Electrical Capacitance Volume Tomography: Design and Applications

被引:147
作者
Wang, Fei [1 ]
Marashdeh, Qussai [1 ]
Fan, Liang-Shih [1 ]
Warsito, Warsito [1 ]
机构
[1] Ohio State Univ, William G Lowrie Dept Chem & Biomol Engn, Columbus, OH 43210 USA
关键词
electrical capacitance volume tomography; ECT; ECVT; capacitance sensor; multi-phase flow; non-intrusive testing; process imaging; IMAGE-RECONSTRUCTION TECHNIQUE; OPTICAL-FIBER PROBE; FLUIDIZED-BED; PRESSURE-FLUCTUATIONS; GAS-LIQUID; ECT; BEHAVIOR; SYSTEMS; TIME; ALGORITHMS;
D O I
10.3390/s100301890
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This article reports recent advances and progress in the field of electrical capacitance volume tomography (ECVT). ECVT, developed from the two-dimensional electrical capacitance tomography (ECT), is a promising non-intrusive imaging technology that can provide real-time three-dimensional images of the sensing domain. Images are reconstructed from capacitance measurements acquired by electrodes placed on the outside boundary of the testing vessel. In this article, a review of progress on capacitance sensor design and applications to multi-phase flows is presented. The sensor shape, electrode configuration, and the number of electrodes that comprise three key elements of three-dimensional capacitance sensors are illustrated. The article also highlights applications of ECVT sensors on vessels of various sizes from 1 to 60 inches with complex geometries. Case studies are used to show the capability and validity of ECVT. The studies provide qualitative and quantitative real-time three-dimensional information of the measuring domain under study. Advantages of ECVT render it a favorable tool to be utilized for industrial applications and fundamental multi-phase flow research.
引用
收藏
页码:1890 / 1917
页数:28
相关论文
共 72 条
[51]  
WANG F, 1971, CHEM ENG SCI, V26, P923
[52]  
WANG F, 2009, P AICHE ANN M NASHV
[53]  
Wang F, 2009, ADV CHEM ENG, V37, P179, DOI 10.1016/S0065-2377(09)03705-3
[54]  
Wang LH, 2008, J FOOD DRUG ANAL, V16, P21
[55]   Study of gas-fluidization dynamics with laser-polarized 129Xe [J].
Wang, RP ;
Rosen, MS ;
Candela, D ;
Mair, RW ;
Walsworth, RL .
MAGNETIC RESONANCE IMAGING, 2005, 23 (02) :203-207
[56]   Porosity distribution in random packed columns by gamma ray tomography [J].
Wang, ZC ;
Afacan, A ;
Nandakumar, K ;
Chuang, KT .
CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2001, 40 (03) :209-219
[57]   Some comments on 'Spatial imaging with 3D capacitance measurements' [J].
Warsito, W. ;
Marashdeh, Q. ;
Fan, L. S. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2007, 18 (11) :3665-3667
[58]   Dynamics of spiral bubble plume motion in the entrance region of bubble columns and three-phase fluidized beds using 3D ECT [J].
Warsito, W ;
Fan, LS .
CHEMICAL ENGINEERING SCIENCE, 2005, 60 (22) :6073-6084
[59]   ECT imaging of three-phase fluidized bed based on three-phase capacitance model [J].
Warsito, W ;
Fan, LS .
CHEMICAL ENGINEERING SCIENCE, 2003, 58 (3-6) :823-832
[60]   Neural network multi-criteria optimization image reconstruction technique (NN-MOIRT) for linear and non-linear process tomography [J].
Warsito, W ;
Fan, LS .
CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2003, 42 (8-9) :663-674