Thin and flexible active electrodes with shield for capacitive electrocardiogram measurement

被引:48
作者
Lee, Seung Min [2 ,3 ]
Sim, Kyo Sik [3 ]
Kim, Ko Keun [3 ,4 ]
Lim, Yong Gyu [5 ]
Park, Kwang Suk [1 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Biomed Engn, Seoul, South Korea
[2] Seoul Natl Univ, Grad Program Bioengn, Seoul, South Korea
[3] Seoul Natl Univ, Adv Biometr Res Ctr, Seoul, South Korea
[4] Seoul Natl Univ, Interdisciplinary Program Med & Biol Engn, Seoul, South Korea
[5] Sangji Univ, Dept Oriental Biomed Engn, Wonjusi, Gangwondo, South Korea
关键词
Active electrode; Capacitive ECG; Flexible electrode; Unconstrained ECG measurement; SURFACE; INTERFERENCE; REDUCTION; CONTACT; BODY; BED;
D O I
10.1007/s11517-010-0597-y
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Capacitive electrocardiogram (ECG) measurement over clothing requires large electrodes that can remain in contact with curved body surfaces to increase the signal-to-noise ratio (SNR). In this article, we propose a new, thin, and flexible active electrode for use as a capacitive ECG measurement electrode. This electrode contains a shielding plate over its surface and it is extremely thin and can bend freely to cover larger body surfaces of the curve-shaped human torso. We evaluated the characteristics of flexible active electrodes under conditions of varying cloth thickness, electrode size, and contacting pressure. Electrodes of two sizes (45 and 12 cm(2)) were attached to a chest belt to measure the ECG from the human torso, and the results obtained for both the sizes were compared. Cloth thickness and electrode size showed a dominant effect on the SNR, whereas contacting pressure had almost no effect. The flexible active electrodes attached to chest belts wrapped closely and uniformly over the curved surface of the torso and SNR was increased with an increase in electrode size. Although the ECG signal became more distorted as the cloth thickness increased, the larger-sized flexible active electrode (45 cm(2)) showed less distortion than the smaller-sized one (12 cm(2)).
引用
收藏
页码:447 / 457
页数:11
相关论文
共 19 条
[1]  
ANDREONI G, 2000, ANN INT C IEEE EMBS
[2]  
[Anonymous], TXB MED PHYSL
[3]  
BAXTER LK, 1997, CAPACITIVE SENSORS D, P147
[4]   MONITORING OF ELECTROCARDIOGRAMS IN BED WITHOUT UTILIZING BODY-SURFACE ELECTRODES [J].
ISHIJIMA, M .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1993, 40 (06) :593-594
[5]   Novel electrode-skin interface for breast electrical impedance scanning [J].
Ji, Zhenyu ;
Dong, Xiuzhen ;
Shi, Xuetao ;
You, Fusheng ;
Fu, Feng ;
Liu, Ruigang .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2009, 47 (10) :1045-1052
[6]   ECG measurement on a chair without conductive contact [J].
Lim, YG ;
Kim, KK ;
Park, KS .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (05) :956-959
[7]   ECC recording on a bed during steep without direct skin-contact [J].
Lim, Yong Gyu ;
Kim, Ko Keun ;
Park, Kwang Suk .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (04) :718-725
[8]   CAPACITIVE ELECTROCARDIOGRAPHIC AND BIOELECTRIC ELECTRODES [J].
LOPEZ, A ;
RICHARDSON, PC .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1969, BM16 (01) :99-+
[9]  
NEUMAN MR, 1978, MED INSTRUMENTATION
[10]   Capacitive facial movement detection for human-computer interaction to click by frowning and lifting eyebrows Assistive technology [J].
Rantanen, Ville ;
Niemenlehto, Pekka-Henrik ;
Verho, Jarmo ;
Lekkala, Jukka .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2010, 48 (01) :39-47