摘要
The dual purpose of this study was, to evaluate the fracture rate of Ni-Ti rotary instruments when following a manual glide path and using stainless steel hand files before carrying out instrumentation by means of rotary files and, to compare the results in this study with those obtained in two previous analyses, in which the glide path technique was not used. A total of 208 canals obtained from a pool of freshly extracted human mandibular and maxillary molars was divided into three groups corresponding to; K3, ProFile and ProTaper. The coronal 2/3 of each tooth were used. In all three groups the apical portion of the samples was prepared with size 10-20 stainless steel K-type hand files. The apical stops were prepared using K3, ProFile and ProTaper rotary instruments. Logistic regression model analysis indicated that breakage was significantly associated with the angle of curvature of the canal (OR = 1.078; 95% Cl = 1.032-1.12; p = 0.001), and with the number of clinical uses (files used more than eight times broke more frequently that those used 1 or 2 times; OR: 22.686; 95% CI: 2.6-191.3; p = 0.004). The breakage rate obtained in the present study is significantly lower than in our previous studies, in which the angle of curvature was also greater than 30degrees and rotational speed a constant 350 rpm, but in which the canals were not first prepared with hand files (25/205 = 12% versus 16/61 = 26%, p = 0.007). Based on the results of this study, we recommend the use of stainless steel hand files to prepare the apical 1/3 of curved canals before introducing rotary files.
引用
收藏
页码:114 / 116
页数:3
相关论文
共 20 条
[1]  
Bryant ST, 1998, INT ENDOD J, V31, P275
[2]   Comparison of fracture rate, deformation rate, and efficiency between rotary endodontic instruments driven at 150 rpm and 350 rpm [J].
Daugherty, DW ;
Gound, TG ;
Comer, TL .
JOURNAL OF ENDODONTICS, 2001, 27 (02) :93-95
[3]   A COMPARISON OF CANAL PREPARATION WITH NICKEL-TITANIUM AND STAINLESS-STEEL INSTRUMENTS [J].
ESPOSITO, PT ;
CUNNINGHAM, CJ .
JOURNAL OF ENDODONTICS, 1995, 21 (04) :173-176
[4]   Effect of rotational speed on nickel-titanium file distortion [J].
Gabel, WP ;
Hoen, M ;
Steiman, HR ;
Pink, FE ;
Dietz, R .
JOURNAL OF ENDODONTICS, 1999, 25 (11) :752-754
[5]  
Gambarini G, 2000, ENDOD DENT TRAUMATOL, V16, P95
[6]   A COMPARISON OF ROOT-CANAL PREPARATIONS USING NI-TI HAND, NI-TI ENGINE-DRIVEN, AND K-FLEX ENDODONTIC INSTRUMENTS [J].
GLOSSON, CR ;
HALLER, RH ;
DOVE, SB ;
DELRIO, CE .
JOURNAL OF ENDODONTICS, 1995, 21 (03) :146-151
[7]   Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments [J].
Haïkel, Y ;
Serfaty, R ;
Bateman, G ;
Senger, B ;
Allemann, C .
JOURNAL OF ENDODONTICS, 1999, 25 (06) :434-440
[8]   Effect of rotational speed on root canal preparation with hero 642 rotary Ni-Ti instruments [J].
Karagöz-Küçükay, I ;
Ersev, H ;
Engin-Akkoca, E ;
Küçükay, S ;
Gürsoy, T .
JOURNAL OF ENDODONTICS, 2003, 29 (07) :447-449
[9]   Scanning electron microscope appearances of Lightspeed instruments used clinically: a pilot study [J].
Marending, M ;
Lutz, F ;
Barbakow, F .
INTERNATIONAL ENDODONTIC JOURNAL, 1998, 31 (01) :57-62
[10]   Factors influencing the fracture of nickel-titanium rotary instruments [J].
Martín, B ;
Zelada, G ;
Varela, P ;
Bahillo, JG ;
Magán, F ;
Ahn, S ;
Rodríguez, C .
INTERNATIONAL ENDODONTIC JOURNAL, 2003, 36 (04) :262-266