Determination of heterocyclic amines by liquid chromatography-quadrupole time-of-flight mass spectrometry

被引:34
作者
Barceló-Barrachina, E [1 ]
Moyano, E [1 ]
Galceran, MT [1 ]
机构
[1] Univ Barcelona, Dept Quim Analit, E-08028 Barcelona, Spain
关键词
heterocyclic amines;
D O I
10.1016/j.chroma.2004.08.068
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper discusses the applicability of coupling liquid chromatography (LC) to mass spectrometry (MS) using a time-of-flight (TOF) mass analyzer for the analysis of heterocyclic amines (HAs). Accurate mass measurement (<2 mDa) with both MS-MS and in-source CID MS-MS was carried out to confirm the elemental composition of some fragments previously reported. Some isobaric assignments (fragments containing N versus CH2 and NH3 versus CD2H) were distinguished by taking advantage of the resolution provided by the TOF mass analyzer. On the other hand, the LC-MS analysis of HAs in MS acquisition mode was also performed. Quality parameters of the method were established. The linearity range extended over three orders of magnitude, limits of detection were in the pg level and good short-term precision values (R.S.D., 1.2-8.0%) were obtained. The LC-ESI-TOF method was applied to the determination of HAs in a lyophilized meat extract and the results obtained were comparable to those given by MS-MS with triple quadrupole and ion trap instruments. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:409 / 418
页数:10
相关论文
共 27 条
[2]   Evaluation of different liquid chromatography-electrospray mass spectrometry systems for the analysis of heterocyclic amines [J].
Barceló-Barrachina, E ;
Moyano, E ;
Puignou, L ;
Galceran, MT .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1023 (01) :67-78
[3]   Preparation of a beef-extract as a laboratory reference material for the determination of heterocyclic amines [J].
Bermudo, E ;
Busquets, R ;
Barceló-Barrachina, E ;
Puignou, L ;
Santos, FJ ;
Galceran, MT .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 802 (01) :61-68
[4]   ISOLATION AND CHARACTERIZATION OF NEW MUTAGENS FROM FRIED GROUND-BEEF [J].
FELTON, JS ;
KNIZE, MG ;
WOOD, C ;
WUEBBLES, BJ ;
HEALY, SK ;
STUERMER, DH ;
BJELDANES, LF ;
KIMBLE, BJ ;
HATCH, FT .
CARCINOGENESIS, 1984, 5 (01) :95-102
[5]   Liquid chromatography/time-of-flight/mass spectrometry (LC/TOF/MS) for the analysis of emerging contaminants [J].
Ferrer, I ;
Thurman, EM .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2003, 22 (10) :750-756
[6]   Dual-micro-ESI source for precise mass determination on a quadrupole time-of-flight mass spectrometer for genomic and proteomic applications [J].
Flora, JW ;
Null, AP ;
Muddiman, DC .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (07) :538-546
[7]   Isolation by solid-phase extraction and liquid chromatographic determination of mutagenic amines in beef extracts [J].
Galceran, MT ;
Pais, P ;
Puignou, L .
JOURNAL OF CHROMATOGRAPHY A, 1996, 719 (01) :203-212
[8]   Coupling of a supercritical fluid chromatography system to a hybrid (Q-TOF 2) mass spectrometer: on-line accurate mass measurements [J].
Garzotti, M ;
Rovatti, L ;
Hamdan, M .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (14) :1187-1190
[9]   Quantitative analysis of mutagenic heterocyclic aromatic amines in cooked meat using liquid chromatography-atmospheric pressure chemical ionisation tandem mass spectrometry [J].
Guy, PA ;
Gremaud, E ;
Richoz, J ;
Turesky, RJ .
JOURNAL OF CHROMATOGRAPHY A, 2000, 883 (1-2) :89-102
[10]  
HARGRAVES WA, 1983, CANCER RES, V43, P1467