摘要
Gradual corrosion of stainless steel electrospray emitters under conditions of normal use generates surface irregularities that can promote electrical discharge. The increased emission current affects the electrochemical reactions associated with the spray process. When sampling the peptide A beta(1-40), this is manifest by oxidation of methionine at position 35 to methionine sulfoxide. The resultant mass shift and reduced sensitivity can adversely affect H/D exchange experiments. These effects can be avoided by adding a redox buffer or (preferably) by repolishing the emitter, especially to a rounded geometry.
引用
收藏
页码:2031 / 2036
页数:6
相关论文
共 30 条
[1]  
BROT N, 1991, BIOFACTORS, V3, P91
[2]   Practical implications of some recent studies in electrospray ionization fundamentals [J].
Cech, NB ;
Enke, CG .
MASS SPECTROMETRY REVIEWS, 2001, 20 (06) :362-387
[3]  
Celland WW, 1964, BIOCHEMISTRY-US, V3, P480
[4]   A triaxial probe for on-line proteolysis coupled with hydrogen/deuterium exchange-electrospray mass spectrometry [J].
Chen, Maolian ;
Cook, Kelsey D. ;
Kheterpal, Indu ;
Wetzel, Ronald .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2007, 18 (02) :208-217
[5]   MASS-SPECTROMETRIC IDENTIFICATION OF AMINO-ACID TRANSFORMATIONS DURING OXIDATION OF PEPTIDES AND PROTEINS - MODIFICATIONS OF METHIONINE AND TYROSINE [J].
CHOWDHURY, SK ;
ESHRAGHI, J ;
WOLFE, H ;
FORDE, D ;
HLAVAC, AG ;
JOHNSTON, D .
ANALYTICAL CHEMISTRY, 1995, 67 (02) :390-398
[6]   Reductive dehalogenation of monobromobimane by tris(2-carboxyethyl)phosphine [J].
Graham, DE ;
Harich, KC ;
White, RH .
ANALYTICAL BIOCHEMISTRY, 2003, 318 (02) :325-328
[7]   Detection and characterization of methionine oxidation in peptides by collision-induced dissociation and electron capture dissociation [J].
Guan, ZQ ;
Yates, NA ;
Bakhtiar, R .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2003, 14 (06) :605-613
[8]   The metal-catalyzed oxidation of methionine in peptides by Fenton systems involves two consecutive one-electron oxidation processes [J].
Hong, JY ;
Schöneich, C .
FREE RADICAL BIOLOGY AND MEDICINE, 2001, 31 (11) :1432-1441
[9]   Interaction between alpha and upsilon-crystallin, common to the eye of the Australian platypus, by radical probe mass spectrometry [J].
Issa, Sarnah ;
Downard, Kevin M. .
JOURNAL OF MASS SPECTROMETRY, 2006, 41 (10) :1298-1303
[10]  
KEBARLE P, 1997, ELECTROSPRAY IONIZAT, P3