and enzyme luidic biochips [J].
Marquette, CA ;
Blum, LJ .
ANALYTICA CHIMICA ACTA, 2004, 506 (02) :127-132
[8]   Design of luminescent biochips based on enzyme, antibody, or DNA composite layers [J].
Marquette, CA ;
Thomas, D ;
Degiuli, A ;
Blum, LJ .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (05) :922-928
[9]   Impedance based DNA chip for direct Tm measurement [J].
Marquette, CA ;
Lawrence, I ;
Polychronakos, C ;
Lawrence, MF .
TALANTA, 2002, 56 (04) :763-768
[10]   Electrochemiluminescence of luminol for 2,4-D optical immunosensing in a flow injection analysis system [J].
Marquette, CA ;
Blum, LJ .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 51 (1-3) :100-106