Quantitative aspects in comprehensive two-dimensional gas chromatography

被引:30
作者
Kallio, Minna [1 ]
Hyotylainen, Tuulia [1 ]
机构
[1] Univ Helsinki, Dept Chem, Analyt Chem Lab, FI-00014 Helsinki, Finland
基金
芬兰科学院;
关键词
comprehensive two-dimensional gas chromatography; overloading; calibration; quantification; polycyclic aromatic hydrocarbons (PAHs);
D O I
10.1016/j.chroma.2007.03.020
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The effect of the amount of matrix compounds in comprehensive two-dimensional gas chromatographic (GC x GC) separation of polycyclic aromatic hydrocarbons (PAHs) was investigated. The second dimension column was overloaded by progressively increasing the matrix amount and the separation was evaluated by inspecting peak widths, asymmetries, resolution, retention times, peak areas and volumes of the target compounds. In quantitative analysis, two different calibration methods were tested for both raw sediment extracts and cleaned extracts, i.e. for extracts in which the matrix was removed by a liquid chromatographic clean-up step. The quality of the separation was not significantly disturbed in terms of peak width, asymmetry and resolution when the amount of matrix was increased. However, the depth of the valley between PAH and preceding matrix peak increased with an increase in matrix amount and the repeatabilities of retention times, peak areas and volumes decreased. In quantitative analysis, calibration by using areas had a tendency to underestimate the trace amounts of PAH, especially for the non-cleaned samples. In case of volume calibration, the most accurate results were obtained by external calibration for both cleaned and non-cleaned samples. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:228 / 235
页数:8
相关论文
共 16 条
[1]  
*AG TECHN, 2000, AG CHEM STAT UND YOU, P87
[2]  
*AG TECHN, 2000, AG CHEM STAT UND YOU, P251
[3]   Trace analysis of polychlorinated dibenzo-p-dioxins, dibenzofurans and WHO polychlorinated biphenyls in food using comprehensive two-dimensional gas chromatography with electron-capture detection [J].
Danielsson, C ;
Wiberg, K ;
Korytár, P ;
Bergek, S ;
Brinkman, UAT ;
Haglund, P .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1086 (1-2) :61-70
[4]  
Dolan JW, 2002, LC GC EUR, V15, P12
[5]  
HARRIS DC, 2003, QUANTITATIVE CHEM AN, P88
[6]   Overloading of the second-dimension column in comprehensive two-dimensional gas chromatography [J].
Harynuk, J ;
Górecki, T ;
de Zeeuw, J .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1071 (1-2) :21-27
[7]  
Hinshaw J.V., 2004, LC GC EUR, V17, P216
[8]   Comprehensive two-dimensional gas chromatography in the analysis of urban aerosols [J].
Kallio, M ;
Hyötyläinen, T ;
Lehtonen, M ;
Jussila, M ;
Hartonen, K ;
Shimmo, M ;
Riekkola, ML .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1019 (1-2) :251-260
[9]   Semi-rotating cryogenic modulator for comprehensive two-dimensional gas chromatography [J].
Kallio, M ;
Hyötyläinen, T ;
Jussila, M ;
Hartonen, K ;
Palonen, S ;
Shimmo, M ;
Riekkola, ML .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 375 (06) :725-731
[10]   Analysis of aromatic compounds in gasoline with flow-switching comprehensive two-dimensional gas chromatography [J].
Micyus, NJ ;
McCurry, JD ;
Seeley, JV .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1086 (1-2) :115-121